• 제목/요약/키워드: syringe type

검색결과 34건 처리시간 0.029초

부가 중합형 실리콘 인상재에서 발생하는 수고 기체가 경석고 표면에 미치는 영향 (COMPARISON OF STONE SURFACE POROSITIES CAUSED BY HYDROGEN GAS FROM ADDITION SILICONE IMPRESSION MATERIALS)

  • 유소정;이근우;김경남
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.349-362
    • /
    • 1996
  • To determine the factors to affect on stone surface porosities produced from hydrogen gas of additional silicone, both putty and syringe type of 7 commercially different additional silicone impression materials(Blend-A-Scon, Correct VPS, Exaflex, Express, Extrude, Provil, Reprosil) were chosen and NewFujirock(GC) was poured into the impressions of detail-reproducing test block at 1, 15, 30, 45, 60 minutes after the impression materials had set and 4 specimens were made for each pouring time, each type of impression material, and each consisency and So, 280 specimens were made in total. The number of surface porosities of same area($2826 mm^2$) which were typically caused by hydrogen gas using the stereoscope(X 7.5) by two observers. Comparison of putty-syringe type and among the impression materials are tested by Kruscal-Wallis method and Mann-Whitney method(p<0.05). The results are as follows. 1. The number of porosities decreased as the pouring time of stone was delayed on both putty and syringe type of additional silicone materials. 2. The putty type significantly produced more porosities than syringe type except for the group of Reprosil.(p<0.05). 3. In case of putty type, the number of porosities increased as following order. Reprosil / Blend-A-Scon and Provil / Correct VPS and Extrude / Express and Exaflex. 4. In case of syringe type, Blend-A-Scon and Extrude produced no porosity and Exaflex and Provil at 30 minites, but Express produced porosities even at 60 minutes and the most. Additional silicone impression material releases hydrogen gas, and that fact can make the resulting die stone model useless. So, to minimize these adverse effects, it is desirable not to expose putty type of additional silicone on critical impression surface because putty type has a tendency to produce more porosities than syringe type. And it is important to have sufficient time before pouring the stone on impression because porosities produce less as time passes after setting of impression material. Also, there are differences among 7 additional silicone impression materials, so it is desirable to choose adequate brand of additional silicone for good laboratory work.

  • PDF

앰플 및 1회용 주사용기에서의 미립자 혼입에 관한 비교연구 (Comparative Study of Particulate Contamination from Ampoule and Prefilled Syringe)

  • 심창구;한용해;권돈선
    • Journal of Pharmaceutical Investigation
    • /
    • 제21권3호
    • /
    • pp.155-160
    • /
    • 1991
  • Particulate is the foreign insoluble material in injectable solution inadvertently present in a given product. Considerable efforts have been made to avoid or minimize particulate contamination by pharmaceutical manufacturers during the production of parenteral products. Particulate contamination of the parenteral products can occur mainly during the opening (cutting) the container immediately before clinical use. In this study, particulate contamination generated during the opening process of ampoules (conventional type, 1-point and color-break ampoules) was compared with that of a prefilled injectable container (prefilled syringe). The particles were examined under a microscope after filtration of the total fluids in the containers. Particles having wide range of size distribution were found from all the ampoules tested. The contamination from the I-point ampoule and colorbreak ampoule was much less than from the conventional ampoule. Glass particles generated by cutting the glass-made ampoules seemed a principal source of the particulate contamination. The glass-partiaulte contamination could be improved substantially by replacing the ampoule containers with the prefilled syringe. Prefilled syringe, which can be used without any cutting process. did not generate particulates during the use. Therefore, it was concluded that prefilled syringe is most preferable container for the small volume parenteral (SVP) fluids in terms of particulate contamination.

  • PDF

이중모드 주사기형 약물자동주입장치의 개발에 관한 연구 (Development of the Dual Mode Syringe Type Infusion Pump)

  • 홍수용;엄기현;김익근;이경중;윤형로;김은기;엄대자
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.317-318
    • /
    • 1998
  • The purpose of this study is to design and develop the circuit of the dual mode syringe pump. Syringe pump is used in intensive care unit, delivery room, pediatric room, operating theater and other fields of hospital at present. Normally the syringe pump delivers one medicine in one case, but in case of intensive care unit, it is necessary to deliver more than two kinds of medicines at a time. Therefore we have designed dual mode syringe pump. We used RISC type microcontroller, PIC17C44 as master controller, and PIC16C73 as slave cpu using for the low power consumption. The performance of system is evaluated by analysis of the linearity and accuracy which is the most important factors in application. While the proposed system shows a acceptable linearity and accuracy, a further research about reducing the errorr should be done.

  • PDF

Syringe Connector를 이용하여 조영제를 자동 주입장치에 연결 시 분쇄물 혼입에 관한 연구 (A Study on the Mixing of Pulverization Matters when the Contrast Medium is connected to the Automatic Injection Device using the Syringe Connector)

  • 김현주;김지은;한유빈;최승현;강윤기;정유진;정민영;이후민
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.777-783
    • /
    • 2018
  • 고무화합물 형태로 구성된 조영제의 병에 Syringe Connector의 Spike를 연결 시 고무의 찢김 정도를 알아 보고 찢김 및 분쇄로 인한 합성고무의 혼입 유무와 분쇄된 합성고무가 검출 시 분쇄물의 크기를 실험을 통해 알아보고자 하였다. 그 결과 찢김 정도의 경우 Syringe Connector의 끝과 최초 접촉하는 앞면이 약 $3.14{\pm}0.04mm$로 뒷면 보다 많이 찢겼으며, 실험 대상인 10 병의 조영제에서 평균 7 개에서 15 개로 모두 분쇄물이 검출되었다. 검출된 분쇄물을 이용하여 크기를 측정한 결과 평균크기는 약 $7.89{\pm}0.31{\mu}m$이었다. 향 후 다양한 실험 및 분석방법을 통한 추가실험과 더불어 흡인된 분쇄물 차단을 위한 미세 필터타입 자동주입장치의 개발이 필요하며, 분쇄물 유입 시 치명적 사고를 대비하여 관련기관의 관심 또한 필요할 것으로 사료된다.

In-line Automatic Defect Repair System for TFT-LCD Production

  • Arai, Takeshi;Nakasu, Nobuaki;Yoshimura, Kazushi;Edamura, Tadao
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.202-205
    • /
    • 2009
  • An automated circuit repair system was developed for enhancing the yield of nondefective liquid crystal panels, focusing on the resist patterns on the circuit material layer of thin-film transistor (TFT) substrates prior to etching. The developed system has an advantage over the parallel conventional system: In the former, the repair conditions depend on the type of resist whereas in the latter, the repair parameters must be fine-tuned for each circuit material. The developed system consists of a resist pattern defect inspection system and a pattern repair system for short and open defects. The repair system performs fine corrections of abnormal areas of the resist pattern. The open-repair system is equipped with a syringe to dispense resist. To maintain a stable resist diameter, a thermal insulator was installed in the syringe system. As a result, the diameter of the dispensed resist became much more stable than when no thermal insulator was used. The resist diameter was kept within the target of $400{\pm}100{\mu}m$. Furthermore, a prototype system was constructed, and using a dummy pattern, it was confirmed that the system worked automatically and correctly.

MEMS 공정을 이용한 마이크로 액체 추력기 배열체 제작 (Fabrication of a liquid microthruster array by MEMS manufacturing process)

  • 허정무;권세진
    • 항공우주시스템공학회지
    • /
    • 제9권2호
    • /
    • pp.13-18
    • /
    • 2015
  • Micro planar type liquid propellant thruster was fabricated by MEMS manufacturing process for micro/nano satellites applications. 90 wt.% hydrogen peroxide was used as propellant and for propellant decomposition, Pt/Al2O3 was used as catalyst. Micro thruster structure was made by 5 photosensitive glasses patterned with thruster component profiles. Objective thrust was 50 mN and required hydrogen peroxide mass flow was 2.1 ml/min, which was supplied by syringe pump and teflon tube in experimental test. Performance test said that average steady thrust was approximately 30 mN, around 60% of objective thrust, and transient time was about 5 sec. It is estimated that extended response time was due to high thermal energy loss of micro scale thruster and low enthalpy input by propellant mass flow.

Effects of Foot-and-mouth Disease Vaccination Location and Injection Device on the Incidence of Site Lesions in Pork

  • Ko, Eun Young;Jung, Samooel;Jeong, Hyun Kyu;Han, Jeong Hee;Son, Jung Ho
    • 한국축산식품학회지
    • /
    • 제38권3호
    • /
    • pp.498-505
    • /
    • 2018
  • This study was aimed to investigate the effects of the type O foot-and-mouse disease vaccine (FMDV) on the incidence of abnormal meat such as granuloma or abscess formation at the injection site in pork and its associated economic losses. At 56 d of age, piglets were inoculated with FMDV by one of three administration routes: N-Neck (a conventional needle-syringe injection into the neck), N-Ham (a conventional needle-syringe injection into the ham), and Non-Neck (injection with a needle-free device into the neck). The injection sites were visually examined for the presence of a granuloma or abscess, and the incidence rate of abnormal meat was calculated. The gross weight of the portion of the pork carcasses condemned because of granuloma or abscess formation was measured and multiplied by the weekly sales price to calculate the total economic losses. After implementation of FMDV, the economic losses were approximately six times higher than before implementation. Granuloma or abscess formation was significantly higher in the N-Neck and Non-Neck groups, in which the vaccine was inoculated into the neck area, than in the N-Ham group (N-Neck and N-Ham vs Non-Neck, p<0.05). These results suggest that the incidence of lesions could be reduced if the ham route was used for vaccination.

말기 암성통증을 위한 Totally Implanted Port System; 문제점과 합병증 (Totally Implanted Port System for Terminal Cancer Pain; Problems and Complications)

  • 홍기혁
    • The Korean Journal of Pain
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 1992
  • The use of epidural narcotics to treat cancer pain was first described by Behar et al in 1979. More recently, a variety of implantable INDSs have been described for long-term intraspinal narcotic administration. Especially, among these systems INDS typeIII which is designed by Poletti et al is relatively low cost and less risk of infection, therefore this system has been widely accepted but the clinical experience is insufficient yet. 1, Problems, 1) thorough education of patients and care-givers about this system the method of drug delivery and the situations could be happen in using this system. 2) high cost of continuous drug delivery system 3) legal problems about morphine carry-out in the case of bolus infusion by syringe 1. Complications; 1) by morphine; Significant respiratory depression was not found in all 21cases. other morphine-related complications were occurred occasionally but improved within a few days by appropriate treatment. 2) by system, Blockage or leakage of catheter was occurred in 2cases and wound infection was occurred in 2cases and so reimplantation was done.

  • PDF

랩온어칩 내부 미세유동 제어를 위한 새로운 장치의 개발 및 적용 (Development of A New Device for Controlling Infinitesimal Flows inside a Lab-On-A-Chip and Its Practical Application)

  • 김보람;김국배;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2006
  • For controlling micro-flows inside a LOC (lab-on-a-chip) a syringe pump or an electronic device for EOF(electro-osmotic flow) have been used in general. However, these devices are so large and heavy that they are burdensome in the development of a portable micro-TAS (total analysis system). In this study, a new flow control system employing pressure chambers, digital switches and speed controllers was developed. This system could effectively control the micro-scale flows inside a LOC without any mechanical actuators or electronic devices We also checked the feasibility of this new control system by applying it to a LOC of micro-mixer type. Performance tests show that the developed control system has very good performance. Because the flow rate in LOC is controlled easily by throttling the speed controller, the flows in complicate microchannels network can be also controlled precisely.

  • PDF

고온로를 이용한 매연발생장치 (Soot Generation System Utilizing High-Temperature Furnace)

  • 조상환;박선호;남연우;최유열;이원남
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.55-58
    • /
    • 2013
  • A new soot particle generation system has been developed and tested. The soot generation system consists of two sections, a fuel supply and a soot production. In the fuel supply module, either liquid fuel precisely controlled by a syringe pump is mixed with preheated carrier gas and rapidly evaporated or gaseous fuel controlled by a MFC is diluted with dilution gas. The soot production module contains a heater that can raise the gas/fuel temperature up to $1400^{\circ}C$. The physical and chemical properties of produced soot particles depend on the type and concentration of fuel, the residence time, and temperature in the soot production section. The soot generation system will be utilized to produce well-defined soot particles for soot studies such as the evaluation of experimental sampling and analysis processes for the quantitative assessment of PM and BC from ships and the adverse health effects on pulmonary and cardiovascular systems of human body.

  • PDF