• 제목/요약/키워드: switching element

검색결과 295건 처리시간 0.023초

LED 조명의 안전회로설계 Type분석에 따른 최적설계 (The Optimum Design According to Type Analysis of the Safety Circuit Design)

  • 장인혁;김정호;임홍우;오근태;최연옥
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권4호
    • /
    • pp.331-337
    • /
    • 2016
  • Purpose: The purpose of this study is the analysis of the failure mechanisms effect of circuit design characteristics of the ballast for LED Lamp Methods: Recently, electronic circuit of ballasts for LED lamp are being occurred on various failure mechanisms (whiskers, ion migration, heat dissipation problem, switching element damage) because electronic ballast circuit design characteristics are becoming more and more diverse. Results: we analysis failure mechanisms that occurs in accordance with the circuit design characteristics The ballast for LED lamp were divided into three different types (Type A, Type B, Type C) considering circuit design characteristics (thermal design, PCB patten spacing, element material) and it was experimented in the acceleration test conditions ($85^{\circ}C$, 85% R.H). Conclusion: We confirmed that failure mechanism of the ballast for LED Lamp had occurred differently in accordance with the circuit design characteristics.

삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석 (Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch)

  • 정병익;최효상;박정일;조금배
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.

정보통신기기용 과도이상전압 고속도차단장치의 설계 및 제작 (Design and Fabrication of a High Speed Blocking Device of Transient Overvoltages for info-communication Facilities)

  • 길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.51-56
    • /
    • 1999
  • This paper presents a new transient overvoltage blocking device (TOBD) for info-communication facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, thehybrid type TOBD, which consists of a gas tube, avalanche diodes and junction typefield effect transistors (JFETs), was designed and fabricated. The TOBD differs from the conventional protection devices in configuration, and JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche dilde with low energy capacity are protected fromthe high current, and the TOBD has a very small input capacitance. From the performance test using combination surge generator, which can produce $1.2/50\mus\;4.2kV_{max}\; 8/20\mus\; 2.1kA_{max}$, it is confirmed that proposed TOBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

유한요소법으로 계산한 파라메타를 이용한 스위치드 릴럭턴스 모타의 해석 (Analysis of Switched Reluctance Motors using Parameters obtained by Finite Element Method)

  • 이준호;이상호;이기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.47-50
    • /
    • 1997
  • The FEM(Finite Element Method) can be used to analysis SRM(Switched Reluctance Motor) as it can account for the salient pole geometry of the stator and rotor and the nonlinear properties of the magnetic materials. However, FEM requirers a lot of computer memory and computing time because, the kind of SRM drivers is verity and the switching strategies are various for one SRM driver. In this paper we proposed the method of analysis of a SRM which results are similar to FEM and has very short computing time. The Inductance and torque for each phase current at each rotor position are calculated by using two-dimensional nonlinear FEM analysis. Using the look-up table of inductance and torque and the voltage equations of SRM we obtained the phase current and torque. To verify proposed algorithm, 3 phase 6/4 SRM is analysed and found a good agreement with FEM results. And computing time is about 1/1600 of the FEM analysis.

  • PDF

리니어 펄스 모터에서 치 형상과 기자력 불평형이 정추력 특성에 미치는 영향 (Effect of Tooth Shape and Unbalanced M.M.F on Static Thrust Force Characteristics of Linear Pulse Motor)

  • 이동주;이은웅;김성헌;김성종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.131-137
    • /
    • 2000
  • 2 phase 8 pole HB-type(flat-type) Linear Pulse Motor can be used as the high precision position actuator because of its many advantages (simple control circuit, high stiffness characteristics, etc). Also, using the microstep drive, its noise and vibration can be reduced considerably and positional resolution may be increased further. But, $20^{\circ}$tapered tooth shape to reduce the normal force have an much effect on the static thrust force characteristics. And, because of hybrid-type LPM, interaction between the permanent magnet and the excitation current have an effect on the various characteristics of LPM. Hence, in this paper, the effect of tooth shape on static thrust force characteristics was analyzed using the air gap permeance by finite element method. For analyzing the effect of unbalance between the m.m.f of permanent magnet and the m.m.f of excitation current, unbalanced m.m.f coefficient $\sigma$ were introduced with the permenace matrix and switching matrix.

  • PDF

PMWN-PZT계 압전세라믹의 압전 및 유전 특성 (Characteristics of Piezoelectric and Dielectric of PMWN-PZT Ceramics)

  • 홍종국;이종섭;채홍인;윤만순;정수현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2000
  • The properties of piezoelectric and dielectric for 0.05Pb(Mn$\_$0.4/W$\_$0.2/Nb$\_$0.4/)O$_3$ - 0.95PbZr$\_$x/Ti$\_$1-x/O$_3$ compositions have been investigated. In the composition of 0.05Pb(Mn$\_$0.4/W$\_$0.2/Nb$\_$0.4/)O$_3$ - 0.95PbZr$\_$0.51/Ti$\_$0.49/O$_3$, the values of k$\_$p/ and $\varepsilon$$\_$33/$\^$T// $\varepsilon$$\_$0/ are maximized, but Q$\_$m/ was minimized (k$\_$p/=56.5[%], Q$\_$m/=1130, d$\_$33/=258[pC/N], $\varepsilon$$\_$33/$\^$T// $\varepsilon$$\_$0/=1170). The grain size was suppressed and the uniformity of grain was improved at the 1100[˚C]. Also, we can see the dielectric constants variations between the before poling and after poling. This effect results from the effect(increase element of dielectric constants) between dipole switching and electrostriction inducing stress and dipole direction to the poling orientation(decrease element of dielectric constants). At x=0.51, we can find MPB(morphotropic phase boundary).

  • PDF

비대칭 브리지 컨버터를 고려한 6/4 스위치드 릴럭턴스 전동기의 유한요소 해석 (Finite Element Analysis considering Asymmetric Bridge Converter in 6/4 Switched Reluctance Motor)

  • 최재학;박재범;이승준;안병립;이주;김석태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.720-722
    • /
    • 2003
  • This paper Presents a design schemes to minimize torque ripple in 6/4 Switched Reluctance Motor (SRM) using transient Finite Element Analysis (FEA) in which the magnetic field is combined with a driving circuit. Pole arcs and switching angles are major design factors. If these design factors are considered independently, the enhancement of SRM Performance is restricted. Therefore, this paper proposes not only optimal combination of stator pole arc and rotor pole arc but also the turn-on and turn-off angles as a function of pole arcs. Especially, turn-on and turn-off angle are formulated from a voltage equation and feasible design ranges are suggested with variable speed.

  • PDF

스핀밸브형 거대자기저항 다층박막의 자기적 특성 및 미세구조에 관한 연구 (A study on the magnetic properties and microstructure of spin-valve type multilayer for giant magnetoresistance)

  • 노재철;이두현;이명신;윤대호;서수정
    • 한국결정성장학회지
    • /
    • 제8권1호
    • /
    • pp.73-82
    • /
    • 1998
  • 교환이방성이란 반강자성층과 강자성층의 이층막(bilayer)사이의 교환작용에 의해 발생하는 일방향 자기이방성을 말한다. 본 연구에서는 스퍼터링법으로 제작한 NiO/NiFe 이층막에서 발생하는 교환이방성에 대한 연구를 통하여 이를 스핀밸브형 거대자기저항 소자에 적용하고자 하였다. 먼저 NiO 증착조건 변화에 따른 NiO/NiFe 이층막의 특성변화를 살펴보았으며, 이를 통하여 NiO 증착중 Ar 압력 변화가 이층막의 교환이방성에 가장 중요한 인자임을 알수 있었다. 즉 Ar 압력이 낮을수록 교환이방성 특성이 더 우수하였다. 이러한 이층막 조건을 통하여 스핀밸브형 거대자기저항 다층막을 증착하였으며 그 결과 3.4%의 자기저항비와 0.25%/Oe의 민감도를 얻었다.

  • PDF

Optimal Design of High Frequency Transformer for 150W Class Module-Integrated Converter

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.288-294
    • /
    • 2015
  • Recently, the module-integrated converter has shown an interest in the photovoltaic generation system. In this system, the high frequency transformer should be compact and efficient. The proposed method is based on the correlation characteristic between the copper and core loss to minimize the loss of transformer. By sizing an effective cross-sectional area and window area of core, the amount of loss is minimized. This paper presents the design and analysis of high frequency transformer by using the 3D finite element model coupled with DC-DC converter circuit for more accurate analysis by considering the nonlinear voltage and current waveforms in converter circuit. The current waveform in each winding is realized by using the ideal DC voltage source and switching component. And, the thermal analysis is performed to satisfy the electrical and thermal design criteria.

The Effects of Management Traffic on the Local Call Processing Performance of ATM Switches Using Queue Network Models and Jackson's Theorem

  • Heo, Dong-Hyun;Chung, Sang-Wook;Lee, Gil-Haeng
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.34-40
    • /
    • 2003
  • This paper considers a TMN-based management system for the management of public ATM switching networks using a four-level hierarchical structure consisting of one network management system, several element management systems, and several agent-ATM switch pairs. Using Jackson's queuing model, we analyze the effects of one TMN command on the performance of the component ATM switch in processing local calls. The TMN command considered is the permanent virtual call connection. We analyze four performance measures of ATM switches- utilization, mean queue length and mean waiting time for the processor directly interfacing with the subscriber lines and trunks, and the call setup delay of the ATM switch- and compare the results with those from Jackson's queuing model.