• Title/Summary/Keyword: switch module

Search Result 225, Processing Time 0.024 seconds

A Study of Fabrication of RF Control System for Building Sunshade (건물 차양을 위한 RF제어 시스템 제작에 관한 연구)

  • Park, Jung-Cheul;Chu, Soon-Nam
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.149-157
    • /
    • 2014
  • This paper is based on the fabrication of wireless control system for the building shading device. RF Module was controlled by UHF wireless CC1020 chip which has low electrical power and low electrical voltage. Also 447.8625~447.9875 frequency, 4800Baud data rate and 12.5 kHz channel spacing was controlled by the use of SPDT switch and with Microcontroller program. Furthermore, the helical antenna was used. The starting production of 447.8625~447.9875 kHz wireless electrical power was used. As the result, it did not exceed 10dBm which is the standard of low power wireless system. Shading efficiency was measured at 25%, 50%, 75% direction with controlling the interior temperature and the intensity of illumination at the rate of 1 hour. As the result, the intensity of illumination was lowered to 82~87% at 25% direction with $0.6{\sim}1.4^{\circ}C$ lowered temperature. At 50% direction, the intensity of illumination was lowered to 60~68% with $2.3{\sim}4.1^{\circ}C$ lowered temperature. And at 75% direction, the intensity of illumination was lowered to 41~47% with $3.4{\sim}5.1^{\circ}C$ lowered temperature.

Four Channel Step Up DC-DC Converter for Capacitive SP4T RF MEMS Switch Application (정전 용량형 SP4T RF MEMS 스위치 구동용 4채널 승압 DC-DC 컨버터)

  • Jang, Yeon-Su;Kim, Hyeon-Cheol;Kim, Su-Hwan;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.2
    • /
    • pp.93-100
    • /
    • 2009
  • This paper presents a step up four channel DC-DC converter using charge pump voltage doubler structure. Our goal is to design and implement DC-DC converter for capacitive SP4T RF MEMS switch in front end module in wireless transceiver system. Charge pump structure is small and consume low power 3.3V input voltage is boosted by DC-DC Converter to $11.3{\pm}0.1V$, $12.4{\pm}0.1V$, $14.1{\pm}0.2V$ output voltage With 10MHz switching frequency. By using voltage level shifter structure, output of DC-DC converter is selected by 3.3V four channel selection signals and transferred to capacitive MEMS devices. External passive devices are not used for driving DC-DC converter. The total chip area is $2.8{\times}2.1mm^2$ including pads and the power consumption is 7.52mW, 7.82mW, 8.61mW.

Design and Implementation of Standby Power Control Module based on Low Power Active RFID (저 전력 능동형 RFID 기반 대기 전력 제어 모듈 설계 및 구현)

  • Jang, Ji-Woong;Lee, Kyung-Hoon;Kim, Young-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.491-497
    • /
    • 2015
  • In this paper a method of design and Implementation of RFID based control system for reducing standby power consumption at the power outlet is described. The system is composed of a RF controlled power outlet having relay and an active RFID tag communicating with the RF reader module controlling the relay. When the tag carried by human approaches to the RF reader the reader recognizes the tag and switch off the relay based on the RSSI level measurement. A low power packet prediction algorithm has been used to decrease the DC power consumption at both the tag and the RF reader. The result of experiment shows that successful operation of the relay control has been obtained while low power operation of the tag and the reader is achieved using above algorithm. Also setting the distance between the reader and the tag by controlling transmission power of the tag and adjusting the duty cycle of the packet waiting time when the reader is in idle state allows us to reduce DC power consumption at both the reader and the tag.

A CONSTRUCTION OF AN AUTOMATIC OBSERVATION SYSTEM FOR BRIGHT AND LONG PERIOD VARIABLE STARS (밝은 장주기 변광성관측을 위한 자동관측시스템 구축)

  • Yoon Joh-Na;Lee Chung-Uk;Cha Sang-Mok;Kim Yong-Gi
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.143-152
    • /
    • 2006
  • An automatic observation system has been constructed at Chungbuk National University for the purpose of monitoring the bright and long period variable stars effectively. We improved the control part of 40cm telescope of the LX200 and developed n observing software ObsTool II so that the telescope, CCD camera and dome can be controlled in one software. ObsTool II is a COM (Common Object Module) based software, which can be easily reprogrammed in case that a new telescope or CCD camera is installed. Because this system has an additional function in which the telescope can switch the variable, comparison, and check stars respectively as like a photoelectric observation, we can observe the variable star even if the CCD view field does not contain the comparison star with the variable star. In order to check the system stability a W UMa type variable V523 Cas and a magnetic cataclysmic variable TT Ari have been observed with the constructed system and the results have been discussed in context with the possibility of a further application of our automatical observation system.

Design and Implementation of Transformerless 40W LED Light Driver Circuit for Ships (선박용 변압기 없는 40W LED 조명 구동회로의 설계 및 구현)

  • Song, Jong-Kwan;Park, Jang-Sik;Yoon, Byung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.485-490
    • /
    • 2012
  • In this paper, driver circuit of LED lights for ships is designed and implemented to replace conventional lights with filament which have short life time due to vibration of ships. The driver of LED module is switching circuit without transformer to reduce volume and cost. As switch circuit controls input 220 VAC with PWM, LED module is reliably driven. Power factor is improved by using valley-fill PFC compensation circuit which is handled to pulse current of switching circuit. Serial-parallel LED circuit is applied to reduce change period of lights of long-term navigation ships. Array of serial-parallel can operate even if some of LEDs is damaged. It is suitable for ships that power consumption and power factor of lights including developed drive circuit have 39Watt and 0.925 respectively.

위성 Solar Array Regulator 모듈화를 위한 새로운 전원단 설계

  • Park, Sung-Woo;Park, Heei-Sung;Jang, Jin-Baek;Jang, Sung-Soo;Lee, Jong-In
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.11-19
    • /
    • 2004
  • A software-controlled unregulated bus system in which the main bus is directly connected to a battery and the duty-ratio for PWM switch is controlled by the on-board satellite software, is usually used for LEO satellites. This paper proposes a new power-stage circuit that can be available for modularization of a power regulator which is used at the software-controlled unregulated bus system satellite. And we analyze the proposed power-stage operation according to its operating modes and verify it by performing software simulation and hardware experiment using prototype. We construct a parallel-module converter which is composed of the proposed power-stage and perform experiment to verify modular characteristics of the proposed power-stage. Finally, we verify the usefulness of the proposed power-stage by comparing above results with those of a parallel-module converter made of conventional power-stage.

  • PDF

Convergence of Broadcasting and Communication in Home Network using E-PON based Home Gateway (EPON 기반 홈게이트웨이를 이용한 댁내 망에서의 방송통신 융합 서비스)

  • Park Wanki;Kim Daeyoung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.9-16
    • /
    • 2005
  • In this paper, we focus on supporting the convergence of broadcasting and communication in home network systems with E-PON based home gateway. We propose a new architecture to provide broadcasting and data services in integrated home network using overlay transport mechanism in access network and If multicast techniques of IGMP and IGMP snooping in home network. We also detail a set of mechanisms and procedures for home broadcasting service through the home gateway system. Our new scheme is composed of three parts: a) an overlay transmission model of video broadcasting signals (satellite and/or cable TV) and Internet data, b) to select a specific video broadcasting channel and to make of the selected video broadcasting stream into IP multicast packets in tuner/conversion module using multiple tuner system and c) to transfer the converted If multicast packets to L2 switch of home gateway's core module and to send them out to target port(s) by L2 multicast using IGMP snooping.

Dimming Control of the LED Luminaire Emergency Exit Sign Operation using a Hybrid Super Capacitor of DC-DC Convertor (하이브리드 슈퍼커패시터 DC-DC 컨버터를 이용한 LED 비상 유도등 동작 디밍 제어)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.220-229
    • /
    • 2017
  • In this paper, To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Boost DC-DC converter with a switch device using IRF840 and reverse recovery time Schottky diodes with excellent with constant current controller using D10SC6M and resistance can be configured to considering the Power LED Module was driven by the production. Converter's switching frequency is 50 kHz, the first Duty Rate was made to increase gradually depending on the value of the detection were, 10 % in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5% or less as the error was approximated. Finally, when input 15 V were offered, a stable output 24 V were obtained. and Dimming Control through the adjustment of brightness and current consumption were possible.

Design of Antenna for Beam Scanning for Dual-Band base station (이중대역 기지국용 빔 스캔 안테나 설계)

  • Ko Jin-Hyun;Jang Jae-Su;Ha Jae-Kwon;Park Sae-Houn
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.632-636
    • /
    • 2006
  • It is needed to use the beam scanning to control the cell coverage of the base station considering operation conditions, season, time period, radiation character and mobility of customers and vehicles for varied wireless communication service and quality improvement. This paper proposes a mobile antenna system which can obtain the characteristics of the beam scanning by controlling the directivity depending on the operation condition. Radiation block is made of 2 sub-array of $1\times3$ patched antennas for ITS of 5.8GHZ bandwidth with the gain of 13dBi, and of 2 sub-array of single patched antenna for WiBro of 2.3GHZ bandwidth with the gain of 12dBi. RF module is made of a switch, an amplifier, a PAD, a 3-Bit phase shifter, and a power divider. The system is able to control the beam tilting with electronic methode by using 3-bit phase shifter$(45^{\circ},\;90^{\circ},\;180^{\circ})$.

  • PDF

System Model-driven Conversion from PLC-based Systems to RTOS-based Systems (시스템 모델을 통한 PLC 기반 시스템의 RTOS 기반 시스템으로의 변환)

  • Kim, Je-Wung;Lim, Sung-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.3
    • /
    • pp.13-26
    • /
    • 2009
  • In this raper, We propose the alternative solution, RTOS-based system to replace the PLC 4hat has used the automation system for industrial processes. RTOS-based system is constructed the PC and RTOS as hardware and software. It overcomes the limit of PLC and guarantees the stability and reliability. Also, PC has better performance and cheaper than PLC when operating and constructing the system. For many manufactures, these benefits alone are all the reason they need to switch from PLC-based system to RTOS-based system. To use the RTOS-based System, the PLC program needs the conversion to the RTOS task. And how to transform is the most important issue. So, we propose conversion method through the system model. The system model defines the operation of each module as the task after the system divided into module. Because the system divided into modules can control, the performance and the functionality of system improve, and the system can deal with a problem easily when repairing and changing.