• Title/Summary/Keyword: surface radiation

Search Result 2,134, Processing Time 0.041 seconds

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Ecophysiological Interpretations on the Water Relations Parameters of Trees(VII) - Measurement of Water Flow by the Heat Pulse Method in a Larix leptolepis Stand - (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(VII) - Heat pulse법(法)에 의한 낙엽송임분(林分)의 수액류속(樹液流速) 계측(計測) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This is the basic study in order to know the amount of transpirational water loss in a Larix leptorepis stand by a heat pulse method. Especially this study has been measured and discussed the diurnal and seasonal trends of heat pulse velocity by changes of radiation, temperature and humidity, differences of heat pulse velocity by direction and depth in stem, differences of heat pulse velocity by dominant, codominant and suppressed trees, diurnal change of heat pulse velocity by change of leaf water potential, sap flow path way in sapwood by dye penetration and amount of daily and annual transpiration in a tree and stand. The results obtained as follows : 1. Relation between heat pulse velocity(V) and sap flow rate(SFR) was established as a equation of SFR=1.37V($r=0.96^{**}$). 2. The sap flow rate presented in the order of dominant, codominant and suppressed tree, respectively. The daily heat pulse velocity was changed by radiation, temperature and vapor pressure deficit. 3. The heat pulse velocity in individual trees did not differ in early morning and in late night, but had some differed from 12 to 16 hours when radiation was relatively high. 4. The heat pulse velocity and leaf water potential showed similar diurnal variation. 5. The seasonal variation of heat pulse velocity was highest in August, but lowest in October and similar value of heat pulse velocity in the other months. 6. The heat pulse velocity in stem by direction was highest in eastern, but lowest in southern and similar velocity in western and northern. 7. The difference of heat pulse velocity in according to depths was highest in 2.0cm depth, medium in 1.0cm depth, and lowest in 3.0cm depth from surface of stem. 8. The sap flow path way in stem showed spiral ascent turning right pattern in five sample trees, especially showed little spiral ascent turning right in lower part than 3m hight above ground, but very speedy in higher than 3m hight. 9. The amount of sap flow(SF) was presented as a equation of SF=1.37AV and especially SF in dominant tree was larger than in codominant or suppressed tree. 10. The amount of daily transpiration was 30.8ton/ha/day and its composition ratio was 83% at day and 17% at night. 11. The amount of stand transpiration per month was largest in August(1,194ton/ha/month), lowest in May (386ton/ha/month). The amount of stand transpiration per year was 3,983ton/ha/year.

  • PDF

A Statistical model to Predict soil Temperature by Combining the Yearly Oscillation Fourier Expansion and Meteorological Factors (연주기(年週期) Fourier 함수(函數)와 기상요소(氣象要素)에 의(依)한 지온예측(地溫豫測) 통계(統計) 모형(模型))

  • Jung, Yeong-Sang;Lee, Byun-Woo;Kim, Byung-Chang;Lee, Yang-Soo;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.2
    • /
    • pp.87-93
    • /
    • 1990
  • A statistical model to predict soil temperature from the ambient meteorological factors including mean, maximum and minimum air temperatures, precipitation, wind speed and snow depth combined with Fourier time series expansion was developed with the data measured at the Suwon Meteorolical Service from 1979 to 1988. The stepwise elimination technique was used for statistical analysis. For the yearly oscillation model for soil temperature with 8 terms of Fourier expansion, the mean square error was decreased with soil depth showing 2.30 for the surface temperature, and 1.34-0.42 for 5 to 500-cm soil temperatures. The $r^2$ ranged from 0.913 to 0.988. The number of lag days of air temperature by remainder analysis was 0 day for the soil surface temperature, -1 day for 5 to 30-cm soil temperature, and -2 days for 50-cm soil temperature. The number of lag days for precipitaion, snow depth and wind speed was -1 day for the 0 to 10-cm soil temperatures, and -2 to -3 days for the 30 to 50-cm soil teperatures. For the statistical soil temperature prediction model combined with the yearly oscillation terms and meteorological factors as remainder terms considering the lag days obtained above, the mean square error was 1.64 for the soil surfac temperature, and ranged 1.34-0.42 for 5 to 500cm soil temperatures. The model test with 1978 data independent to model development resulted in good agreement with $r^2$ ranged 0.976 to 0.996. The magnitudes of coeffcicients implied that the soil depth where daily meteorological variables night affect soil temperature was 30 to 50 cm. In the models, solar radiation was not included as a independent variable ; however, in a seperated analysis on relationship between the difference(${\Delta}Tmxs$) of the maximum soil temperature and the maximum air temperature and solar radiation(Rs ; $J\;m^{-2}$) under a corn canopy showed linear relationship as $${\Delta}Tmxs=0.902+1.924{\times}10^{-3}$$ Rs for leaf area index lower than 2 $${\Delta}Tmxs=0.274+8.881{\times}10^{-4}$$ Rs for leaf area index higher than 2.

  • PDF

The Effect of Shading on Pedestrians' Thermal Comfort in the E-W Street (동-서 가로에서 차양이 보행자의 열적 쾌적성에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.60-74
    • /
    • 2018
  • This study was to investigate the pedestrian's thermal environments in the North Sidewalk of E-W Street during summer heatwave. We carried out detailed measurements with four human-biometeorological stations on Dongjin Street, Jinju, Korea ($N35^{\circ}10.73{\sim}10.75^{\prime}$, $E128^{\circ}55.90{\sim}58.00^{\prime}$, elevation: 50m). Two of the stations stood under one row street tree and hedge(One-Tree), two row street tree and hedge (Two-Tree), one of the stations stood under shelter and awning(Shelter), while the other in the sun (Sunlit). The measurement spots were instrumented with microclimate monitoring stations to continuously measure microclimate, radiation from the six cardinal directions at the height of 1.1m so as to calculate the Universal Thermal Climate Index (UTCI) from 24th July to 21th August 2018. The radiant temperature of sidewalk's elements were measured by the reflective sphere and thermal camera at 29th July 2018. The analysis results of 9 day's 1 minute term human-biometeorological data absorbed by a man in standing position from 10am to 4pm, and 1 day's radiant temperature of sidewalk elements from 1:16pm to 1:35pm, showed the following. The shading of street tree and shelter were mitigated heat stress by the lowered UTCI at mid and late summer's daytime, One-Tree and Two-Tree lowered respectively 0.4~0.5 level, 0.5~0.8 level of the heat stress, Shelter lowered respectively 0.3~1.0 level of the heat stress compared with those in the Sunlit. But the thermal environments in the One-Tree, Two-Tree and Shelter during the heat wave supposed to user "very strong heat stress" while those in the Sunlit supposed to user "very strong heat stres" and "exterme heat stress". The main heat load temperature compared with body temperature ($37^{\circ}C$) were respectively $7.4^{\circ}C{\sim}21.4^{\circ}C$ (pavement), $14.7^{\circ}C{\sim}15.8^{\circ}C$ (road), $12.7^{\circ}C$ (shelter canopy), $7.0^{\circ}C$ (street funiture), $3.5^{\circ}C{\sim}6.4^{\circ}C$ (building facade). The main heat load percentage were respectively 34.9%~81.0% (pavement), 9.6%~25.2% (road), 24.8% (shelter canopy), 14.1%~15.4% (building facade), 5.7% (street facility). Reducing the radiant temperature of the pavement, road, building surfaces by shading is the most effective means to achieve outdoor thermal comfort for pedestrians in sidewalk. Therefore, increasing the projected canopy area and LAI of street tree through the minimal training and pruning, building dense roadside hedge are essential for pedestrians thermal comfort. In addition, thermal liner, high reflective materials, greening etc. should be introduced for reducing the surface temperature of shelter and awning canopy. Also, retro-reflective materials of building facade should be introduced for the control of reflective sun radiation. More aggressively pavement watering should be introduced for reducing the surface temperature of sidewalk's pavement.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.

A Short Composting Method by the Single Phase Composter for the Production of Oyster Mushroom (느타리버섯 배지 제조기를 이용한 배지의 제조 연구)

  • Lee, Ho-Yong;Shin, Chang-Yup;Lee, Young-Keun;Chang, Hwa-Hyoung;Min, Bong-Hee
    • The Korean Journal of Mycology
    • /
    • v.27 no.1 s.88
    • /
    • pp.10-14
    • /
    • 1999
  • A single phase composter was constructed by modifying the conventional mixer of sawdust for the cultivation of oyster mushroom Pleurotus ostreatus. The machine was designed on the basis of 3-phase-1 system which was controlled in prewetting, pasteurization and fermentation processes. In composting 200 kg of straw and cotton waste in the machine, it took 20 minutes in prewetting step and also to hours at $65^{\circ}C$ in pasteurization process. Postfermentation by aerothermophiles was completed by treating the compost at $45^{\circ}C-50^{\circ}C$ for 48 hours which was shorten 24 hours from the conventional method. In the postfermentation at high temperature, forced aeration and/or vigorous mixing process(es) played a great role in the improvement of spawn quality. The growth of mycelium of oyster mushroom was excellent in the culture combinated with 3 parts of surface inoculation and 7 parts of mechanical mixing.

  • PDF

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

Variations in Soil-to-Red Pepper Transfer Factors of Radionuclides with Time of Their Application and Fruit Harvest (고추 재배시 방사성 핵종 처리 및 열매수확 시기에 따른 토양-작물체간 전이계수의 변이)

  • Choi, Yong-Ho;Lee, Won-Yun;Lim, Kwang-Muk;Park, Doo-Won;Lee, Myung-Ho;Lee, Chang-Woo;Lee, Hyun-Duk;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.171-181
    • /
    • 1997
  • A mixed solution of $^{54}Mn$, $^{60}Co$, $^{85}Sr$ and $^{137}Cs$ was applied to the soil of culture boxes in a greenhouse 2 days before transplanting red pepper and at 3 different times during its growth for investigating transfer factors ($m^2/kg-dry$) for its green and red fruits. Transfer factors varied with radionuclide, application time and harvest time by factors of about $20{\sim}100$. They decreased mostly in the order of $^{85}Sr>^{54}Min>^{60}Co>^{137}Cs$ while $^{54}Mn$ and $^{60}Co$ was higher than $^{85}Sr$ when time lapse between application and harvest was short. Transfer factors of $^{85}Sr$ and $^{137}Cs$ at the last application were lower than those at the previous one by factors of $3{\sim}20$ depending on harvest time. Variations in $^{54}Mn$ and $^{60}Co$ transfer factors with application time after transplanting were comparatively low. Transfer factors of $^{54}Mn$, $^{60}Co$ and $^{85}Sr$ mixed with topsoil before transplanting were up to $3{\sim}9$ times higher than those for the application onto soil surface 2 days after transplanting while there was no difference in $^{137}Cs$. The present results can be referred to in estimating root-uptake concentrations of the radionuclides in red pepper fruit and taking proper measures for its harvest and consumption at the event of an accidental release during the growing season of red pepper.

  • PDF

Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ Deposited at Different Times during the Growing Season of Rice (벼 재배 기간중 침적시기에 따른 Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$의 뿌리흡수)

  • Choi, Yong-Ho;Jo, Jae-Seong;Lee, Chang-Woo;Hong, Kwang-Hee;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.255-263
    • /
    • 1995
  • Root uptakes of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ by rice were studied through a greenhouse experiment in which the upper 20 cm of the culture box was filled with an acidic loamy-sandy soil and a mixed solution of the radionuclides was applied to the surface water on the soil 2 days before, and 5 different times after, transplanting. Percent uptakes of the radionuclides to rice tops varied $3.4{\sim}13.7%,\;0.03{\sim}0.1%,\;0.6{\sim}1.5%,\;0.02{\sim}0.15%$, respectively, with application time. Among radionuclides, soil-to-plant transfer factors decreased, on the whole, in the order of $^{54}Mn>^{85}Sr>^{60}Co{\geq}^{137}Cs$, and among plant parts, in the order of straw > chaff > hulled seed. Transfer factors $(m^2/kg-dry)$ in hulled seed were, depending on application time, $1.2{\times}10^3{\sim}5.0{{\times}10^3\;for\;^{54}Mn,\;1.6{\times}10^5{\sim}2.6{\times}10^4\;for\;^{60}Co,\;1.1{\times}10^4{\sim}7.6{\times}10^4\;for\;^{85}Sr\;and\;5.2{\times}10^5{\sim}7.0{\times}10^4\;for\;^{137}Cs$. The highest factors of all the radionuclides in straw came from the application at 67 days after transplanting while those of $^{54}Mn,\;^{60}Co\;and\;^{85}Sr$ in hulled seed appeared at later applications. The data from this studv can be referred to in assessing the radiological impact of an accidental contamination during the rice growth.

  • PDF

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF