• Title/Summary/Keyword: surface and interface

Search Result 2,782, Processing Time 0.036 seconds

Blob and Wave Formation at the Free Edge of an Initially Stationary fluid Sheet (액체 필름 끝단에서의 유동특성에 관한 수치연구)

  • Song Museok;Ahn Jail
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.307-310
    • /
    • 2002
  • A two-dimensional numerical method for inviscid two-fluid flows with evolution of density interface is developed, and an initially stationary two-dimensional fluid sheet surrounded by another fluid is studied. The Interface between two fluids is modeled as a vertex sheet, and the flow field u÷th the evolution of interface is solved by using vortex-in-cell/front-tracking method. The edge of the sheet Is pulled back into the sheet due to surface tension and a blob is formed at the edge. This blob and fluid sheet are connected by a thin neck. In the inviscid limit, such process of the blob and neck formation is examined in detail and their kinematic characteristics are summarized with dimensionless parameters. The edge recedes at $V=1.06({\sigma}/{\rho}h)^{0.5}$ and the capillary wave Propagating into the fluid sheet must be considered for bettor understanding of the edge receding.

  • PDF

Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

A Study on the Solid State Diffusion Bonding of Ti-6Al-4V Alloy (Ti-6Al-4V합금의 고상 확산접합에 관한 연구)

  • 강호정;강춘식
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.32-40
    • /
    • 1997
  • Solid state diffusion bonding is the joining process performed by creep and diffusion, which is accelerated by heating below melting temperature and proper pressing, in vacuum or shielding gas atmosphere. By this process we can obtain sufficient joint which can't be expected from the fusion welding. For Ti-6Al-4V alloy, the optimum solid state diffusion bonding condition and mechanical properties of the joint were found, and micro void morphology at bond interface was observed by SEM. The results of tensile test showed sufficient joint, whose mechanical properties are similar to that of base metal. 850$^{\circ}$C, 3MPa is considered as the optimum bonding condition. Void morphology at interface is long and flat at the initial stage. As the percentage of bonded area increases, however, small and round voids are found. Variation of void shape can be explained as follows. As for the void shrinkage mechanism, at the initial stage, power law creep is the dominant, but diffusion mechanism is dominant when the percentage of bonded area is increased.

  • PDF

The Substrate Effects on Kinetics and Mechanism of Solid-Phase Crystallization of Amorphous Silicon Thin Films

  • Song, Yoon-Ho;Kang, Seung-Youl;Cho, Kyoung-Ik;Yoo, Hyung-Joun
    • ETRI Journal
    • /
    • v.19 no.1
    • /
    • pp.26-35
    • /
    • 1997
  • The substrate effects on solid-phase crystallization of amorphous silicon (a-Si) films deposited by low-pressure chemical vapor deposition (LPCVD) using $Si_2H_6$ gas have been extensively investigated. The a-Si films were prepared on various substrates, such as thermally oxidized Si wafer ($SiO_2$/Si), quartz and LPCVD-oxide, and annealed at 600$^{\circ}C$ in an $N_2$ ambient for crystallization. The crystallization behavior was found to be strongly dependent on the substrate even though all the silicon films were deposited in amorphous phase. It was first observed that crystallization in a-Si films deposited on the $SiO_2$/Si starts from the interface between the a-Si and the substrate, so called interface-interface-induced crystallization, while random nucleation process dominates on the other substrates. The different kinetics and mechanism of solid-phase crystallization is attributed to the structural disorderness of a-Si films, which is strongly affected by the surface roughness of the substrates.

  • PDF

Modeling the Threshold Voltage of SiC MOSFETs for High Temperature Applications (고온 응용을 위한 SiC MOSFET 문턱전압 모델)

  • 이원선;오충완;최재승;신동현;이형규;박근형;김영석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.559-563
    • /
    • 2002
  • A threshold voltage model of SiC N-channel MOSFETs for high-temperature and hard radiation environments has been developed and verified by comparing with experimental results. The proposed model includes the difference in the work functions, the surface potential, depletion charges and SiC/$SiO_2$acceptor-like interface state charges as a function of temperature. Simulations of the model shoved that interface slates were the most dominant factor for the threshold voltage decrease as the temperature increase. To verify the model, SiC N-chnnel MOSFETS were fabricated and threshold voltages as a function of temperature were measured and compared wish model simulations. From these comparisons, extracted density of interface slates was $4{\times}10^{12}\textrm{cm}^{-2}eV^{-1}$.

A Study on the Adhesive Improvement of Glass cloth/Epoxy Composite Insulating Materials(2) - For Improvement of Wettability on the Interface - (유리섬유/에폭시 복합절연재료의 계면 접착력 개선에 관한 연구(2) - 절연특성 향상에 관하여 -)

  • Kim, Soon-Tae;Hwang, Yeong-Han;Park, Hong-Tae;Eom, Moo-Soo;Lee, Kyu-Chul;Lee, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1061-1065
    • /
    • 1995
  • To improve dielectric and mechanical properties of insulating composite by plasma surface treatment, new plasma surface treatment process is designed with concentric and hemi-circle electrodes system, the plasma, which is generated between anode and cathode, is induced to the upper side of the electrode system and treats the surface of the insulators. The optimal surface treatment condition is that pressure : 0.5[torr], flux density 100[gauss], discharge current : 500[mA] and treatment time : 3 minutes. The composite filled with glass cloth surface-treated by plasma shows the improvement in electric and mechanical properties, comparing non- and coupling agent-treated samples.

  • PDF

Investigation of Adhesion Mechanism at the Metal-Organic Interface Modified by Plasma - Part I

  • Sun, Yong-Bin
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.123-126
    • /
    • 2002
  • For the mold die sticking mechanism, the major explanation is that EMC filler of silica wears die surface roughened, which results in increase of adhesion strength. As big differences in experimental results from semiconductor manufacturers are dependent on EMC models, however, chemisorptions or acid-base interaction is apt to be also functioning as major mechanisms. In this investigation, the plasma source ion implantation (PSII) using $O_2$, $N_2$, and $CF_4$ modifies sample surface to form a new dense layer and improve surface hardness, and change metal surface condition from hydrophilic to hydrophobic and vice versa. Through surface energy quantification by measuring contact angle and surface ion coupling state analysis by Auger, major governing mechanism for sticking issue was figured out to be a complex of mechanical and chemical factors.

  • PDF

Basic Analysis of Bubble Behavior in the Viscous Flow Domain with the Free Interface (자유표면을 가지는 점성 유동장내의 기포거동에 관한 기초해석)

  • I.R. Park;H.H. Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-27
    • /
    • 2002
  • A level-set method is used for analyzing the behaviors of gas bubbles in two fluids incompressible viscous flow domain. The governing equations are solved by using a finite volume method. The numerical results are verified by comparing with the experimental and other computational results. Computations for the deformations and motions of one or multi-bubbles in the flow domain with the initial undisturbed free interface are conducted. It can be seen that numerical results for different surface tension and density ratio arise very different behaviors of bubbles. When bubbles rise near the free interface, the free interface gives some great influence on the behaviors of bubbles. The present results computed by a level-set method give useful information about the properties of bubble motions and deformations.

A Study on the Ferromagnetic Resonance of FeNb Thin Films (FeNb 박막의 강자성 공명 연구)

  • Lim, Woo-Young;Baek, Jong-Sung;Lee, Soo-Hyung
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.120-126
    • /
    • 2004
  • In order to understand the temperature dependence of magnetic properties of $F_{84}Nb_{16}$(wt.%) thin films, ferromagnetic resonance experiments have been carried out. The ferromagnetic resonance spectra for all temperatures consist of several volume modes and one (or two) surface modes. It is suggested that both surface of the film have a perpendicular hard axis to the film plane (negative surface magnetic anisotropy). Saturation magnetization coincides with the Block's T$\^$2/3/ and spectroscopic splitting factor is almost constant in the temperature range from 113 K to 293 K. The surface magnetic anisotropy constant K$\_$s2/ of the film-substrate interface increased with decreasing temperature in the temperature range from 233 K to 293 K. The surface magnetic anisotropy constant K$\_$s1/ of the air-substrate interface decreased from -0.322 erg/$\textrm{cm}^2$ to -0.394 erg/$\textrm{cm}^2$ as the temperature decreased to 253 K and was almost constant below 233 K.233 K.

EFFECTS OF DENTIN SURFACE WETNESS OR DESICCATION AFTER ACID ETCHING ON DENTIN BONDING (산부식후 상아질 표면의 습윤 또는 건조가 상아질 결합에 미치는 영향)

  • Yang, Won-Kyung;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.243-253
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate dentin bonding by two different dentin bonding systems(DBS) using acetone based primer or adhesive [All Bond 2(AB2), One Step(OS)] when they were applied by wet or dry bonding technique. Morphology of resin-dentin interface and hybrid layer thickness(HLT) were investigated using Confocal Laser Scanning Microscope(CLSM) and compared to shear bond strength(SBS). 72 extracted sound human molars were randomly divided into 4 groups of 18 teeth each - Group 1.(AW); AB2 by wet bonding. Group 2(AD); AB2 by dry bonding. Group 3.(OW); OS by wet bonding, Group 4.(OD); OS by dry bonding. In 6 teeth of each group, notch-shaped class V cavities(depth 2mm) were prepared on buccal and lingual surface at the cementoenamel juction(12 cavities per group). To obtain color contrast in CLSM observation, bonding resins of each DBS were mixed with rhodamine B and primer of AB2 was mixed with sodium fluorescein. Prepared teeth of each group were treated with AB2, OS, respectively according to the manufacturer's instructions except for dentin surface moisture treatment after acid etching. In group 1 and 3, after acid etching, excess water was removed with wet tissue(Kimwipes), leaving consistently shiny, visibly hydrated dentin surface. In group 2 and 4, dentin surface was dried for 10 seconds at 1 inch distance. The treated teeth were then packed with composite resin(${\AE}$litefil) and light-cured. 12 microscopic samples($60{\sim}80{\mu}m$ thickness) of each group were obtained after longitudinal section and grinding(Exakt cutting and grinding system). Morphological investigation of resin-dentin interface and HLT measurement using CLSM were done. For measurement of SBS, remaining 12 teeth of each group were flattened occlusally to remove all enamel and grinded to 500 grit SiC(Pedemet Specimen Preparation Equipment). After applying DBS on the exposed dentin surface, composite resin was applied in the shape of cylinder, which has 5mm diameter, 1.5mm thickness, and light cured. SBS was measured using Instron with a crosshead speed of 0.5mm/min. It was concluded as follows, 1. HLT of AW(mean: $2.59{\mu}m$) was thicker than any other group, and followed by AD, OW, OD in descending order(mean; 2.37, 2.28, $1.92{\mu}m$). Only OD had statistically significant differences(p<0.05) to AW and AD. 2. There were intimate contact of resin and dentin at the interface in wet bonding groups, but gaps or irregular interfaces were observed in dry bonding groups. 3. The length, diameter, density of resin tags were various even in the same group without significant differences between groups and lots of adhesive lateral branches were observed. 4. There were no statistically significant difference of SBS between AB2 and OS, but SBS of wet bonding groups were significantly higher(p<0.05) than dry bonding groups. 5. There were no consistent relationships between HLT and SBS.

  • PDF