• 제목/요약/키워드: surface and interface

검색결과 2,772건 처리시간 0.029초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

정전류 펄스법을 이용한 콘크리트 내 보강철근의 부식 연구 (The Use of Galvanostatic Pulse Transient Techniques for Assessing of Corrosion Rate of Reinforcing steel in Concrete)

  • 소형석
    • 콘크리트학회논문집
    • /
    • 제19권6호
    • /
    • pp.785-793
    • /
    • 2007
  • 본 연구는 정전류 펄스법을 이용하여 콘크리트 내 보강철근의 부식률을 정량적으로 평가한 실험 결과를 나타낸 것이다. 콘크리트와 보강철근의 부식 경계면에서 미소전류의 인가에 의해 변화되는 부식전위 $({\Delta}E)$를 분석함으로써 보강철근의 분극저항 $R_{ct}$는 저항/커패시턴스 (resistance/capacitance)모델에 기초하여 개별 성분으로 분리되었다. 분리된 각 성분에는 부식 과정과 관련된 저항뿐 아니라 콘크리트 내 이온의 확산저항 등과 같은 부식에 관계없는 저항 성분들도 포함되어 있었다. 참조 전극과 보강철근의 측면 이격 거리에 따른 일련의 실험 결과는 부식 과정에 관계없는 저항 성분들로부터 부식에 관련된 저항 성분을 명확히 구별할 수 있음을 잘 보여주고 있다. 만일 보강철근의 부식률이 부식에 관계없는 저항 성분들까지 포함된 분극저항에 의해 평가된다면, 보강철근의 부식률은 실제의 부식 상태보다 최대 2.3배까지 과소평가될 수 있는 것으로 조사되었다. 측정 시간이 부식률 평가에 미치는 영향은 부식 철근의 경우 크지 않았지만, 측정 시간이 길어짐에 따라 부식에 관계없는 저항성분이 포함될 수 있음을 보였고, 비교적 늦은 시상수 (time constant)를 갖는 부동태 철근의 경우 측정 시간에 큰 영향을 받는 것으로 조사되었다.

The intrinsic instabilities of fluid flow occured in the melt of Czochralski crystal growth system

  • Yi, Kyung-Woo;Koichi Kakimoto;Minoru Eguchi;Taketoshi Hibiya
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.179-200
    • /
    • 1996
  • The intrinsic instabilities of fluid flow occurred in the melt of the Czochralski crystal growth system Czochralski method, asymmetric flow patterns and temperature profiles in the melt have been studied by many researchers. The idea that the non-symmetric structure of the growing equipment is responsible for the asymmetric profiles is usually accepted at the first time. However further researches revealed that some intrinsic instabilities not related to the non-symmetric equipment structure in the melt could also appear. Ristorcelli had pointed out that there are many possible causes of instabilities in the melt. The instabilities appears because of the coupling effects of fluid flow and temperature profiles in the melt. Among the instabilities, the B nard type instabilities with no or low crucible rotation rates are analyzed by the visualizing experiments using X-ray radiography and the 3-D numerical simulation in this study. The velocity profiles in the Silicon melt at different crucible rotation rates were measured using X-ray radiography method using tungsten tracers in the melt. The results showed that there exits two types of fluid flow mode. One is axisymmetric flow, the other is asymmetric flow. In the axisymmetric flow, the trajectory of the tracers show torus pattern. However, more exact measurement of the axisymmetrc case shows that this flow field has small non-axisymmetric components of the velocity. When fluid flow is asymmetric, the tracers show random motion from the fixed view point. On the other hand, when the observer rotates to the same velocity of the crucible, the trajectory of the tracer show a rotating motion, the center of the motion is not same the center of the melt. The temperature of a point in the melt were measured using thermocouples with different rotating rates. Measured temperatures oscillated. Such kind of oscillations are also measured by the other researchers. The behavior of temperature oscillations were quite different between at low rotations and at high rotations. Above experimental results means that the fluid flow and temperature profiles in the melt is not symmetric, and then the mode of the asymmetric is changed when rotation rates are changed. To compare with these experimental results, the fluid flow and temperature profiles at no rotation and 8 rpm of crucible rotation rates on the same size of crucible is calculated using a 3-dimensional numerical simulation. A finite different method is adopted for this simulation. 50×30×30 grids are used. The numerical simulation also showed that the velocity and flow profiles are changed when rotation rates change. Futhermore, the flow patterns and temperature profiles of both cases are not axisymmetric even though axisymmetric boundary conditions are used. Several cells appear at no rotation. The cells are formed by the unstable vertical temperature profiles (upper region is colder than lower part) beneath the free surface of the melt. When the temperature profile is combined with density difference (Rayleigh-B nard instability) or surface tension difference (Marangoni-B nard instability) on temperature, cell structures are naturally formed. Both sources of instabilities are coupled to the cell structures in the melt of the Czochralski process. With high rotation rates, the shape of the fluid field is changed to another type of asymmetric profile. Because of the velocity profile, isothermal lines on the plane vertical to the centerline change to elliptic. When the velocity profiles are plotted at the rotating view point, two vortices appear at the both sides of centerline. These vortices seem to be the main reason of the tracer behavior shown in the asymmetric velocity experiment. This profile is quite similar to the profiles created by the baroclinic instability on the rotating annulus. The temperature profiles obtained from the numerical calculations and Fourier transforms of it are quite similar to the results of the experiment. bove esults intend that at least two types of intrinsic instabilities can occur in the melt of Czochralski growing systems. Because the instabilities cause temperature fluctuations in the melt and near the crystal-melt interface, some defects may be generated by them. When the crucible size becomes large, the intensity of the instabilities should increase. Therefore, to produce large single crystals with good quality, the behavior of the intrinsic instabilities in the melt as well as the effects of the instabilities on the defects in the ingot should be studied. As one of the cause of the defects in the large diameter Silicon single crystal grown by the

  • PDF

열순환이 상아질 접착제의 결합 내구성에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS)

  • 문영훈;김종률;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.222-235
    • /
    • 2007
  • 이 논문의 목적은 열순환이 4종 상아질 접착 시스템의 결합 내구성에 미치는 영향을 측정한 것이다. 제3대구치의 상아질층을 노출시킨 후, 무작위로 8개군으로 나눈다: 3단계 산부식 시스템 (Scotchbond Multi-Purpose Plus; SM, All Bond-2 ; AB), 2 단계 산부식 시스템 (Single Bond; SB, One Step plus, OS), 2단계 자가부식 시스템 (Clearfil SE Bond; SE, AdheSE; AD), 1 단계 자가부식 시스템 (Promp L-Pop ; PL, Xeno III; XE). 8개 군에 각 상아질 접착제를 제조사의 지시에 따라 도포하고 복합레진 (Z250)을 적층한 후, 광조사한다. $37^{\circ}C$ 증류수에서 24시간 보관한 후, 각 군마다 정해진 프로그램으로 0, 1000, 2000회 열순환한 후, 저속 diamond saw로 $1\times1mm$ 막대형 시편을 제작한다. Universal testing machine (EZ-test; Shimadzu, Japan)으로 미세인장 결합강도를 측정하였고, 유의수준 0.05 level에서 ANOVA / Duncan's test로 통계분석 하였다. 상아질측 파단면과 접착계면에 대한 주사전자현미경 관찰을 시행하였다. 이 연구의 결과는 다음과 같다; 1. 3단계 상아질 접착제의 결합강도는 열순환 전후에 통계학적으로 유의한 변화를 나타내지 않았다. 2단계 산부식형 상아질 접착제의 결합강도는 열순환 처리에 의하여 유의하게 감소되었다. 2. 2단계 자가부식형 접착제 (SE)의 결합강도가 가장 높았고, 1단계 자가부식 접착제 (PL, XE)는 실험군 중 가장 낮은 결합강도를 보였다. 3. 모든 접착제는 주로 접착성 파괴가 발생하였고, 열순환에 의하여 산부식형 접착제는 접착성 파괴가, 1단계 자가부식형 접착제에서는 혼합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.

비교원성 단백질이 상아질 접착제의 결합강도와 교원질의 형태에 미치는 영향 (THE EFFECT OF THE REMOVAL OF CHONDROITIN SULFATE ON BOND STRENGTH OF DENTIN ADHESIVES AND COLLAGEN ARCHITECTURE)

  • 김종률;박상진;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제35권3호
    • /
    • pp.211-221
    • /
    • 2010
  • 본 연구는 상아질의 비교원성 단백질을 chondroitinase ABC (C-ABC)를 이용하여 제거함으로써 비교원성 단백질의 제거가 상아질 접착제의 미세인장결합강도와 교원질망의 형태에 미치는 영향을 상아질의 다양한 습윤상태에 따라 평가하고자 시행하였다. 비교원성 단백질의 상아질접착제의 미세인장강도에 대한 영향을 평가하기 위해 제 3대구치의 상아질을 노출시키고, 두 군으로 나누고 한 군은 C-ABC, 다른 군은 증류수를 $37^{\circ}C$에서 48시간 동안 적용한 후, 상아질의 습윤상태(wet, dry 및 re-wet)와 상아질 접착제(Single Bond 2, One Step Plus)를 다르게 이용하여 복합레진을 수복하였다. 24시간 후 가로 1 mm, 세로 1mm의 시편을 제작하고 미세인장강도를 측정하였다. 상아질 교원질의 형태변화를 관찰하기 위하여 상아질 시편에 산부식을 시행하고 C-ABC 적용 후, 시편을 제작하였고 미세인장강도 측정후 파괴된 접착면의 파괴양상과 각 접착제의 접착계면 관찰을 위하여 FE-SEM 관찰하였다. C-ABC 처리여부와 관계없이 습윤한 상아질면에 접착한 군은 모든 접착제에서 통계학적으로 유의성있는 미세인장결합강도의 차이를 나타나지 않았다(p > 0.05). C-ABC를 적용하였을 경우, Single Bond 2에서는 재수화한 상아질면에 접착한 군이 습윤한 상아질면에 접착한 군에 비해 미세인장결합강도가 감소하였다(p < 0.05). FE-SEM 관찰결과, C-ABC를 적용후에는 접착성 파괴가 주로 일어났으며, 교원질 섬유간 거리가 증가하였으며 부분적으로 교원질 섬유들간에 응집된 양상이 관찰되었다.

치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향 (INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL)

  • 이정태;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.166-179
    • /
    • 1999
  • 외과적 근관치료에서 근단부의 폐쇄성은 성공에 필수적이다. 그리고 외과적 근관치료시 근단부 역충전와동은 습기나 혈액에 의해 오염되기 쉬우며 와동을 이상적으로 건조하기가 항상 용이하지는 않다. 본 연구의 목적은 미세 치근단 수술법에서 치근단 역충전와동의 건조 방법이 폐쇄성에 미치는 영향을 연구하고자 함이다. 치근단 폐쇄성은 근단 누출 및 충전물-와벽 적합성으로 평가하였다. 치근단 역충전와동 건조방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 대구치 구개측치근 125개를 와동건조 방법 및 혈액오염에 따라 4개의 군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 초음파 스테인레스 스틸 기구를 이용하여 깊이 3mm의 역충전 와동을 형성하고 IRM, Super EBA 또는 복합레진으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 흡광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였다. 역충전 와동 건조방법에 따른 충전물-와벽 적합성을 평가하기 위해서는 상악 제 1대구치의 구개측 치근 12개를 상기와 같이 4개 군으로 분류하여 근관충전, 역충전와동 형성, 와동 건조 및 역충전을 실험하였으며, 다음과 같은 결과를 얻었다. 1. 압축공기나 paper point로 와동을 건조한 군이, 역충전 와동을 IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 충전한 경우 공히, cottton pellet 만으로 와동을 건조한 군에 비해 적은 치큰단 누출을 나타내었는데 이는 Super EBA 시멘트 충전군에서만 유의한 차이를 나타내었다(p<0.05). 그러나 충전재료에 관계없이 paper point로 와동을 건조한 군과 압축공기로 건조한 군 사이에는 유의한 누출의 차이가 나타나지 않았다. 2. 압축공기로 와동을 건조한 경우에는, 복합레진으로 충전한 군이 IRM이나 Super EBA로 충전한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.05). 3. 와동을 혈액으로 오염시킨 경우에는, 역충전 와동을 IRM, Super EBA 및 복합레진으로 충전한 군 공히, 압축공기로 와동내부를 건조한 경우에 비해 유의하게 많은 치큰단 누출을 나타내었다(p<0.05). 4. IRM 간이충전재나 Super EBA 시멘트로 역충전와동을 충전한 경우, 와동측벽의 외측 1/2이 내측 1/2에 비해 넓은 충전물-치질 사이 틈을 나타내었다. 5. IRM 간이충전재, Super EBA 시멘트 및 복합레진으로 역충전와동을 충전한 경우 공히, 와동이 혈액에 의해 오염되었거나 와동을 cotton pellet으로만 건조한 경우가 paper point나 압축공기로 와동을 건조한 경우에 비해 와동기저부에 큰 틈을 나타내는 양상을 보였다.

  • PDF

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도 (The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching)

  • 김유리;김지환;심준성;김광만;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.148-156
    • /
    • 2008
  • 자가부식 접착제는 사용하기 쉽고, 술식 민감성이 적은 장점이 있으나 특히 산도가 약한 자가부식 접착제의 법랑질에 대한 결합력은 논란이 되고 있다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond (Kuraray, Okayama, Japan)의 연마 법랑질에 대한 미세인장 결합강도를 측정하여 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) 및 1단계 자가부식 접착제인 iBond (Heraeus Kulzer Gmbh, Hanau, Germany)의 결합강도와 비교하고자 하였고, 2단계 자가부식 접착제에 산부식 전처리를 시행하는 것이 법랑질에 대한 결합강도를 높일 수 있는지 알아 보고자 하였다. 실험군은 2단계 자가부식 접착제인 Clearfil SE Bond만 사용한 비산부식 군과 35% 인산 (Scotchbond Etchant, 3M ESPE)으로 산부식 후 Clearfil SE Bond를 사용한 산부식 군, 그리고 1단계 자가부식 접착제인 iBond를 사용한 군으로 나누었다. 대조군은 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose를 사용한 군으로 정하였다. Bovine 전치의 순면을 십자가형으로 4등분하여 각 군으로 무작위로 배분하였다. 각 치아의 순면을 800-grit 실리콘 카바이드 지로 연마한 후 삭제된 법랑질면에 제조사의 설명서에 따라 각 군의 접착제를 적용하고 Light-Core (Bisco)로 적층 충전하였다. 시편은 $37i{\acute{E}}$, 증류수에 일주일 동안 보관한 후 low speed precicion diamond saw (TOPMENT Metsaw-LS, R&B, Daejeon, Korea)를 이용하여 약 $0.8{\times}0.8mm$ 단면이 되도록 시편을 절단하여 미세시편을 제작하였다. 일주일마다 증류수를 교환하면서 한 달, 세 달 동안 $37i{\acute{E}}$, 증류수에 미세시 편을 보관한 후 각각의 미세인장결합강도를 측정하였다. 미세인장결합강도 (MPa)는 파절 시에 가해진 힘 (N)을 접착면적 ($mm^2$)으로 나누어 계산하였다. 접착계면에서의 파절 양상은 실물현미경 (Microscope-B nocular, Nikon)을 이용하여 분류하였다. 미세인장결합강도에 대한 통계분석은 one-way ANOVA를 이용하여 유의수준 5%에서 검정하였고, 사후감정은 Least Significant Difference 방법을 이용하였다. 중합 후 1개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 모든 접착제 간에 유의한 차이가 없었다. 3개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 iBond 와 Clearfil SE Bond 비산부식 군과 Scotchbond Multi- Purpose 간에는 각각 유의한 차이가 없었다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond의 연마 법랑질에 대한 미세인장결합강도가 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose 와 비교하여 유의한 차이가 없었으며 (P>0.05), 3개월 후의 결과에서 Clearfil SE Bond 비산부식 군의 미세인장결합강도가 Clearfil SE Bond 산부식 군보다 유의하게 낮았다 (P<0.05). 즉 35% 인산으로 산부식 전처리를 시행한결과 Clearfil SE Bond 의 법랑질에 대한 결합강도가 증가하였다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

지질매체내에서의 $^{241}Am,\;^{152}Eu,\;^{160}Tb,\;^{60}Co$의 흡착특성비교: 지표지질내에서의 Am의 거동특성을 위한 최적 유사체로서의 Eu (Sorption Behavior of $^{241}Am,\;^{152}Eu,\;^{160}Tb\;and\;^{60}Co$ in the Geological Materials: Eu as an Optimum Analogue for Fate and Transport of Am Behavior in Subsurface Environment)

  • 이승구;이길용;조수영;윤윤열;김용제
    • 자원환경지질
    • /
    • 제40권4호
    • /
    • pp.361-374
    • /
    • 2007
  • 희토류원소는 지각의 진화, 분화작용 등을 포함한 여러 가지 지질학적 역사를 이해하는 매우 유용한 도구로서 활용되어 왔다. 뿐만 아니라, 이 희토류원소는 방사성폐기물의 처분과 관련된 물-암석반응연구에 있어서 액티나이드 원소의 유사체로서 사용되어져 왔다. 본 논문에서는 희토류원소인 Eu와 액티나이드 원소인 Am의 유사한 물리적/화학적 특성을 토대로 지질매체의 종류에 관계없이 희토류원소와 액티나이드 원소의 거동이 매우 유사하다는 가설을 설정하고 이를 검증하기 위한 회분식(batch experiment) 실험을 수행하였다. 회분식 실험에는 4종류의 암석(화강암, 화강암질 편마암, 앰피볼라이트, 응회암)을 지질매체로 선택하였고, 고준위 방사성 핵종으로는 액티나이드계열인 $^{241}Am$, 희토류원소 계열인 $^{152}Eu,\;^{160}Tb$을 선택하였고, 중저준위 핵종으로는 $^{60}Co$를 사용하였다. 특히 $^{160}Tb$$^{60}Co$$^{241}Am-^{152}Eu$의 흡착능과 다른 방사성핵종의 흡착능을 비교하는데 사용되었다. 핵종과 혼합한 흡착실험용 용액의 pH는 5.5전후로 조절하였다. 실험결과, $^{241}Am,\;^{152}Eu,\;^{160}Tb$의 흡착 특성은 암상의 변화에 관계없이 매우 유사하게 나타났지만, $^{60}Co$는 다르게 나타났다. 이는 $^{60}Co$의 흡착특성은 암상의 종류에 따라 큰 차이가 있음을 지시해주는 것이다. 이와 같은 실험결과는 1) 희토류원소 중 Eu이 지표지질하에서의 Am의 거동을 추적하고 예측하기 위한 최적 유사체이고, 2) 비록 암석가루의 비표면적 혹은 양이온교환능과 같은 물리적/화학적 특성에 의한 영향을 배제할 수는 없지만, $SiO_2,\;TiO_2,\;P_2O_5$같은 화학조성 및 Eu의 이상과 같은 희토류원소의 분포도의 차이가 지표지질하에서의 방사성 핵종의 흡착거동에 중요한 역할을 하고 있음을 지시해주는 것이다.