Ventilation effectiveness measurements utilizing a tracer gas in an under floor air-conditioning space (추적가스를 이용한 바닥취출 공조공간내의 환기효율 측정실험)

  • 한화택;서세영;김명호;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.610-618
    • /
    • 1998
  • In this study, a tracer gas technique was used to measure ventilation effectiveness in a thermal environmental chamber simulating an under-floor air conditioning system. A tracer gas of $SF_6$ was injected in a supply duct using step-up and step-down methods. Local mean ages and room mean ages were calculated from the measured concentrations under isothermal and cooling conditions with and without diffusers. Ventilation effectiveness is found to be higher in cooling ventilation operations than in isothermal operations. Results also show that ventilation effectiveness is not significantly affected by a diffuser.

  • PDF

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

A Study on simulation analysis of the microbe transport of air-born virus in hospital for microbiological safety (미생물 안전을 위한 병원건물의 환기설계에 따른 공기 감염균 확산에 관한 시뮬레이션 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.115-123
    • /
    • 2017
  • Recently there is a growing interest in the airborne spread of virus. In particular, there is growing interest in secondary infection through the air in the hospital. The distribution of air-born virus depends on ventilation system installed in a hospital. In this study, simulations were carried out to predict the move of air-born virus by ventilation system at hospital. Simulation results showed that pressure distribution was -372.05Pa ~ -3.45 Pa at 1st floor incase of only used mechanical exhaust at bathroom, shower stall, storage, kitchen etc.. if ventilation switch from used mechanical exhaust to mechanical exhaust & mechanical supply. Simulation results showed that pressure distribution was -336.44Pa at stair hall < -0.2Pa at bathroom < mean 1.19Pa at other room. So simulation results showed that using all of the mechanical supply and mechanical exhaust was more effective then the mechanical exhaust for maintain the pressure distribution in hospital. It was also showed that when using the mechanical supply and mechanical exhaust more effectively prevention of air born virus diffusion.

Ventilation System Control by Location-Aware of Pollution Source (오염발생원의 위치인식에 의한 환기장치 제어방안)

  • Han, H.;Han, Jung-Il;Kwon, Yong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.405-410
    • /
    • 2006
  • This paper presents a control algorithm of supply and exhaust diffusers by recognizing a contaminant source location. CFD analysis has been conducted to calculate steady state airflow and concentration distributions in a model room, which has two supply and two exhaust openings on the ceiling. Calculations have been performed for five cases out of nine different ventilation modes by combining on/off control of the supply and exhaust openings. Local mean residual life times are obtained and compared at 9 internal points for each ventilation case. Depending on the contaminant source location, the ventilation system is operated at an optimum ventilation mode, which can results in maximum exhaust performance.

  • PDF

An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces (일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.178-185
    • /
    • 1998
  • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

  • PDF

A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen (공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.