• Title/Summary/Keyword: superconducting power machine

Search Result 40, Processing Time 0.032 seconds

Transport current Losses of the HTS Stacked Tapes at Various Gap between Tapes (고온초전도 적층선재에서의 층간 거리에 따른 전송전류 손실)

  • 임형우;이승욱;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.254-256
    • /
    • 2003
  • AC loss is one of the important superconducting power machine that we have to consider deeply using the stack wires with the HTS. AC magnetic field is occurred around the wires when the electric current is conducted to the stack wires. It also brings electric field to the wires and occurs self field loss, whose quantity is appeared differently by distance of the stack wires. In this paper, transport current losses of a stack short sample of HTS were compared with Norris equation and measured value.

  • PDF

Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors (적층 수에 따른 YBCO 선재의 전송전류 손실 특성)

  • Han, Byung-Wook;Lim, Hee-Hyun;Kang, Myung-Hun;Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1265-1266
    • /
    • 2006
  • Multi-stacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF

Critical Current Degradation Characteristics by Temperature Difference of L$N_2$-Normal in Repetitive Bending Strain of High Temperature Superconducting Tape (고온 초전도 선재의 굽힘횟수와 온도차에 의한 임계전류저하특성)

  • 김해준;김석환;송규정;김해종;배준한;조전욱;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.274-277
    • /
    • 2003
  • Critical current(Ic) degradation of HTS tapes after bending is one of the hottest issues in HTS development and application studies. Many people are measuring Ic degradations for effect of bending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the Ic degradation after repetitive bending. at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC) and superconductiing tapes that strain is imposed measured critical current by temperature difference of L$N_2$ and normal temperature. Like this, critical current could measure that degradation about 1~3% by temperature difference. These results will amount the most important basis data in power electric machine of superconductivity cable, magnet, etc that winding work is require.

  • PDF

Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors (적층 수에 따른 YBCO 선재의 전송전류 손실 특성)

  • Han, Byung-Wook;Lim, Hee-Hyun;Kang, Myung-Hun;Lim, Hyoung-Woo;Cha, Guee-Woo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1725-1726
    • /
    • 2006
  • Multi-stacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

The a.c. losses in (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed superconducting tapes (Bi-2223 고온 초전도 선재의 교류손실에 관한 연구)

  • Kang, Hyoung-Ku;Chu, Yong;Lee, Chan-Joo;Ko, Tae-Kuk;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.822-824
    • /
    • 2000
  • To apply HTS to AC devices, it is necessary that study theoretically and experimentally to analyze the AC losses. It should be investigated the theoretical mechanisms precede the actual experiments. Because the AC losses cause some complicated troubles in AC machines, we can design the machines properly. In this study, firstly we analyze the basic cause of AC losses by investigating the several loss factors, secondly measure the AC losses of HTS by using Magnetization. Technique and this results show that AC losses of HTS is tenuous than those of general materials used in power system. Consequently we can compare the actual results with the theoretical results. And we find that AC losses of HTS are related to the amplitude of external magnetic field and the frequency. Through this study, we find that it is possible to apply the results by Magnetization. Technique to the AC power system, to the design of AC machine, to design of HTS proper to the foretold AC losses.

  • PDF

Conceptual design of cooling anchor for current lead on HTS field coils

  • Hyeon, C.J.;Kim, J.H.;Quach, H.L.;Chae, S.H.;Yoon, Y.S.;Lee, J.;Han, S.H.;Jeon, H.;Choi, Y.H.;Lee, H.G.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.38-43
    • /
    • 2017
  • The role of current lead in high-temperature superconducting synchronous machine (HTSSM) is to function as a power supply by connecting the power supply unit at room temperature with the HTS field coils at cryogenic temperature. Such physical and electrical connection causes conduction and Joule-heating losses, which are major thermal losses of HTSSM rotors. To ensure definite stability and economic feasibility of HTS field coils, quickly and smoothly cooling down the current lead is a key design technology. Therefore, in this paper, we introduce a novel concept of a cooling anchor to enhance the cooling performance of a metal current lead. The technical concept of this technology is the simultaneously chilling and supporting the current lead. First, the structure of the current lead and cooling anchor were conceptually designed for field coils for a 1.5 MW-class HTSSM. Then, the effect of this installation on the thermal characteristics of HTS coils was investigated by 3D finite element analysis.

Characteristics of Surface Flashover of spacer in Liquid Nitrogen (액체 질소중에서 고체 Spacer에 의한 연면 방전특성)

  • Kim, Y.S.;Back, S.M.;Lee, B.S.;Jang, H.M.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.912-914
    • /
    • 1999
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconducting power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen($LN_2$). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in $LN_2$, and last step is comparison the result of this research with that of fully immersed in $LN_2$ and at cryogenic temperature gaseous nitrogen($GN_2$). This result presented that surface flashover voltage along solid spacer half immersed in $LN_2$ was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10 mm. In the case of t>10 mm, however, spacer flashover voltage was equal to that obtained in $GN_2$ at cryogenic temperature.

  • PDF

Fabrication of 250 m class Bi-2223/Ag HTS Tapes (250 m 급 Bi-2223/Ag 고온 초전도선재 제조)

  • Ha, H.S.;Oh, S.S.;Ha, D.W.;Jang, H.M.;Kim, S.C.;Song, K.J.;Park, C.;Kwon, Y.K.;Ryu, K.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

Establishment of CTE Measurement Procedure for PPLP at 77 K for HTS Power Cables using Double Extensometers

  • Dedicatoria, Marlon J.;Dizon, John Ryan C.;Shin, Hyung-Seop;Sim, Ki-Duk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.24-27
    • /
    • 2012
  • The measurement of the coefficient of thermal expansion (CTE) of polypropylene laminated paper (PPLP) as electric insulating material is important for its practical superconducting device application. The thermal strain induced to HTS tapes and its insulating material during cooling from room temperature might largely affect the critical current ($I_c$) of HTS tapes. In this study, the thermal contraction of PPLP material was measured during cooling from 300 K to 77 K using double extensometers. Initially, the CTE of a brass tape was measured and it was compared with a reference data. It was found that the measured thermal expansion data of the brass material approaches that of the reference one. Based on the results, it was then confirmed that the measurement technique could be applied to thin and flexible samples. Therefore, the same measurement procedure was applied to PPLP material using double extensometers. As a result, the linear CTE of the PPLP at 77 K has been measured to be ${\sim}15.3{\times}10^{-6}/K$. Also, it was found that the thermal contraction characteristics of PPLP was dominated by polypropylene on the cross direction (higher thermal contraction) while it was dominated by Kraft paper on the machine direction (lower thermal contraction). Overall, this measurement procedure could be adopted for the determination of CTE of flexible materials such as PPLP.