• 제목/요약/키워드: suction devices

검색결과 46건 처리시간 0.021초

흡입관 주위에 형성된 공기차단막이 흡입성능에 미치는 영향 (Effect of the Suction Performance by the Air-Curtain Blowing around a Suction Duct)

  • 조종현;김재실;조수용
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.25-32
    • /
    • 2009
  • A study is conducted to improve the suction performance on suction devices which are used to remove polluted air generated by welding or machining process in a spacious working place of industry. Air-curtain is applied around the inlet of suction duct to interrupt the inflow of fresh air from the downstream region where is located opposite to the polluted air source. Two different air-curtain devices, such as a $45^{\circ}$ backward and a fully backward, are adopted. Suction region is experimentally investigated by measuring the suction velocities using a hot-wire anemometer. Contours of the suction velocity are compared with the computed results. The suction condition is selected to 110,000 Reynolds number which is widely used on typical suction devices, and a width of blowing passage for creating the air-curtain is chosen to 9.38% of the suction duct diameter. The experimental results show that the suction performance obtained with the $45^{\circ}$ backward air-curtain was better than that obtained with the fully backward air-curtain. On the suction duct using the $45^{\circ}$ backward air-curtain, the suction region estimated on basis of the 0.4m/sec is improved by 66% at the same input power.

고유진동수 기반 석션기초의 지반구속효과 분석 (Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement)

  • 유무성;이준신;이종화;서윤호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

초보자에서 후두튜브기도기와 후두마스크기도기의 삽관 비교 - 마네킨 연구 - (Comparison between laryngeal tube suction II and laryngeal mask airway in novice users - A manikin study -)

  • 황지영;조근자
    • 한국응급구조학회지
    • /
    • 제16권3호
    • /
    • pp.19-28
    • /
    • 2012
  • Purpose : The present study was designed to provide basic data for advanced pre-hospital airway management by comparing the insertion time and success rate between laryngeal tube suction II (LTS II) and laryngeal mask airway (LMA) in a manikin. Methods : A total of 32 participants were novice users to both of devices among paramedic students. After taking the introductory lecture and demonstrations, the participants made an attempt to insert the LTS II and LMA to compare the insertion time and success rate. They marked the easiness of insertion of the score ranged from 1 to 10 score scale and preference of the two devices. Results : The insertion time of the LTS II was significantly shorter than that of the LMA (p =.000). There was no significant difference between LTS II and LMA in the success rate. In the easiness of insertion, the score of LTS II $(8.47{\pm}1.41score)$ was significantly higher than that of LMA $(7.19{\pm}1.98score)$(p =.001). The preference of LTS II (75%) was much higher than that of LMA (25%). Conclusion : The manikin study data showed that the LTS II may be a good alternative airway device for providing and maintaining a patent airway.

퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출 (Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method)

  • 박승규;최성진
    • 한국지능시스템학회논문지
    • /
    • 제22권4호
    • /
    • pp.500-506
    • /
    • 2012
  • 좌심실보조장치의 모델과 안전한 장치 구동을 위한 흡입현상 검출을 위한 방법을 제안한다. 좌심실보조장치인 축류혈액펌프는 심장에 문제가 있는 환자를 보조하기 위하여 사용되어 왔다. 축류혈액펌프는 비맥동성 펌프이며, 맥동성 펌프에 비하여 작은 크기와 효율성과 같은 장점이 있으나, 안전한 펌프 운전 조건을 결정하는 데 어려움이 있다. 축류혈액펌프는 정상상태와 흡입상태와 같은 상이한 펌프 동작 상태를 가지며, 이는 좌심실에서 흡입현상 발생여부에 좌우된다. 퍼지 subtractive 클러스터링 기법을 이용하여, 이와 같은 동작 특성을 가지는 축류혈액펌프 모델을 개발하며, 개발한 펌프 모델을 이용하여 흡입현상 발생 전후의 펌프 혈류량을 추정한다. 또한 퍼지 subtractive 클러스터링 기법을 이용하여 좌심실에서 흡입현상 발생여부를 감지할 수 있는 흡입현상 검출 모델을 개발한다.

분사펌프의 흡입관 각도 변화에 따른 유동특성 (Flow Characteristics of a Jet Pump by the Angle Variation of a Suction Pipe)

  • 김노형
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.61-67
    • /
    • 2016
  • In this study, STAR-CD-based CFD techniques was used to analyze velocity distribution and pressure distribution according to the variation of angels at $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$ a suction pipe when inlet velocity condition is 1 m/s. SIMPLE maritime law used for analytical algorithm and the results of CFD analysis evaluated by particle image velocimetry (PIV). The results of CFD analysis in this study have revealed that the optimal angle of a suction pipe for a jet pump is $90^{\circ}$ and the PIV test has showed the same results. Therefore, it is thought that when CFD is used to analyze the flow characteristics of a jet pump it would be possible to produce optimal designs of its devices.

금속관 내부의 음압유량 향상을 위한 기하학적 디자인 및 SLIPS 윤활 (Geometrical Design and SLIPS Lubrication for Enhancement of Negative-pressure-driven Internal Flow Rate in Metal Pipes)

  • 김동근;장창환;김성재;김대겸;김산하
    • Tribology and Lubricants
    • /
    • 제37권6호
    • /
    • pp.253-260
    • /
    • 2021
  • Metal pipes are used in a wide range of applications, from plumbing systems of large construction sites to small devices such as medical tools. When a liquid is enforced to flow through a metal pipe, a higher flow rate is beneficial for higher efficiency. Using high pressures can enhance the flow rate yet can be harmful for medical applications. Thus, we consider an optimal geometrical design to increase the flow rate in medical devices. In this study, we focus on cannulas, which are widely used small metal pipes for surgical procedures, such as liposuction. We characterize the internal flow rate driven by a negative pressure and explore its dependence on the key design parameters. We quantitatively analyze the suction characteristics for each design variable by conducting computational fluid dynamics simulations. In addition, we build a suction performance measurement system which enables the translational motion of cannulas with pre-programmed velocity for experimental validation. The inner diameter, section geometry, and hole configuration are the design factors to be evaluated. The effect of the inner diameter dominates over that of section geometry and hole configuration. In addition, the circular tube shape provides the maximum flow rate among the elliptical geometries. Once the flow rate exceeds a critical value, the rate becomes independent of the number and width of the suction holes. Finally, we introduce a slippery liquid-infused nanoporous surface (SLIPS) coating using nanoparticles and hydrophobic lubricants that effectively improves the flow rate and antifouling property of cannulas without altering the geometrical design parameter.

불포화토의 함수특성 측정 (Measurements of Soil Water Characteristics for Different Unsaturated Soils)

  • 김상규;류지협;송진규
    • 한국지반공학회지:지반
    • /
    • 제12권6호
    • /
    • pp.139-152
    • /
    • 1996
  • 불포화토에 대한 흐름문제를 해석하기 위해서는 비선형으로 표시되는 부간극수압과 함수비 사이의 관계를 알아야 한다. 본 논문에서는 주문진 표준사, 한강모래 및 세립함유율이 다른 몇가지 화강풍화토에 대하여 2가지 실험기구로 이 관계를 측정하고 그 특성을 규명하였다. 여기서 얻은 자료를 이용하여 이 관계를 실험없이 추정가능한 경험식에 쓰이는 경험상수들을 얻었다. 몇가지 경험식중 van Genuchten(1980)의 것이 실험곡선과 잘 부합된다. 화강풍화토에 대해서는 세립함유율(No.200체 통과율)의 증가에 따라 경험상수들도 거의 일정하게 증가하는 경향을 보인다는 것을 알게 되었다. 따라서 이 관계를 이용하여 화강풍화토에 대한 함수특성곡선의 추정이 가능하다.

  • PDF

치과용 통합공급장치를 위한 안드로이드 운영체제가 내장된 제어시스템 개발 (Development of Control System with Android Operation System for Dentistry Integrated Device)

  • 황기현
    • 한국정보통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.635-642
    • /
    • 2012
  • 본 논문에서는 치과용 통합공급장치를 실시간으로 제어 및 모니터링할 수 있고 그 결과를 Wi-Fi 무선랜 통신을 통해 송수신이 가능한 제어시스템을 개발하였다. 개발한 제어시스템은 안드로이드 운영체제를 내장하기 위해 S3C6410 ARM 칩을 이용하여 설계하였다. 개발한 제어시스템은 Wi-Fi 통신, RS485, 리녹스 2.6 및 안드로이드 운영체제 2.0을 내장하도록 보드를 개발하였다. 개발한 제어시스템은 치과용 통합공급장치에 내장되어 있는 정수기, 컴프레서, 석션을 실시간으로 제어하였다. 실험결과, 개발한 제어시스템은 각 제어기 모듈과 연계하여 정수기, 석션 및 컴프레서를 실시간으로 제어하였고, 그 상태 값을 RS485 통신을 이용하여 제어시스템에 실시간으로 표시하였다.

태양광발전시설 무인 유지보수 로봇 개발 (Development of Unmanned Cleaning Robot for Photovoltaic Panels)

  • 이현규;이상순
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.144-149
    • /
    • 2019
  • This paper describes the results of a study on the unmanned maintenance robot that simultaneously performs the cleaning and inspection of the photovoltaic panels. The robot has a special adsorptive device, an infrared sensor, a vacuum level sensor and a camera. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed, and the required design and control of the adsorption system are suggested. The robot was designed and manufactured to operate stably by using the presented results. Next, the normal force between the panel and the wheel was measured to confirm that the robot was manufactured and operated as intended, and the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean and inspect sloped panels.

Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia

  • Jung, Chang Young;Kim, Tae Gon;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.42-47
    • /
    • 2017
  • Background Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition. Methods The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study. Results Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage. Conclusions Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.