• 제목/요약/키워드: sub-health center

검색결과 456건 처리시간 0.026초

The GABAB receptor associates with regulators of G-protein signaling 4 protein in the mouse prefrontal cortex and hypothalamus

  • Kim, Gyeongwha;Jung, Soonwoong;Son, Hyeonwi;Kim, Sujeong;Choi, Jungil;Lee, Dong Hoon;Roh, Gu Seob;Kang, Sang Soo;Cho, Gyeong Jae;Choi, Wan Sung;Kim, Hyun Joon
    • BMB Reports
    • /
    • 제47권6호
    • /
    • pp.324-329
    • /
    • 2014
  • Regulators of G-protein signaling (RGS) proteins regulate certain G-protein-coupled receptor (GPCR)-mediated signaling pathways. The GABAB receptor ($GABA_BR$) is a GPCR that plays a role in the stress response. Previous studies indicate that acute immobilization stress (AIS) decreases RGS4 in the prefrontal cortex (PFC) and hypothalamus (HY) and suggest the possibility of a signal complex composed of RGS4 and $GABA_BR$. Therefore, in the present study, we tested whether RGS4 associates with $GABA_BR$ in these brain regions. We found the co-localization of RGS4 and $GABA_BR$ subtypes in the PFC and HY using double immunohistochemistry and confirmed a direct association between $GABA_{B2}R$ and RGS4 proteins using co-immunoprecipitation. Furthermore, we found that AIS decreased the amount of RGS4 bound to $GABA_{B2}R$ and the number of double-positive cells. These results indicate that $GABA_BR$ forms a signal complex with RGS4 and suggests that RGS4 is a regulator of $GABA_BR$.

Optimization of Multi-Atlas Segmentation with Joint Label Fusion Algorithm for Automatic Segmentation in Prostate MR Imaging

  • Choi, Yoon Ho;Kim, Jae-Hun;Kim, Chan Kyo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.123-131
    • /
    • 2020
  • Purpose: Joint label fusion (JLF) is a popular multi-atlas-based segmentation algorithm, which compensates for dependent errors that may exist between atlases. However, in order to get good segmentation results, it is very important to set the several free parameters of the algorithm to optimal values. In this study, we first investigate the feasibility of a JLF algorithm for prostate segmentation in MR images, and then suggest the optimal set of parameters for the automatic prostate segmentation by validating the results of each parameter combination. Materials and Methods: We acquired T2-weighted prostate MR images from 20 normal heathy volunteers and did a series of cross validations for every set of parameters of JLF. In each case, the atlases were rigidly registered for the target image. Then, we calculated their voting weights for label fusion from each combination of JLF's parameters (rpxy, rpz, rsxy, rsz, β). We evaluated the segmentation performances by five validation metrics of the Prostate MR Image Segmentation challenge. Results: As the number of voxels participating in the voting weight calculation and the number of referenced atlases is increased, the overall segmentation performance is gradually improved. The JLF algorithm showed the best results for dice similarity coefficient, 0.8495 ± 0.0392; relative volume difference, 15.2353 ± 17.2350; absolute relative volume difference, 18.8710 ± 13.1546; 95% Hausdorff distance, 7.2366 ± 1.8502; and average boundary distance, 2.2107 ± 0.4972; in parameters of rpxy = 10, rpz = 1, rsxy = 3, rsz = 1, and β = 3. Conclusion: The evaluated results showed the feasibility of the JLF algorithm for automatic segmentation of prostate MRI. This empirical analysis of segmentation results by label fusion allows for the appropriate setting of parameters.

간호대학생의 전공만족도와 보건소실습 중요도 인식과 수행도의 IPA에 관한 연구 (A Study on the IPA of Nursing Students' Major Satisfaction and Importance Perception and Performance of Public Health Center Practice)

  • 김은재
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.39-49
    • /
    • 2023
  • 본 연구는 간호대학생의 보건소 실습에 전공만족도 및 실습의 중요도 인식과 수행도을 분석하고 보건소의 실습내용에 대한 개선방안을 파악하고자 J시의 간호대학생 217명을 대상으로 자료를 수집하였다. 수집된 자료는 SPSS WIN 25.0을 이용하여 분석하였으며, 연구결과는 전공만족도와 보건소 임상실습 수행도와는 정적상관(r=.55, p<.001)을 가지는 것으로 나타났으며, 수행도의 하위요인 모두와 정적 상관(r=.41~.54, p<.001)을 보였다. 특히 하위의 요인 중 실습을 통한 내적 성장과 이론의 실제 적용과의 상관관계는(r=.54~.56, p<.001)으로 상관성이 높은 요인이었다. 간호학생들의 전공만족도를 향상시키기 위해서는 이론 공부가 선행되어야 하며, 영역별 분석을 통해 간호대학생이 의 간호대학생들의 정체성과 내적 성장을 통한 만족감을 얻기 위해서는 보건소 실습을 하는 동안 실습지도자는 다양한 네트워크를 구축하며 간호대학생들과의 원할한 의사소통에 최선을 다하며, 지역사회의 보건소 실습 환경개선을 위해 실습 전·후 실습기관과의 간담회를 통한 다양한 의견들의 제시가 이루어지도록하며, 간호대학생들의 보건소 실습이 원활하게 수행되기 위해서는 실습지도교원은 간호대학생이 보건소 실습을 하기 전 실습관련 사전 학습이 필요하다는 개선점을 도출하였다.

Rat를 이용 1-Bromopropane의 급성 및 아급성 흡입독성 연구 (Study on the Acute and Sub-Acute Inhalation Toxicity of 1-Bromopropane in SD Rats)

  • 김현영;정재황;정용현;이용묵;서길수
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.272-288
    • /
    • 1998
  • The purpose of this study was to investigate the acute(4 hrs) and repeated-dose(6 hrs a day, 5 days a week, 8 weeks) toxic effects of 1-bromopropane(1-BP) on Sprague-Dawley (SD) rats which were treated by inhalation. The results were as follows ; 1. The median lethal concentration($LC_{50}$) was estimated 14,374 ppm(confidence limit 95% ; 13,624~15,596 ppm) in acute inhalation. Abnormal clinical signs related to the 1-BP were not observed with the acute inhalation dose. Gross findings of necropsy revealed no evidence of specific toxicity related to the 1-BP. 2. By sub-acute inhalation the body weights of male and female were significantly reduced(p<0.001) by the dose of 1,800 ppm compared with control group, while the relative weights of liver were significantly increased(p<0.001) in both sexes. However there were no significant variation in food consumption, urine biochemistry, hematology and blood biochemistry for the exposed rats compared with the control rats. Abnormal clinical signs and gross findings of necropsy related to the 1-BP were not shown. No toxicologic lesions were observed by the histopathological test.

  • PDF

지리정보시스템(GIS) 및 존재인구를 이용한 초미세먼지(PM2.5) 노출평가 (Existing Population Exposure Assessment Using PM2.5 Concentration and the Geographic Information System)

  • 우재민;민기홍;김동준;조만수;성경화;원정일;이채관;신지훈;양원호
    • 한국환경보건학회지
    • /
    • 제48권6호
    • /
    • pp.298-305
    • /
    • 2022
  • Background: The concentration of air pollutants as measured by the Air Quality Monitoring System (AQMS) is not an accurate population exposure level since actual human activities and temporal and spatial variability need to be considered. Therefore, to increase the accuracy of exposure assessment, the population should be considered. However, it is difficult to obtain population data due to limitations such as personal information. Objectives: The existing population defined in this study is the number of people in each region's grid. The purpose is to provide a methodology for evaluating exposure to PM2.5 through existing population data provided by the National Geographic Information Institute. Methods: The selected study period was from October 26 to October 28, 2021. Using PM2.5 concentration data measured at the Sensor-based Air Monitoring Station (SAMS) installed in Guro-gu and Wonju-si, the concentration for each grid was estimated by applying inverse distance weights through QGIS version 3.22. Considering the existing population, population-weighted average concentration (PWAC) was calculated and the exposure level of the population was compared by region. Results: The outdoor PM2.5 concentration as measured through the SAMS was high in Wonju-si on all three days. Wonju-si showed an average 22% higher PWAC than Guro-gu. As a result of comparing the PWAC and outdoor PM2.5 concentration by region, the PWAC in Guro-gu was 1~2% higher than the observed value, but it was almost the same. Conversely, observations of Wonju-si were 10.1%, 11.3%, and 8.2% higher than PWAC. Conclusions: It is expected that the Geographic Information System (GIS) method and the existing population will be used to evaluate the exposure level of a population with a narrow activity radius in further research. In addition, based on this study, it is judged that research on exposure to environmental pollutants and risk assessment methods should be expanded.

천식 환자 가정 내 굽기조리 활동에 의한 실내 미세먼지(PM2.5) 농도 수준의 변화 (Impact of Indoor Pan-frying Cooking Activity on Change of Indoor PMPM2.5 Concentration Level in Asthmatics' Homes)

  • 박수정;박춘식;임대현;이상운;장소영;유솔;김성렬
    • 한국환경과학회지
    • /
    • 제29권1호
    • /
    • pp.109-117
    • /
    • 2020
  • Asthmatics are more susceptible to fine particulate matters (PM2.5), compared to the general population. It has been reported that indoor PM2.5 is mainly generated by combustion of fossil fuels, meat or fish In particular, asthmatics are known to be more susceptible to indoor PM2.5 because 65~95% of child or adult asthmatics stay inside the house. Thus, understanding the association between indoor activity patterns and variations in indoor PM2.5 levels is important. The purpose of this study is to determine the distribution of hourly indoor PM2.5 concentrations in asthmatics' homes, and to evaluate its association with pan-frying cooking activity patterns, the most common PM2.5 emission related activity. From November 2017 to February 2018, real-time PM2.5 concentrations were measured in the living room of each asthmatic's house (n = 35) for three weeks at 1 minute intervals. At the same time, self-reported daily activity patterns, hourly proportion (%) of cooking activities, were also recorded every hour over three weeks for each patient. In this study, we provided quantitative evidence that the distribution patterns of indoor hourly PM2.5 concentrations were associated with indoor cooking activities, especially in the homes of adult asthmatics. In addition, we observed that PM2.5 emitted by pan-frying could maintain even over up to 2 hour lagtime.

Urban Greening: A Sustainable Method for Particulate Matter (PM) Reduction

  • Sanghee Park;Myeong Ja Kwak;Jongkyu Lee;Yea Ji Lim;Handong Kim;Su Gyeong Jeong;Joung-a Son;Hanna Chang;Sun Mi Je;Chang-Young Oh;Kyongha Kim;Su Young Woo
    • 한국산림과학회지
    • /
    • 제112권1호
    • /
    • pp.1-10
    • /
    • 2023
  • Urbanization and industrialization associated with rapid economic development have resulted in air pollution in urban areas, which adversely affects human health and the environment around the world. Growing awareness of the health effects of airborne particulate matter (PM) has led to the emergence of urban greening as a promising eco-friendly, nature-based solution to reduce the concentration of PM (especially PM2.5) to which individuals are exposed, thereby promoting public health. In this review, we highlight fundamental insights about PM and recent research on the ability of urban greening to capture PM. Reports from the scientific literature on PM published from 1992 to 2021 were retrieved from Google Scholar. Here, we explore some of the main complex relationships between leaf traits and the ability to retain PM for research or management to optimize greenspaces.

Factors Associated With Failure of Health System Reform: A Systematic Review and Meta-synthesis

  • Mahboubeh Bayat;Tahereh Kashkalani;Mahmoud Khodadost;Azad Shokri;Hamed Fattahi;Faeze Ghasemi Seproo;Fatemeh Younesi;Roghayeh Khalilnezhad
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권2호
    • /
    • pp.128-144
    • /
    • 2023
  • Objectives: The health system reform process is highly political and controversial, and in most cases, it fails to realize its intended goals. This study was conducted to synthesize factors underlying the failure of health system reforms. Methods: In this systematic review and meta-synthesis, we searched 9 international and regional databases to identify qualitative and mixed-methods studies published up to December 2019. Using thematic synthesis, we analyzed the data. We utilized the Standards for Reporting Qualitative Research checklist for quality assessment. Results: After application of the inclusion and exclusion criteria, 40 of 1837 articles were included in the content analysis. The identified factors were organized into 7 main themes and 32 sub-themes. The main themes included: (1) reforms initiators' attitudes and knowledge; (2) weakness of political support; (3) lack of interest group support; (4) insufficient comprehensiveness of the reform; (5) problems related to the implementation of the reform; (6) harmful consequences of reform implementation; and (7) the political, economic, cultural, and social conditions of the society in which the reform takes place. Conclusions: Health system reform is a deep and extensive process, and shortcomings and weaknesses in each step have overcome health reform attempts in many countries. Awareness of these failure factors and appropriate responses to these issues can help policymakers properly plan and implement future reform programs and achieve the ultimate goals of reform: to improve the quantity and quality of health services and the health of society.

시판용 미생물탈취제를 이용한 하수 악취 내 황화수소 저감에 관한 실험적 연구 (Experimental Study on Hydrogen Sulfide Abatement in Sewage Odor Using Microbial Deodorants on the Market)

  • 박상진;권수열
    • 한국환경보건학회지
    • /
    • 제46권2호
    • /
    • pp.170-183
    • /
    • 2020
  • Objectives: This study was conducted to estimate a technology to reduce hydrogen sulfide (H2S) in sewage odor using microbial deodorant. Methods: After injecting five commercially available microbial deodorants into fresh sewage, the concentration of hydrogen sulfide over time was measured using the headspace method. H2S concentration in odor samples was measured using gas chromatograph/FPD. Calculated odor concentration and calculated odor intensity by H2S concentration remaining after treatment with microbial deodorant were evaluated theoretically. Results: The rate of H2S abatement by microbial deodorant differed depending on the experimental conditions and the type of deodorant, but it was found to range from 63 to 82%. Especially, two deodorants showed high H2S reduction rates of over 80% on average. However, based on the best deodorant, the theoretically calculated odor concentration by H2S after microbial deodorant treatment was 4,400 OUk, and the theoretical odor intensity was also rated at 4 degrees or higher. Conclusions: In conclusion, microbial deodorant is considered to have a relatively high effect on reducing H2S in sewage odor. However, even after treatment with microbial deodorant, calculated odor concentration and calculated odor intensity were relatively high. This is thought to be caused by other odorous substances besides H2S.