• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.042 seconds

A fast precise integration method for structural dynamics problems

  • Gao, Q.;Wu, F.;Zhang, H.W.;Zhong, W.X.;Howson, W.P.;Williams, F.W.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • A fast precise integration method (FPIM) is proposed for solving structural dynamics problems. It is based on the original precise integration method (PIM) that utilizes the sparse nature of the system matrices and especially the physical features found in structural dynamics problems. A physical interpretation of the matrix exponential is given, which leads to an efficient algorithm for both its evaluation and subsequently the solution of large-scale structural dynamics problems. The proposed algorithm is accurate, efficient and requires less computer storage than previous techniques.

Online automatic structural health assessment of the Shanghai Tower

  • Zhang, Qilin;Tang, Xiaoxiang;Wu, Jie;Yang, Bin
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.319-332
    • /
    • 2019
  • Structural health monitoring (SHM) is of great importance to super high-rise buildings. The Shanghai Tower is currently the tallest building in China, and a complete SHM system was simultaneously constructed at the beginning of the construction of the tower. Due to the variety of sensor types and the large number of measurement points in the SHM system, an online automatic structural health assessment method with few computations and no manual intervention is needed. This paper introduces a structural health assessment method for the Shanghai Tower that uses the coefficients of an autoregressive (AR) time series model as structural state indicators. An analysis of collected data indicates that the coefficients of the AR model are affected by environmental factors, and the principal component analysis method is used to remove the influence of environmental factors. Finally, the control chart method is used to track the changes in structural state indicators, and a plan for online automatic structure health state evaluation is proposed. This method is applied to long-term acceleration and inclination data from the Shanghai Tower and successfully identifies the changes in the structural state. Overall, the structural state indicators of the Shanghai Tower are stable, and the structure is in a healthy state.

Fatigue and Robust Analysis for Improving the Suspended Pedal of Vehicles (차량용 서스펜디드 페달 구조체의 피로 내구 분석 및 설계 개선)

  • Lee, Woo-Hyung;Hwang, Bum-Chul;Kim, Chul;Bae, Won-Byong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.105-111
    • /
    • 2009
  • This study was carried out to evaluate structural stability of the suspended plastic pedal used in vehicles and to predict its fatigue life with the results obtained from finite element analysis. And also shape optimization was performed to reduce its weight. Structural analysis of the suspended plastic pedal was based on the evaluation tests such as static test, stiffness test, and fatigue test in the actual field, which were frequently carried out in the companies manufacturing plastic pedals. The evaluation for the plastic pedal was carried out by structural and fatigue analyses using a commercial FEA program and according to it, maximum stress and strain and fatigue life of the pedal satisfied all the requirements in the evaluation tests. The results of structural analysis of the suspended plastic pedal were used in the fatigue analysis. Fatigue test was performed to verify validity of the theoretical fatigue life of the plastic pedal. And the life by theoretical calculation was in good agreement with that by the experiment. Object function for optimizing shape of the plastic pedal is its volume, and total volume of the plastic pedal was reduced to about 11.7% through shape optimization.

Damage Evaluation of a Railroad Bridge Using Time-domain Deflection Shape (시간영역 변형형상을 이용한 철도교량의 손상평가)

  • Choi, Sang-Hyun;Lim, Nam-Hyoung;Kang, Young-Jong
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.129-134
    • /
    • 2009
  • To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.

Structural health monitoring of a cable-stayed bridge using smart sensor technology: deployment and evaluation

  • Jang, Shinae;Jo, Hongki;Cho, Soojin;Mechitov, Kirill;Rice, Jennifer A.;Sim, Sung-Han;Jung, Hyung-Jo;Yun, Chung-Bangm;Spencer, Billie F. Jr.;Agha, Gul
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.439-459
    • /
    • 2010
  • Structural health monitoring (SHM) of civil infrastructure using wireless smart sensor networks (WSSNs) has received significant public attention in recent years. The benefits of WSSNs are that they are low-cost, easy to install, and provide effective data management via on-board computation. This paper reports on the deployment and evaluation of a state-of-the-art WSSN on the new Jindo Bridge, a cable-stayed bridge in South Korea with a 344-m main span and two 70-m side spans. The central components of the WSSN deployment are the Imote2 smart sensor platforms, a custom-designed multimetric sensor boards, base stations, and software provided by the Illinois Structural Health Monitoring Project (ISHMP) Services Toolsuite. In total, 70 sensor nodes and two base stations have been deployed to monitor the bridge using an autonomous SHM application with excessive wind and vibration triggering the system to initiate monitoring. Additionally, the performance of the system is evaluated in terms of hardware durability, software stability, power consumption and energy harvesting capabilities. The Jindo Bridge SHM system constitutes the largest deployment of wireless smart sensors for civil infrastructure monitoring to date. This deployment demonstrates the strong potential of WSSNs for monitoring of large scale civil infrastructure.

Two-way Shear Strength Evaluation of Transfer Slab-Column Connections Through Nonlinear FE Analysis (비선형유한요소해석을 통한 전이슬래브-기둥 접합부의 2면 전단강도 평가)

  • Jeong, Seong-Hun;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.315-329
    • /
    • 2018
  • Recently, RC transfer slab systems have been used widely to construct high-rise wall-type apartments for securing parking space or public space. However, it is problem that the design method and structural performance evaluation method developed for thin RC flat slab are still used in the design of the transfer slab whose thickness is very thick and therefore structural behavior is expected to be different from RC flat slab. Thus, for the rational design of the transfer slab, the ultimate shear behavior of the RC transfer slab system is required to be analyzed properly. Accordingly, in the present study, the two-way shear behavior of the transfer slab was analyzed using nonlinear FEM according to various design parameters such as thickness of the transfer slab, strength of concrete, shear span ratio, and reinforcement ratio. In addition, the two-way shear strength evaluations of RC transfer slab by the existing evaluation methods were verified by comparing those with the results of nonlinear FEM analysis.

System-Level Seismic Fragility Evaluation of Bridge Considering Aging Effects (노후도를 고려한 교량의 시스템-수준 지진취약도 평가)

  • Kong, Sina;Moon, Jiho;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.149-158
    • /
    • 2022
  • As a bridge ages, its mechanical properties and structural performance deteriorate, degrading its seismic performance during a strong earthquake. In this study, the aging of piers and bridge bearings was quantified in several stages and reflected in the analysis model, enabling the evaluation of the member-level seismic fragility of these bearings. Moreover, by assuming that the failure mechanism of a bridge system is a series system, a method for evaluating the system-level seismic fragility based on the member-level seismic fragility analysis result is formulated and proposed. For piers with rubber and lead-rubber bearings (members vulnerable to aging effects), five quantitative degrees of aging (0, 5, 10, 25, and 40%) are assumed to evaluate the member-level seismic fragility. Then, based on the result, the system-level seismic fragility evaluation was implemented. The pier rather than the bridge bearing is observed to have a dominant effect on the system-level seismic fragility. This means that the seismic fragility of more vulnerable structural members has a dominant influence on the seismic fragility of the entire bridge system.

Relationships of Parent Brand Attitude and the Evaluation Level of Brand Extension by Distribution Channel Types (유통경로 유형별 모 브랜드태도와 브랜드확장 평가도의 관계)

  • Youn, Soung-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.349-359
    • /
    • 2009
  • This study analyzed the structural correlation between parent brand attitude, including attitude toward the advertisement, attitude toward the store and brand attitude, and brand extension evaluation, relationships among which are conceived as a brand extension evaluation process. The result of analysis, revealed statistical significances of the differences in the effect levels between attitude toward store and brand attitude, between brand attitude and brand extension evaluation level, and between brand extension evaluation level and purchase intention of an extended product depending on the choice of distribution channel type. Therefore the evaluation level of brand extension should be analyzed by structural relationship model based on the consumer behavior's viewpoint with distribution channel type and it can provide the important information for restructuring distribution channel and increase the level of the successful brand extension.