• Title/Summary/Keyword: structural evaluation

Search Result 4,837, Processing Time 0.033 seconds

Evaluation of Static Behaviour of Orthotropic Steel Deck Considering the Loading Patterns (하중재하 패턴을 고려한 강바닥판의 정적거동 평가)

  • Kim, Seok Tae;Huh, Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.98-106
    • /
    • 2011
  • The deck of steel box girder bridges is composed of deck plate, longitudinal rib, and transverse ribs. The orthotropic steel decks have high possibility to fatigue damage due to numbers of welded connection part, the heavy contact loadings, and the increase of repeated loadings. Generally, the local stress by the repeated loadings of heavy vehicles causes the orthotropic steel deck bridge to fatigue cracks. The increase of traffic volume and heavy vehicle loadings are promoted the possibility of fatigue cracks. Thus, it is important to exactly evaluate the structural behavior of bridge considering the contact loading area of heavy vehicles and real load patterns of heavy trucks which have effects on the bridge. This study estimated the effect of contact area of design loads and real traffic vehicles through the finite element analysis considering the real loading conditions. The finite element analysis carried out 4 cases of loading patterns in the orthotropic steel deck bridge. Also, analysis estimated the influence of contact area of real truck loadings by the existence of diaphragm plate. The result of finite element analysis indicated that single tire loadings of real trucks occurred higher local stress than one of design loadings, and especially the deck plate got the most influence by the single tire loading. It was found that the diaphragm attachment at joint part of longitudinal ribs and transverse ribs had no effects on the improvement of structural performance against fatigue resistance in elastic analysis.

Evaluation of Structural Performance of Reinforced Concrete Beams using Hybrid Retrofitting with Groove and Embedding FRP Rod and CFRP Sheet (표면요철 매입형 FRP봉과 CFRP시트를 복합 보강한 철근콘크리트 보의 구조성능 평가)

  • Ha, Gee-Joo;Ha, Young-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.41-49
    • /
    • 2014
  • In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using hybrid retrofitting with two materials (groove and embedding FRP rod, CFRP sheet) in existing reinforced concrete buildings. Seven reinforced concrete beams, retrofitted groove and embedding FRP rod (NER series) and groove and embedding FRP rod with CFRP sheet (NERL series), and standard specimen (NBS) were constructed and tested under monotonic loading. Design parameters of test specimens are the amount of groove and embedding FRP rod and lapping CFRP sheet. Test results showed that the maximum load carrying capacity of specimens with groove and embedding FRP rod and groove and embedding FRP rod with CFRP sheet (NERL series) were increased the by 12~46% and 22~77% respectively in comparison with the standard specimen NBS. Test specimens NER series were failed with the adhesion slip and concrete cover separation. And test specimens NERL series were failed with the adhesion slip due to the confining effect of lapping CFRP sheet.

A Theoretical Foundation for Examination of the Impacts of the Cross-Functional Integration Factors upon the New Product Development Performance (신제품개발 성과에 영향을 미치는 부서간 협력요인에 관한 이론적 토대)

  • Shim, Jong-Seop;Lee, Mun-Sung
    • Korean Business Review
    • /
    • v.11
    • /
    • pp.83-100
    • /
    • 1998
  • The objective of our study is to build a theoretical framework for the examination of impacts of cross-functional integration upon new product development performance(NPDP). For this purpose, we have concentrated our efforts on systematically delving into how cross-functional integration factors affect upon the interdepartmental cooperation and upon the NPDP while dividing those critical integration factors into the structural and the infra-structural ones. We have selected interdepartmental job-rotation, consigning of papers, and cross-functional teem meeting as structural cross-functional integration factors. On the other hand, we have chosen Quality Functional Deployment(QFD), Concurrent Engineering(CE), and Evaluation and Reward Systems as those infra-structural cross-functional integration factors. After identifying those integration factors, we have carefully searched the relationship between those integration factors and those cooperation variables (interdepartmental common goal, interdepartmental interactions, and common sharing of ideas and informations) to look into how they affect upon the NPDP. Among cross-functional integration and NPDP related studies, our study is the first to show systematically how strongly infra-structural integration factors affect upon the achievement of interdepartmental cooperation and the improvement of NPDP. Considering the limitation of our resources and time available for this research, we have limited our study to building only a theoretical framework for future empirical studies to look into how cross-functional integration variables are related with NPDP.

  • PDF

Evaluation of Seismic Behavior for RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 지진거동 평가)

  • Ko, Hyun;Kim, Hyun-Su;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.13-22
    • /
    • 2010
  • Masonry infill walls are frequently used as interior partitions and exterior walls in low- or middle- rise RC buildings. In the design and assessment of buildings, the infill walls are usually treated as non-structural elements and they are ignored in analytical models because they are assumed to be beneficial to the structural responses. Therefore, their influences on the structural response are ignored. In the case of buildings constructed in the USA in highly seismic regions, infill walls have a lower strength and stiffness than the boundary frames or they are separated from the boundary frames. Thus, the previously mentioned assumptions may be reasonable. However, these systems are not usually employed in most other countries. Therefore, the differences in the seismic behaviors of RC buildings with/without masonry infill walls, which are ignored in structural design, need to be investigated. In this study, structural analyses were performed for a masonry infilled low-rise RC moment-resisting frame. The infill walls were modeled as equivalent diagonal struts. The seismic behaviors of the RC moment-resisting frame with/without masonry infill walls were evaluated. From the analytical results, masonry infill walls can increase the global strength and stiffness of a structure. Consequently, the interstory drift ratio will decrease but seismic forces applied to the structure will increase more than the design seismic load because the natural period of the structure decreases. Partial damage of the infill walls by the floor causes vertical irregularity of the strength and stiffness.

Evaluation of Floor Acceleration for the Seismic Design of Non-Structural Elements according to the Core Shape (코어형태에 따른 비구조요소 내진설계를 위한 층가속도 평가)

  • Ki, Ho-Seok;Hong, Gi-Suop
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.1
    • /
    • pp.29-34
    • /
    • 2022
  • In this paper, the floor acceleration for the seismic design of non-structural elements was evaluated using the core shape as a planar variable. Linear time history analysis using 20 models with 5 different planes and 4 different floors on each plane depending on the change in the shape (position and specific gravity) of the core in the square biaxially symmetric plane was performed. The analysis confirmed that the torsional amplification of the floor acceleration was up to 1.7 times in the plane subjected to eccentricity depending on the position of the core, and the effect of torsion was the greatest in the middle floor of the structure. In a plane where only the specific gravity of the core was changed without eccentricity, when the period was less than 0.4694 s, the maximum floor acceleration decreased in the lower floors and increased in the upper floors as the period increased. Conversely, when the period was 0.4694 s or more, it was confirmed that the floor acceleration increased in the lower part and decreased in the upper part as the period increased.

Correlation Analysis of Load-carrying Capacity by Safety Inspection Indicators in Bridges (교량 안전점검 지표별 내하성능 상관관계 분석)

  • Jung, Kyu San;Seo, Dong Woo;Kim, Jae Hwan;Cho, Han Min;Park, Ki Tae;Shin, Yeon-Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.3
    • /
    • pp.89-99
    • /
    • 2022
  • Bridges are a key infrastructure that underpins economic and social activities. In Korea, bridges began to be built with economic development in the 1970s and were built intensively in the 1980s and 1990s. In recent years, as the number of bridges with a service life of more than 30 years is increasing, continuous maintenance is required to ensure the safety of the bridges. In particular, in order to cope with the aging of bridges, research on technology development such as maintenance using ICT technology, preventive maintenance, life cycle cost reduction, and long life bridge is being actively promoted. This paper presents the results of correlation analysis based on the safety evaluation data of bridges as part of the research on the development of a model for estimating load-carrying capacity of bridges. As a analysis result, indicators highly correlated with the load-carrying capacity of the bridge was derived.

Evaluation of Structural Performance of Precast Prestressed Hollow-Core Slabs with Shear Reinforcement (전단철근이 배치된 프리캐스트 프리스트레스트 중공슬래브의 구조성능 평가)

  • Sang-Yoon Kim;Seon-Hoon Kim;Deuck-Hang Lee;Sun-Jin Han;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • This study aims to investigate the structural performance of hollow-core slab (HCS) memebers with 400 mm thickness. To this end, a total of four HCS specimens were fabricated based on the individual mold method to provide shear reinforcement, unlike the extrusion method. The key variables were chosen as the presence of topping concrete, core-filling concrete, and shear reinforcements. The crack patterns and load-displacement responses of the test specimens were analyzed in detail. Test results showed that inclined shear cracking occurred all the specimens, and that the specimen with shear reinforcement on the web of HCS unit had higher strength and ductility than the specimen without shear reinforcement. In particular, shear reinforcements placed on the web of HCS unit effectively resisted not only to vertical shear force but also to horizontal shear force between the interface of HCS unit and topping concrete. In addition, it was discovered that the method in which shear reinforcements are placed on the web of HCS unit is more effective in improving structural performance than core-filling method.

A Evaluation of Fire Behavior According to Member Thickness of Precast Prestressed Hollow Core Slab of Fire Resistance Section (프리캐스트 프리스트레스트 내화단면 중공슬래브의 부재두께에 따른 화재거동평가 )

  • Yoon-Seob Boo;Kyu-Woong Bae;Sang-Min Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • At construction sites, interest in the production of precast materials is increasing due to off-site conditions due to changes in construction site conditions due to increased labor costs and the Act on the Punishment of Serious Accidents. In particular, the precast prestressed hollow slab has a hollow shape in the cross section, so structural performance is secured by reducing weight and controlling deflection through stranded wires. With the application of structural standards, the urgency of securing fire resistance performance is emerging. In this study, a fire-resistance cross section was developed by reducing the concrete filling rate in the cross section and improving the upper and lower flange shapes by optimizing the hollow shape in the cross section of the slab to have the same or better structural performance and economic efficiency compared to the existing hollow slab. The PC hollow slab to which this was applied was subjected to a two-hour fire resistance test using the cross-sectional thickness as a variable, and as a result of the test, fire resistance performance (load bearing capacity, heat shielding property, flame retardance property) was secured. Based on the experimental results, it is determined that fire resistance modeling can be established through numerical analysis simulation, and prediction of fire resistance analysis is possible according to the change of the cross-sectional shape in the future.

A Study on the Determination of Minimum Welding Condition Based on Structural Strength under Launching for Tandem Blocks (선체 블록 진수 시 필요한 최소 용접 구조 강도 평가에 관한 연구)

  • Myung-Su Yi;Joo-Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1267-1273
    • /
    • 2022
  • Although the Korea shipbuilding industry has recently been receiving most of the orders for ships in the world, production processes are being disrupted due to a shortage of manpower at the production site. This is because the workers quit the shipyard as both work and wages were reduced due to the long slump in the shipbuilding industry. The main reason for the increase in orders was the large-scale orders for Qatar LNG carriers, and the situation in which the technical specifications required for ships are becoming more complex is also working to an advantage. Because the contract delivery time is of utmost importance for ships, the dock launch plan is the most important management item among the shipyard's major processes. The structure to be built in the dock may be a hull that has left the design work or a finished vessel, and in some cases, it is often at the level of some blocks of the hull. When launching, the hull is affected by the hogging or sagging moment due to the fluid force, and securing the safety of the structural strength of the block connection is of utmost importance. In a normal process, the connecting member launches after welding has been completed, but in actual shipbuilders, quick decision-making is needed on the conditions for securing structural safety to comply with the docking schedule. In this study, a detailed analysis method and applicability using a bending stress evaluation method and finite element analysis modelling were analyzed to rationally judge the above-mentioned problems from an engineering point of view. The main contents mentioned in the thesis can be used as good examples when conducting similar structural strength evaluations in the future.

Structural Performance of Coated Steel Pipe Connections Subjected to Various Loading Conditions: An Analytical Study (다양한 하중 조건에 따른 코팅 강관 연결부의 구조성능 평가)

  • Myung Kue Lee;Sanghwan Cho;Min Ook Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.4
    • /
    • pp.233-241
    • /
    • 2024
  • In this study, finite element analyses of coated steel pipes were conducted to research the development of sensing-based monitoring smart pipes. The coated steel pipes underwent a chemical coating pretreatment process that used modified polyethylene on both the inside and outside surfaces. Furthermore, the steel pipes were designed to minimize damage during the expansion process by incorporating connecting parts. To evaluate structural performance under various loads, four loading conditions were established: static structural analysis by earth pressure, fatigue life evaluation by vehicle load, and resistance to water leakage under both tensile and compressive loads. The analysis estimated a higher fatigue life for the developed steel pipe, compared with that of a steel pipe using ready-made epoxy coatings and joints. In addition, an average maximum displacement reduction of 56.1% and a maximum stress reduction of 61.2% were confirmed under identical conditions and diameters, thereby verifying the safety of the connecting parts of the developed coated steel pipe. Furthermore, the results of stress distribution contour analyses revealed superior water leakage resistance at the fastening parts, compared with the centers of the pipes.