• Title/Summary/Keyword: structural deterioration

Search Result 603, Processing Time 0.032 seconds

Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details (강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동)

  • Kang, In-Seok;Hur, Moo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.737-744
    • /
    • 2012
  • Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.

Bond deterioration of corroded steel in two different concrete mixes

  • Zhou, Haijun;Liang, Xuebing;Wang, Zeqiang;Zhang, Xiaolin;Xing, Feng
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.725-734
    • /
    • 2017
  • This paper investigated the effects of rebar corrosion on bond performance between rebar and two different concrete mixes (compressive strengths of 20.7 MPa and 44.4 MPa). The specimen was designed as a rebar centrally embedded in a 200 mm concrete cube, with two stirrups around the rebar to supply confinement. An electrochemical accelerated corrosion technique was applied to corrode the rebar. 120 specimens of two different concrete mixes with various reinforcing steel corrosion levels were manufactured. The corrosion crack opening width and length were recorded in detail during and after the corrosion process. Three different loading schemes: monotonic pull-out load, 10 cycles of constant slip loading followed by pull-out and varied slip loading followed by pull-out, were carried out on the specimens. The effects of rebar corrosion with two different concrete mixes on corrosion crack opening, bond strength and corresponding slip value, initial slope of bond-slip curve, residual bond stress, mechanical interaction stress, and energy dissipation, were discussed in detail. The mean value and coefficient of variation of these parameters were also derived. It was found that the coefficient of variation of the parameters of the corroded specimens was larger than those with intact rebar. There is also obvious difference in the two different concrete mixes for the effects of rebar corrosion on bond-slip parameters.

Detection of Iron Phases Presents in Archaeological Artifacts by Raman Spectroscopy

  • Barbosa, A.L.;Jimenez, C.;Mosquera, J.A.
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.60-67
    • /
    • 2018
  • The compounds associated with corrosion, in metallic archaeological samples of carbon steel of insular origin were evaluated to establish their degree of deterioration and structural damage against air pollution. The iron phases present in samples of archaeological artifacts were detected by Raman spectroscopy and confocal Raman microcopy. These samples mainly exhibited ing mainly ${\beta}$-FeO(OH) type goethite oxyhydroxides and small amounts of akaganeite ${\alpha}$-FeO(OH) lepidocrocite ${\gamma}$-FeO(OH) due to dominant chloride in a marine environment and non-stoichiometric oxyhydroxides Fe (II + / III +) as indicators of early corrosion. Some parts showed the presence of magnetic maghemite indicating high corrosion. ${\gamma}$-FeO(OH) is a precursor of phases associated with advanced marine corrosion. By studying its decomposition by Raman spectroscopy, it was synthesized with the following sequence: ${\gamma}-FeO(OH){\rightarrow}{\alpha}-FeO(OH)+{\gamma}-FeO(OH)$, ${\rightarrow}{\gamma}-Fe_2O_3+Fe_3O_4$. Ferric compounds provided evidence for the effect of intensity of laser on them, constituting a very useful input for the characterization of oxidation of iron in this type of artifacts. Thus, destructive analysis techniques should be avoided in addition to the use of small amounts of specimen.

Analysis on Flood Control Effect of Siphon Spillway by Reservoir Routing (저수지 추적을 통한 사이펀 여수로의 홍수조절 효과 분석)

  • Ko, Suhyeon;Kim, Jaeyoung;Lee, Giha
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.55-63
    • /
    • 2013
  • Agricultural small dam reservoirs in Korea are vulnerable to flooding because of insufficient flood control capacity and deterioration such that reservoir water level is likely to rise rapidly and a large amount of water release quickly to downstream without flood warning. In this study, we performed hydrologic analysis to estimate design flood(200 years return period ${\times}1.2$) and also evaluated the effect of siphon spillway as a structural countermeasure for flood control and mitigation by applying reservoir routing to the Jipyeong reservoir, located in Sangju, Korea. The results show that the design flood was calculated at $284.3m^3/s$, and water level and water release decreased by 40cm and $91m^3/s$, respectively.

An Experimental Study on Structural Behaviour of Asymmetric H Beam Slim floor under Load Condition in Fire (내화 피복된 비대칭 H형강을 적용한 슬림플로어 보의 재하가열조건 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Hyung-Jun;Min, Byung-Youl;Lee, Jae-Sung;Park, Soo-Yong
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2011
  • When it comes to slim floor using asymmetric H-beam, it was designed that the steel member is embedded in concrete with relatively low thermal conductivity so as to minimize the deterioration of rigidity of steel member in fire. But given the bottom flange of asymmetric H-beam is directly exposed to the fire, the measure of applying the fireproof coating to improve the fire rate performance of slim floor beam was sought. The test was aimed at comparing the fireproof performance by adjusting the load ratio of 0.4 and 0.3, and The test was carried out to identify the 3-hour fire performance by reinforcing the beam as well as applying the fireproof coat, In the wake of comparing the specimen depending on variation of load ratio, lowering load ratio by 0.1 resulted in difference of 12 minutes and deflection was 39 mm. It was able to improve 12 minutes by reinforcing the beam and up to 102.4 mm in deflection.

Spectral Energy Transmission Method for Crack Depth Estimation in Concrete Structures (콘크리트 구조물의 균열 깊이 추정을 위한 스펙트럼 에너지 기법)

  • Shin, Sung-Woo;Min, Ji-Young;Yun, Chung-Bang;Popovics, John S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.164-172
    • /
    • 2007
  • Surface cracks in concrete are common defects that can cause significant deterioration and failure of concrete structures. Therefore, the early detection, assessment, and repair of the cracks in concrete are very important for the structural health. Among studies for crack depth assessment, self-calibrating surface wave transmission method seems to be a promising nondestructive technique, though it is still difficult in determination of the crack depth due to the variation of the experimentally obtained transmission functions. In this paper, the spectral energy transmission method is proposed for the crack depth estimation in concrete structures. To verify this method, an experimental study was carried out on a concrete slab with various surface-opening crack depths. Finally, effectiveness of the proposed method is validated by comparing the conventional time-of-flight and cutting frequency based methods. The results show an excellent potential as a practical and reliable in-situ nondestructive method for the crack depth estimation in concrete structures.

Deterioration State and Behavior of Discontinuity System of the Seosan Maaesamjonbulsang (Rock-carved Triad Buddha in Seosan), Korea (서산 마애삼존불상의 훼손상태 및 불연속면의 거동특성)

  • Lee, Sun-Myung;Lee, Chan-Hee;Choi, Seok-Won;Yun, Seok-Bong
    • Journal of Conservation Science
    • /
    • v.19
    • /
    • pp.85-98
    • /
    • 2006
  • Rock property of the Seosan Maaesamjonbulsang is composed of biotite granite with medium grained texture. The triad Buddha is highly deteriorated by the joint, fracture, break-out, exfoliation, dew condensation of the surface and discoloration of the secondary pollutant. Host rock of the triad Buddha is divided dozens of rock blocks with various shape, and developed irregular discontinuity planes. Besides, the host rock is promoted biological pollution due to the surrounding crowded vegetation and high humidity environment. As the results of structural stability, it is confirmed that developed discontinuity system in the host rock is exposed instability sloping environment. Therefore, the host rock and surroundings are required maintenance, and required preservation by continuance monitoring for understand behavior of discontinuity system.

  • PDF

Survey for the Management of Reservoirs under Control of Local Authorities of Reservoir of City.Gun in Korea (시.군 관리 저수지 실태 조사 및 정비방안에 관한 연구)

  • Choi, Won;Kim, Han-Jung;Yoon, Seong-Su;Kim, Jong-Ok;Jung, Nam-Su;Lee, Hyung-Jin;Han, Yi-Cheol;Lee, Jeong-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.3
    • /
    • pp.31-41
    • /
    • 2008
  • There are many agricultural facilities (46.7%) that have been over 30 years in the Republic of Korea (the ratio of reservoirs built before 1945 is 53%, from 1946 to 1971 is 35%). In the case of reservoirs which do most important functions among these facilities, only 3,000 reservoirs are managed by Korea Rural Community & Agriculture Corporation (KRC) and the other 15,000 reservoirs are managed by local authorities (City and Gun). But, 15,000 reservoirs included in City. Gun have been built in more wide area than KRC and the reservoir management system has not been operated well because of shortage of budget and manpower of the local authorities. Particularly, the abnormal weather happened during every summer season recently has ruined a lot of rural community facilities. So flood control function have been more important than irrigation function in agricultural reservoir system and it may be required to introduce new safe, management and maintenance techniques in City Gun reservoirs. So we investigated landscapes and deteriorations of agricultural reservoirs managed by local small governments for revealing not only present usage but also future value. Survey shows that there are no structural managements except typical hydrological reportings and the deterioration of small darn is very serious. There are needs for more systematic management system and equipment methods. Therefore, this study may suggest that reservoir (that takes charge of the greatest deal of weight in all agricultural facilities) must be considered as new concept of the usage and the unification. On the other hand, reservoir must be also developed as amenity resources, natural circumstances and district values.

Blast Design for Explosive Demolition of Concrete Foundation (기초콘크리트 구조물의 발파해체를 위한 발파설계)

  • Park, Hoon;Park, Hyoung-Ki;Suk, Chul-Gi;Yi, Young-Seop;Kaneko, Katsuhiko
    • Explosives and Blasting
    • /
    • v.30 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • With the deterioration and functional loss of structures, there is an increasing demand for demolition and various demolition technologies have been developed. In case of a large-scale concrete foundation, application of some mechanical demolition techniques is limited because of the structural characteristics, and explosive demolition or explosive demolition combined with mechanical demolition is applied recently due to the effect to the surrounding environment by the ground vibration. In this study, we compared peak particle velocity of ground vibration depending on average fragment size in case of explosive demolition design for large-scale concrete foundation using the relation among specific charge, charge constant and transmitting medium constant as well as the relation between average concrete fragment size and specific charge.

Performance Evaluation Systems in Water Distribution Network (상수관망의 성능평가를 위한 진단체계 구축)

  • Kim, Ju-Hwan;Kim, Jung-Hyun;Lee, Doo-Jin;Woo, Hyung-Min;Bae, Cheol-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.864-868
    • /
    • 2008
  • Water transmission and distribution systems play a important role to deliver safe and clean water and are responsible for the most direct impacts of water utilities to customers. Although the performance of WDS(Water Distribution Systems) should be evaluated by a certain standards, interests has not been in WDS and developed due to invisible, hard-working and insufficient information in the evaluation process in Korea till now. The investigations and researches were carried out to develop software to assist the evaluation of WDS with respects to hydraulics, water quality and structural analysis methods. The methodologies have been developed which can be used to estimate the performance to water distribution network and software are implemented by the process. Developed systems are consisted with database, analysis techniques, simulation models, decision support systems and other tools. The concepts and functions are introduced in this paper and the performance index are discussed for accurate assessment of water distribution systems.

  • PDF