• Title/Summary/Keyword: stray current

Search Result 112, Processing Time 0.027 seconds

Adaptive Synchronous Rectification Control Method for High Efficiency Resonant Converter

  • Kim, Joohoon;Moon, Sangcheol;Kim, Jintae
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.40-41
    • /
    • 2017
  • New adaptive SR (synchronous rectification) control method is proposed offering high efficiency in entire load conditions for resonant converters, in this paper. Unlike the conventional SR control method where turn-on time of the MOSFETs is varied depending on load conditions due to the stray inductance induced by a lead frame of MOSFET or PCB patterns, the proposed method automatically maintains a time interval between turn-off instance of a MOSFET and zero current instance of a body diode of the MOSFET as a predetermined time, in each switching cycle. Therefore, optimized turn-on time of the MOSFET can be achieved regardless of the leakage inductance. In this paper, the operational principle of proposed control method has been discussed. It has been tested on LLC resonant converter with 240 W to verify the proposed control method.

  • PDF

Modeling and Compensation of Voltage Source Inverter Nonlinearity (인버터 전압왜곡 보상방법의 분석 및 적용상의 문제점에 대한 연구)

  • Kim, Nam-Su;Kim, Hyun-Bae;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1352-1354
    • /
    • 2005
  • In this paper, an improved dead time compensation method which is concerned about dead time and extra time in Pulse-Width-Modulation(PWM) period is presented comparing the existing dead time compensation. The voltage drop across the switches are modeled excluding effect of stray capacitor. A low pass filter(LPF) is adopted for accurate detecting of current polarity. The method is based on Space-Vector-Pulse-Width-Modulation(SVPWM). All simulation results are presented using MATLAB and Simulink.

  • PDF

Balance Winding Scheme to Reduce Common-Mode Noise in Flyback Transformers

  • Fu, Kaining;Chen, Wei
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.296-306
    • /
    • 2019
  • The flyback topology is being widely used in power adapters. The coupling capacitance between primary and secondary windings of a flyback transformer is the main path for common-mode (CM) noise conduction. A Y-cap is usually used to effectively suppress EMI noise. However, this results in problems in space, cost, and the danger of safety leakage current. In this paper, the CM noise behaviors due to the electric field coupling of the transformer windings in a flyback adapter with synchronous rectification are analyzed. Then a scheme with balance winding is proposed to reduce the CM noise with a transformer winding design that eliminates the Y-cap. The planar transformer has advantages in terms of its low profile, good heat dissipation and good stray parameter consistency. Based on the proposed scheme, with the help of a full-wave simulation tool, the key parameter influences of the transformer PCB winding design on CM noise are further analyzed. Finally, a PCB transformer for an 18W adapter is designed and tested to verify the effectiveness of the balance winding scheme.

Recent Progress in Magneto-Mechano-Electric Generators (자기-기계-전기 변환소자를 이용한 에너지 하베스팅 기술)

  • Hwang, Geon-Tae;Ryu, Jungho;Yoon, Woon-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.271-282
    • /
    • 2021
  • The internet of things (IoT) technology is a key component for the advent of 4th industrial revolution, which is the network of home appliances, infrastructures, and vehicles to remotely investigate these systems. For the operation of compact IoT devices, batteries are widely used as electric power, and the limited lifetime of batteries inevitably leads to periodic replacement. Magneto-mechano-electric (MME) generators may be alternatives to batteries inside the IoT devices by converting stray magnetic field into electric energy, since we are always surrounded by ambient alternating current (AC) magnetic fields induced from electric power transmission lines everywhere. This article reviews the recent domestic research progress in high-performance MME generators and their application field for IoT and electronic devices.

Measurement using Low-temperature Scanning Hall Probe Microscopy and Analysis of Local Current Distribution using Inversion Problem Technique (저온 주사 홀소자 현미경과 역변환 방법을 이용한 국소적 전류 분포 분석)

  • Cho, B.R.;Park, S.K.;Park, H.Y.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2011
  • We have performed measurements of the local magnetic field distribution of YBCO coated conductors using Low-temperature Scanning Hall Probe Microscopy (LT-SHPM). Distribution of stray magnetic field of various types of YBCO coated conductors in the superconducting state was measured in presence of external magnetic fields. We analyzed one dimensional and two dimensional local current distribution using inversion technique from the magnetic field distribution.

Effects of Rectifier and Copper Grid Interference on the Detection Reliability of Coating Flaws on Buried Pipes (매설 배관 피복 결함 탐상 정확도에 미치는 인접 정류기 및 접지 구리망 간섭의 영향)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.211-223
    • /
    • 2020
  • The external corrosion of buried piping can be controlled using both coating and cathodic protection. Several factors are involved in the damage and deterioration of the coating on pipes. There are many detection methods for coating defects on pipes and the direct current voltage gradient (DCVG) method is one of the most powerful methods. However, the detection reliability of DCVG can be affected by interferences such as stray current, metal objects connected to rectifiers, and copper grids. Therefore, this study focused on the interference effects of rectifiers and a copper grid on the reliability of coating flaw detection. As the length of the interference pipe connected to the rectifier increased, the reliability decreased. In contrast, as the distance between the pipe and the copper grid increased, the reliability of the coating flaw detection increased. The detection results produced by the DCVG method were discussed using current and potential simulations for a pipe with a rectifier and copper grid interference in the soil.

An Experimental Study on the Improvement of City Gas Buried Double Piping Integrity (도시가스 매설이중배관 건전성 향상에 관한 실험적 연구)

  • Lim, Hyung-Duk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.757-763
    • /
    • 2020
  • City gas buried pipes are managed by corrosion protection to prevent corrosion. In the case of the press-in section, the double pipe and the main pipe may cause corrosion under the influence of stray current, which can shorten the life of the pipes. In addition, if the insulator is filled in the press-in section, the press-in section itself is a single structure, and can be directly affected by external impact, and when the surrounding ground subsidence occurs, the stress may be concentrated, resulting in serious consequences. In this study, a serration-type shock absorber in the form of a sliding support was proposed as a new buried double piping construction method using EPS. The serration-type shock absorber can contribute to the improvement of the integrity of the buried double piping, as it can utilize the gas piping's own ductility and stress distribution characteristics with proper anti-corrosion management and shock-absorbing material properties by preventing contact inside the buried double pipe. However, for application to ground piping, there remains a task to supplement the vulnerability against fire due to the characteristics of EPS materials.

A Study of the Autonomous Vehicle Technology and its Future Trend : Focusing on Current Industry and Technology Convergence of Trend (자율주행 기술의 현황과 미래 동향 고찰 : 산업계 동향을 중심으로 기술 융합 관점의 접근)

  • Park, Seongkeun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.253-259
    • /
    • 2018
  • The Korea Convergence Society. Recently, as the 4th industrial revolution is rising, there are many changes in various field of industries. Among these industries, autonomous vehicles based on artificial intelligence, big data and internet of things is one of the most promising industry. Autonomous vehicle stray from classical car domain of manufacturers and suppliers, IT/Electronics suppliers and communication companies are widen their business area to autonomous vehicle technology. In this paper, we analysis the state of art of autonomous vehicle technology and development direction of industries/research institute. Finally, we discuss the social/economic effects of autonomous vehicle.

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

Properties and Applications of Magnetic Tunnel Junctions

  • Reiss, G.;Bruckl, H.;Thomas, A.;Justus, M.;Meyners, D.;Koop, H.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.24-31
    • /
    • 2003
  • The discoveries of antiferromagnetic coupling in Fe/Cr multilayers by Grunberg, the Giant Magneto Resistance by Fert and Grunberg and a large tunneling magnetoresistance at room temperature by Moodera have triggered enormous research on magnetic thin films and magnetoelectronic devices. Large opportunities are especially opened by the spin dependent tunneling resistance, where a strong dependence of the tunneling current on an external magnetic field can be found. We will briefly address important basic properties of these junctions like thermal, magnetic and dielectric stability and discuss scaling issues down to junction sizes below 0.01 $\mu\textrm{m}$$^2$with respect to single domain behavior, switching properties and edge coupling effects. The second part will give an overview on applications beyond the use of the tunneling elements as storage cells in MRAMs. This concerns mainly field programmable logic circuits, where we demonstrate the clocked operation of a programmed AND gate. The second 'unconventional' feature is the use as sensing elements in DNA or protein biochips, where molecules marked magnetically with commercial beads can be detected via the dipole stray field in a highly sensitive and relatively simple way.