• Title/Summary/Keyword: still-motion

Search Result 369, Processing Time 0.025 seconds

Vision-Based Dynamic Motion Measurement of a Floating Structure Using Multiple Targets under Wave Loadings (다중 표적을 이용한 부유식 구조물의 영상 기반 동적 응답 계측)

  • Yi, Jin-Hak;Kim, Jin-Ha;Jeong, Weon-Mu;Chae, Jang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.19-30
    • /
    • 2012
  • Recently, vision-based dynamic deflection measurement techniques have significant interests and are getting more popular owing to development of the high-quality and low-price camcorder and also image processing algorithm. However, there are still several research issues to be improved including the self-vibration of vision device, i.e. camcorder, and the image processing algorithm in device aspect, and also the application area should be extended to measure three dimensional movement of floating structures in application aspect. In this study, vision-based dynamic motion measurement technique using multiple targets is proposed to measure three dimensional dynamic motion of floating structures. And also a new scheme to select threshold value to discriminate the background from the raw image containing targets. The proposed method is applied to measure the dynamic motion of large concrete floating quay in open sea area under several wave conditions, and the results are compared with the measurement results from conventional RTK-GPS(Real Time Kinematics-Global Positioning System) and MRU(Motion Reference Unit).

Comparative Study on the Interface and Interaction for Manipulating 3D Virtual Objects in a Virtual Reality Environment (가상현실 환경에서 3D 가상객체 조작을 위한 인터페이스와 인터랙션 비교 연구)

  • Park, Kyeong-Beom;Lee, Jae Yeol
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Recently immersive virtual reality (VR) becomes popular due to the advanced development of I/O interfaces and related SWs for effectively constructing VR environments. In particular, natural and intuitive manipulation of 3D virtual objects is still considered as one of the most important user interaction issues. This paper presents a comparative study on the manipulation and interaction of 3D virtual objects using different interfaces and interactions in three VR environments. The comparative study includes both quantitative and qualitative aspects. Three different experimental setups are 1) typical desktop-based VR using mouse and keyboard, 2) hand gesture-supported desktop VR using a Leap Motion sensor, and 3) immersive VR by wearing an HMD with hand gesture interaction using a Leap Motion sensor. In the desktop VR with hand gestures, the Leap Motion sensor is put on the desk. On the other hand, in the immersive VR, the sensor is mounted on the HMD so that the user can manipulate virtual objects in the front of the HMD. For the quantitative analysis, a task completion time and success rate were measured. Experimental tasks require complex 3D transformation such as simultaneous 3D translation and 3D rotation. For the qualitative analysis, various factors relating to user experience such as ease of use, natural interaction, and stressfulness were evaluated. The qualitative and quantitative analyses show that the immersive VR with the natural hand gesture provides more intuitive and natural interactions, supports fast and effective performance on task completion, but causes stressful condition.

Study on Characteristics of ECG Electrodes for Motion Artifact Reduction (동잡음 저감을 위한 심전도 전극 특성에 대한 연구)

  • Kang, Young-Hwan;Park, Jae-Soon;Cho, Bum-Ki;Choi, Sang-Dong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

The Clinical Results of Conservative Treatment of Frozen Shoulder Using Continuous Passive Motion

  • Chung, Hoe-Jeong;Kim, Doo-Sup;Yoon, Yeo-Seung;Lee, Dong-Woo;Hong, Kyung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.217-220
    • /
    • 2015
  • Background: The purpose of this study is to administer conservative treatment in 30 patients diagnosed with idiopathic frozen shoulder, following the suggested frozen shoulder rehabilitation program and to assess the clinical outcome using a prospective study. Methods: Thirty patients diagnosed with idiopathic frozen shoulder, treated with steroid hormone injection on the articular joint with an intra-articular steroid (triamcinolone 40 mg+lidocaine 4 ml) injection and started on stepwise shoulder extension exercise were chosen. The subjects were divided into two groups of 15 people each with one group undergoing rehabilitation with continuous passive motion (CPM) and the other group without it. Follow-ups were done before rehabilitation and at 4-week intervals with the 24th being the final week. At every follow-up, passive range of motion (ROM) was measured and surveys on pain and clinical score were administered. Results: In the last follow-up, both groups showed statistically significant improvements in all evaluation criteria. However, no statistical difference in all values of the ROM and Constant score evaluation criteria was observed between the groups. Only in the last follow-up, group 1 had a visual analog scale (VAS) score of $2.4{\pm}2.1$ points, which was lower, with statistical significance, than the VAS score of group 2, which was $4.4{\pm}3.1$ points (p<0.001). Conclusions: Study using CPM in treatment of frozen shoulder has been inadequate, meaning that there is still room for improvement and need for more study on setting a more specific protocol and guidelines for this procedure.

Unusual Behavior Detection of Korean Cows using Motion Vector and SVDD in Video Surveillance System (움직임 벡터와 SVDD를 이용한 영상 감시 시스템에서 한우의 특이 행동 탐지)

  • Oh, Seunggeun;Park, Daihee;Chang, Honghee;Chung, Yongwha
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.11
    • /
    • pp.795-800
    • /
    • 2013
  • Early detection of oestrus in Korean cows is one of the important issues in maximizing the economic benefit. Although various methods have been proposed, we still need to improve the performance of the oestrus detection system. In this paper, we propose a video surveillance system which can detect unusual behavior of multiple cows including the mounting activity. The unusual behavior detection is to detect the dangerous or abnormal situations of cows in video coming in real time from a surveillance camera promptly and correctly. The prototype system for unusual behavior detection gets an input video from a fixed location camera, and uses the motion vector to represent the motion information of cows in video, and finally selects a SVDD (one of the most well-known types of one-class SVM) as a detector by reinterpreting the unusual behavior into an one class decision problem from the practical points of view. The experimental results with the videos obtained from a farm located in Jinju illustrate the efficiency of the proposed method.

Biomechanical Effects of Posterior Dynamic Stabilization System on Lumbar Kinematics: A Finite Element Analysis (Posterior Dynamic Stabilization System의 요추거동에 대한 생체역학적 분석)

  • Ahn, Y.H.;Chen, Wen-Ming;Jung, D.Y.;Park, K.W.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.139-145
    • /
    • 2008
  • Many recent studies suggest that the posterior dynamic stabilization(PDS) can be a more physiologically-relevant alternative to the rigid fixation for the patients suffering from low back pain. However, its biomechanical effects or clinically proven efficacies still remain unknown. In this study, we evaluated kinematic behaviors of the lower lumbar spine with the PDS system and then compared to those of the rigid fixation system using finite element (FE) analysis. A validated FE model of intact lumbar spine(L2-L5) was developed. The implanted model was then constructed after modification from the intact to simulate two kinds of pedicle screw systems (PDS and the rigid fixation). Hybrid protocol was used to flex, extend, laterally bend and axially rotate the FE model. Results showed that the PDS systems are more flexible than rigid fixation systems, yet not flexible enough to preserve motion. PDS system allowed $16.2{\sim}42.2%$ more intersegmental rotation than the rigid fixation at the implanted level. One the other hand, at the adjacent level it allowed more range of motion ($2.0%{\sim}8.3%$) than the rigid fixation. The center of rotation of the PDS model remained closer to that of the intact spine. These results suggest that the PDS system could be able to prevent excessive motion at the adjacent levels and restore the spinal kinematics.

Studies on Garment Restraint (IV) -Effect of Slacks Restraint on Lower Extremity- (의복의 구속성에 관한 연구 (IV) -슬랙스 착용시의 하지부 압박을 중심으로-)

  • 심부자;최선희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.387-394
    • /
    • 1994
  • Journal of the Korean Society of Clothing and Textiles Vol. 18, No. 3 (1994) p. 387∼394 In this study, the restriction of slacks (blue jean) versus box pleats skirt was investigated, from the view point of peripheral blood flow at the toe according to motion variation and E.M.G. analysis of leg muscles after walking on the flat or going up and down stairways. Besides, the pressure of slacks on the lower extrimity was measured statically and dynamically. The main results were summerized as follows; 1. The clothing pressure applied by slacks was; each one of thigh and lower leg was 18.2 g/ cm2 and 22.1 g/cm2 in upright, 63.4 g/cm2 and 26.6 g/cm2 in sitting on the chair, on both sides of thigh and lower leg 272.0 g/cm2 over in squatting. 2. When the motion starts from upright, the dynamic clothing pressure reach their peak before the motions end. When the motion ends and the body comes to a still condition, the clothing pressure grow lower and indicate a constant value. but when the body starts moving again to return to upright, the pressures once grow higher and go to zero value after reaching the peak. The pressure on the knee show much greater than those on the hip. This can be because these pressures depend on the degree of skin stretching motion and of its curvature. 3. The surface E.M.G. in leg muscles M. rectus femoris and M. gastrocnemius were recoreded. In the case of wearing slacks, two muscles were activated much more than wearing skirt. 4. The peripheral blood flow at the toe by wearing slacks was lower than wearing skirt. Also the case when squatting, the peripheral blood flow at the toe was low.

  • PDF

3D motion aftereffect in a static region after adaptation to an adjacent counterphase flickering region (역 위상 깜박임 영역 순응에 의해 유도된 인접 영역의 3차원 운동잔여 효과)

  • 김정훈;남종호;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.10 no.3
    • /
    • pp.29-37
    • /
    • 1999
  • Murakami and Cavanagh (1998a,b, 1999) reported a jitter aftereffect in a static random noise after a period of adaptation to a patch of dynamic random noise. To a account for this phenomenon. they proposed the retinal slip caused by a small eye movements in the unadapted area, which is usually compensated by the visual system to stabilize images but is unsuppressed due to the adaptation. We tested this hypothesis with new experimental method and stimuli that were supposed to nullify or reduce the effect. However. the aftereffect was still observed even under these stimuls conditions More importantly, the perceived aftereffect was rather different from Murakami and Cavanagh's. After adaptation to a counterphase flickering cosine grating, the adjacent unadapted region seems to move away from the observer during the test period instead of jittering in the frontoparallel plane. We proposed a possible explanation for this new phenomenon noting the severe contrast reduction of the adapted region during flickering period. The aftereffect might be due to the flicker-inducing contrast reduction during adaptation that produces different depth planes for the adapted and unadapted region and its restoration during the test period.

  • PDF

Analysis of the cause of VIMS for minimizing VR nausea in VR environment (VR 환경에서의 사이버 멀미 최소화를 위한 어지럼증 유발 원인 분석)

  • Lee, Jae-Gap;Shin, Jeong-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.133-138
    • /
    • 2018
  • VR technology is a technology that allows a user to experience virtual reality close to reality by wearing an HMD (Head Mounted Display) device. Recently, as the interest in VR technology increases due to the 4th industrial revolution, various HMD devices are spreading. As a result, VR technology is being rapidly applied to various fields, but many of them still experience VR nausea. VR nausea is caused mainly by visual factors, unlike motion nausea, such as car nausea, sea nausea, and air nausea. Such occurrence of VR nausea may be caused by the characteristics of visual information of VR video contents, the hardware characteristics of HMD devices blocking the external visual field, or the physical specificity of individuals, and it is difficult to distinguish the causes. In this paper, we aim to analyze the characteristics of Visually Induced Motion Nausea images focusing on VR video content, which is the cause of VR nausea, in order to search for minimization of Cyber sickness occurrence.

Early and Delayed Postoperative Rehabilitation after Arthroscopic Rotator Cuff Repair: A Comparative Study of Clinical Outcomes

  • Choi, Sungwook;Seo, Kyu Bum;Shim, Seungjae;Shin, Ju Yeon;Kang, Hyunseong
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.4
    • /
    • pp.190-194
    • /
    • 2019
  • Background: The duration of immobilization after arthroscopic rotator cuff repair and the optimal time to commence rehabilitation are still the subject of ongoing debates. This study was undertaken to evaluate the functional outcome and rotator cuff healing status after arthroscopic rotator cuff repair by comparing early and delayed rehabilitation. Methods: Totally, 76 patients with small, medium, and large sized rotator cuff tears underwent arthroscopic repair using the suturebridge technique. In early rehabilitation group, 38 patients commenced passive range of motion at postoperative day 2 whereas 38 patients assigned to the delayed rehabilitation group commenced passive range of motion at postoperative week 3. At the end of the study period, clinical and functional evaluations (Constant score, the University of California, Los Angeles [UCLA] shoulder score) were carried out, subsequent to measuring the range of motion, visual analogue scale for pain, and isokinetic dynamometer test. Rotator cuff healing was confirmed by magnetic resonance imaging at least 6 months after surgery. Results: No significant difference was obtained in range of motion and visual analogue scale between both groups. Functional outcomes showed similar improvements in the Constant score (early: 67.0-88.0; delayed: 66.9-91.0; p<0.001) and the UCLA shoulder score (early: 20.3-32.3; delayed: 20.4-32.4; p<0.001). Furthermore, rotator cuff healing showed no significant differences between the groups (range, 6-15 months; average, 10.4 months). Conclusions: Delayed passive rehabilitation does not bring about superior outcomes. Therefore, early rehabilitation would be useful to help patients resume their daily lives.