• 제목/요약/키워드: sterilize

검색결과 92건 처리시간 0.026초

이동형 UV 공간 살균 기기의 안전성 확보 방안에 관한 연구 (A Study on Ensuring the Safety of Potable UV Space Germicidal Equipment)

  • 정한석;김충혁;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.94-100
    • /
    • 2024
  • Recently, as interest in personal hygiene has increased due to the community spread of COVID-19 and variant viruses, fixed and potable UV germicidal equipment to sterilize indoor spaces and hand-held UV germicidal equipment to sterilize household items such as masks and mobile phones are continuously being developed and sold. However, the development and sales of the product are difficult because appropriate testing methods have not yet been established. In this situation, if an uncertified product is distributed in the market, it can cause serious harm to consumers. In this study, we investigate the photobiological risks and safety devices against UV exposure of UV germicidal equipment distributed domestically, and propose appropriate test methods for portable UV germicidal equipment based on the research results.

전폐절제술후 27년 6개월에 발생한 농흉 치험 -1례 보고- (Postpneumonectomy Empyema That Occurred 27 1/2 Years After Initial Pneumonectomy -A Case Report-)

  • 이광선
    • Journal of Chest Surgery
    • /
    • 제28권5호
    • /
    • pp.504-506
    • /
    • 1995
  • Postpneumonectomy empyema is an infrequent but dreaded complication. The seriousness of this complication is impossible to eliminate the space containing the infection, and consequently, it is difficult to sterilize the space. The time from pneumonectomy to the development of an empyema ranges from several days to several years, with most evident with 4 weeks. We experienced a case of postpneumonectomy empyema that occurred 27 1/2 years after initial pneumonectomy. She was treated with intrapleural antiseptic irrigation and open-tube drainage following partial decortication. The patient had an uneventful recovery and was discharged from hospital with improved condition.

  • PDF

오존발생기의 기술동향 및 전망 (The Technical Trend and Prospect of Ozonizer)

  • 조국희;김영배;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 2001
  • Ozone is widely used to sterilize food and tap water because ozone is a strong oxidizer. Efficient ozone generation is the most important issue in the field of ozone application. A variable discharge type of ozonizer that generates diffuse glow discharge in air at atmospheric pressure was used for the efficient ozone generation.

  • PDF

Acute Postpneumonectomy Empyema with Bronchopleural Fistula Treated with Vacuum-assisted Closure Device

  • Han, Woo-Sik;Kim, Kwhan-Mien
    • Journal of Chest Surgery
    • /
    • 제45권4호
    • /
    • pp.260-262
    • /
    • 2012
  • Postpneumonectomy empyema is a life-threatening complication, which is often related with a bronchopleural fistula. After surgical repair of fistula, sterilization of infected pleural cavity is important and usually carried out by long-term cyclic irrigation. We report a case in which vacuum-assisted closure device was successfully applied to sterilize the pleural cavity and obliterate bronchopleural fistula.

중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태 (Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China)

  • 정효하;문혜경
    • 급식외식위생학회지
    • /
    • 제2권2호
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

고전압 펄스에 의한 전기 살균에서 방전 파형의 특성 분석 (Discharge Waveform Properties on Electrical Sterilization by HV Impulse)

  • 이희규;말광순야;원아칙;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.944-946
    • /
    • 1998
  • We evaluated cell survivability by changing RLC value on HV impulse network. When the L value is changed from 0 to 10mH in this circuit. we found that cell survivability is shown large decline with 4mH of L value. I respect to this result, when waveshapes of oscillatory decay are presented along the variation of L value in RLC circuit, we analyzed whether discharge waveform properties have an effect on sterilization ratio, and measured threshold voltage as the minimum peak voltage of a single pulse which can sterilize cells. Finally, we found that the sterilization effect was related to number of threshold voltage waveforms being applied.

  • PDF

병원감염 예방을 위한 Film Cassette의 자외선 소독 효과 (Disinfection Efficacy of an Ultraviolet Light on Film Cassettes for Preventive of the Nosocomial Infection)

  • 권대철;전용웅;조암
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.27-32
    • /
    • 2001
  • The bacteria infection on film cassette contact surface was examined at the diagnostic radiology department of the S. hospital. The objective of this study was to assess the contamination level on film cassette contact surface as a predictor of patient prevention from nosocomial infection and for improvement of the hospital environment. The laboratory result was identified non-pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection is proven suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In addition education of nosocomial infection for radiographers will be required. In conclusion, ultraviolet is considered effective to irradate bacteria. Additionally, two minutes are required to sterilize film cassettes.

  • PDF

의약품 제조시설의 포름알데히드가스 훈증살균과 최근 실내무균화방법의 동향

  • 한국공기청정협회
    • 공기청정기술
    • /
    • 제23권3호
    • /
    • pp.34-43
    • /
    • 2010
  • In most productive facility of pharmaceutical companies, the fumigation using formaldehyde gas has been put into operation. Because formaldehyde gas is so bactericidal as to sterilize bacterial spore which can not be sterilized with usual disinfectants, it has been used for fumigation in many facilities such as facility of experimental animals, research institute and productive facility of pharmaceutical companies which are required to be high level of biological clean. However, the use of formaldehyde is recently under the strict management because of its causing of sick house and carcinogenesis. We introduce the conditions of sterilization using formaldehyde gas, the examples of sterilization using formaldehyde gas in a pharmaceutical manufacture and the problems of use of formaldehyde against environments and health. Further, we describe the characteristics and future subjects of the sterilization method using gasified oxidants such as hydrogen peroxide, peracetic acid and chlorine oxide.

  • PDF

마이크로파를 이용한 물 살균장치에 관한 연구 (A Study on the Water Sterilizer using the Microwave)

  • 이창호;이화용
    • 대한전자공학회논문지TC
    • /
    • 제41권8호
    • /
    • pp.113-117
    • /
    • 2004
  • 본 논문은 마이크로파를 이용하여 물 살균특성을 실험 조사하기 위해 마이크로파 살균장치를 설계 제작하고, 특성을 실험 한 결과 매우 양호한 효과를 얻었다. 특히 세균 함유량이 많은 하천수를 마이크로파로 10초, 20초, 30초, 40초, 50초, 60초 살균시켜 수질 검사기관에 수차례 검사를 의뢰한 결과 살균한 물의 대장균수와 일반 세균수가 살균 시간에 따라 급격히 감소하는 것을 알 수 있었다.

Gamma선 조사에 의한 의류제품의 멸균연구 (A Study on Sterilization of Medical Products by Gamma-irradiation.)

  • 정해원;정문식;문석형
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF