• Title/Summary/Keyword: steel specimen

Search Result 1,904, Processing Time 0.029 seconds

Prefabricated-HSPRCC panels for retrofitting of existing RC members-a pioneering study

  • Bedirhanoglu, Idris
    • Structural Engineering and Mechanics
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 2015
  • The main goal of this study was to develop a convenient strengthening technique for retrofitting of reinforced concrete members. For this purpose a new retrofitting material so-called prefabricated-HSPRCC (high performance steel plate reinforced cementitious composite) panel was developed by using high performance concrete and perforated steel plate. Prefabricated-HSPRCC composes advantages of steel and high performance concrete. The prefabricated-HSPRCC panels were either only bonded on the specimens using epoxy mortar or anchored to the specimen by steel bolts as well as bonding. Effect of different variations such as prefabricated-HSPRCC panel thicknesses, steel plate thicknesses, puncture orientation of perforated steel plate, existence of anchorage etc. were studied through a simple experimental work. The behaviour of the specimens under vertical point load was also studied by using simple mechanics. The retrofitted specimens were found to exhibit much better performance both in terms of strength and deformation capability. The anchorage application was found to positively affect this improved performance. Furthermore, as a result of the tests the best parameters of prefabricated-HSPRCC plate for improving strength and deformation capacities were determined.

Crack and Deformation Behaviors of Steel Fiber Reinforced Concrete Slab Model Specimens Using Domestic Steel Fiber (국내 강섬유를 사용한 강섬유보강 콘크리트 슬래브 모델의 균열 및 변형특성)

  • 박승범;홍석주;이봉춘;조춘근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.319-324
    • /
    • 1999
  • This study is to investigate the properties on the load-deflection and fracture behaviors of the steel fiber reinforced concrete(SFRC) slab model specimens, Steel fibers of indent, crimp, and end hook shape were considered to reinforce the matrix under various mixing conditions and proportions. Initial cracking load, maximum load, and energy absorption capacity(load carrying capacity) of SFRC panel specimen increased with increase of steel fiber contents. And the plain concrete slab was fractured abruptly after maximum load but SRFC slabs were fractured smoothly by steel fibers in concrete matrix operated as cracking resistance force after maximum load. Indent, crimp and end hook shape steel fibers were effective in reinforcing the matrices but end hook type fiber were superior to indent and crimp type fibers.

  • PDF

A Study on the Bond Strength of Coated Rebar in Concrete (콘크리트중 코팅철근의 부착응력에 대한 기초적 연구)

  • 문한영;김성수;류재석;김성섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.127-132
    • /
    • 1996
  • Recently in the country a corrosion of steel is accelerated due to using of sea sand including salts, and critical problem on the durability of concrete structure is occured. Thus a control of steel corrosion is very important in the stability of structure. Coated steel is in use with a method of steps of steel corrosion in U.S,A. Japan etc, and as well in domestic case the manufactured coating steel of three types is on the market. Those are Epoxy coated steel, Zinc-strength, concrete specimen size, bar diameter, which can affect bond characteristics between steel and concrete in order to know their relative bond characteristics.

  • PDF

Cavitation-erosion Resistance of Stabilized Stainless Steel with Niobium Addition in Sea Water Environment (해수 내 캐비테이션-침식 저항성에 미치는 스테인리스강의 Nb 첨가의 영향)

  • Choi, Yong-Won;Han, Min-Su;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.274-279
    • /
    • 2016
  • Stainless steel is widely used in various industries due to its excellent anti-corrosion characteristics. However, if the stainless steel is exposed to high speed fluid flow and chloride ion in the marine environment, corrosion and cavitation damage occurred on the surface easily. Therefore, to prevent these problems, stabilzed stainless steel is applied to offshore and shipbuilding industries. In this study, stabilized stainless steel specimen was made by 19%Cr-9%Ni with different Nb contents (0.29%, 0.46% and 0.71%). And then, their cavitation characteristics were investigated. As a result, the characteristics of cavitation resistance of stainless steel could be improved by increasing Nb contents.

The Characteristics of the Hydrogen Embrittlement for the Cr-Mo Steels in Use of Pressure Vessel (압력용기용 Cr-Mo강의 수소취화 특성)

  • Lee, Hwi-Won;Yang, Hyun-Tae;Kim, Sang-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1107-1113
    • /
    • 2002
  • This study presents the hydrogen emblittlement in the metal, which decreases the ductility and then induces the brittle fracture. The contribution deals with the effect of strain rate and notch geometry on hydrogen emblittlement of 1.25Cr-0.5Mo and 2.25Cr-1Mo steels, which are in use at high pressure vessel. Smooth and notched specimens were examined to obtain the elongation and tensile strength. For charging the hydrogen in the metal, the cathodic electrolytic method was used. In this process, current density is maintained constant. The amount of hydrogen penetrated in the specimen was detected by the hydrogen determenator(LECO RH404) with the various charging time. The distribution of hydrogen concentration penetrated in the specimen was obtained by finite element analysis. The amount of hydrogen is high in smooth specimen and tends to concentrate in the vicinity of surface. The elongation and tensile strength decreased with the passage of charging time in 1.25Cr-0.5Mo and 2.25Cr-1Mo steels. The elongation increased and tensile strength decreased as strain rate increased. As a result of this study, it is supposed that 1.25Cr-0.5Mo steel is more sensitive than 2.25Cr-lMo steel in hydrogen embrittlement. Hydrogen embrittlement susceptibility of notched specimen after hydrogen charging is more remarkable than that of smooth specimen.

Transition Temperature Evaluation of 1Cr-1Mo-0.25V Steel Using Miniaturized Charpy Impact Specimen (소형 샤르피 충격시험편을 이용한 1Cr-1Mo-0.25V강의 천이온도 평가)

  • Nahm Seung Hoon;Kim Si Cheon;Lee Hae Moo
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.42-46
    • /
    • 1998
  • Miniaturized specimen technology Permits mechanical behavior to be determined using a minimum volume of material. The technology is useful in case of not collecting a large amount of materials from industrial equipments. Five kinds of accelerated degradation materials were prepared by isothermal aging heat treatment at $630^{\circ}C$. Three kinds of specimens were prepared for impact testing. In order to increase plastic constraint of subsize specimen, side-groove was introduced. Results between subsize and full size impact testing were compared. Size effects correlations were developed for the impact properties of turbine rotor material. These correlations successfully predict the ductile brittle transition temperature (DBTT) of full size Charpy impact specimens based on subsize specimen data.

  • PDF

PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens (금속 시편 형태에 따른 PEC 초음파 제염 성능)

  • Won Hui-Jun;Kim Gye-Nam;Jung Chung-Hun;Park Jin-Ho;Oh Won-Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.293-300
    • /
    • 2005
  • Ultrasonic decontamination of the type 304 stainless steel specimen loosely contaminated with $Eu_2O_3$ powders was investigated. Decontamination factors (DFs) by the three kinds of ultrasonic media such as water, pure PFC (Pefluorocarbon, $C_7F_{16}$) and a mixed solution of $99.9\;vol\%\;PFC\;and\;0.1\;vol\%$ anionic surfactant were determined. The determined DF values were 20, 50 and 200, respectively. This significant difference in the decontamination factors for the different decontamination solution was well explained by the surface tension of the media as well as the interaction between the positively charged surface of $Eu_2O_3$ powders and the anionic surfactant. Ultrasonic decontamination behavior of the loosely contaminated metal specimens such as plate, pipe, welding specimen and crevice specimen in the mixed solution of PFC and anionic surfactant was also investigated. The contaminants were completely removed for the tested specimens except for the longest specimen. For 6-cm long pipe specimen, however, $98.5\%$ of the contaminants were removed.

  • PDF

The Penetration Characteristics of CFRP Laminated Shells on the Change of Stacking Sequences and Curvatures (적층구성 및 곡률 변화에 따른 CFRP 적층쉘의 관통특성)

  • Cho, Young-Jea;Kim, Young-Nam;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.79-85
    • /
    • 2006
  • CFRP(Carbon Fiber Reinforced Plastics) of the advanced composite materials as structural materials for vehicle, has a wide application in light-weigh structural materials of airplanes, ships and automobiles because of high strength and stiffness, However, there is a design variable to be considered in practical application of the laminate composite materials, these materials are vulnerable to transverse impact. This paper is to study the effects of stacking sequence and curvature on the penetration characteristics of composite laminate shell. They are stacked to $[0_3/90_3]S,\;[90_3/0_3]s\;and\;[0_2/90_3/0]s,\;[90_2/0_3/90]s$ and their interlaminar number two and four. They are manufactured to various curvature radius (R=100, 150, 200mm and $\infty$), When the specimen is subjected to transverse impact by a steel ball, the velocity of the steel ball was measured both before and after impact by determing the time for it to pass two ballistics-screen sensors located a known distance apart. The critical penetration energy of specimen A and B with less interfaces were a little higher than those of C and D. As the curvature increases, the critical penetration energy increases linearly because the resistance to the in-plane deformation as well as bending deformation increases, which need higher critical penetration energy. The specimen A and C have higher critical penetration energy than B and D because of different stacking sequences. We examined crack length through a penetration test. For the specimen A with 2interfaces, the longest circumferential direction crack length were observed on the first interface from the impact point. For the specimen B 4-interface, the longest circumferential direction crack length were observed on the second interface from the impact point.

Relationship between the Applied Torque and CCT to obtain the Same Corrosion Resistance for the Plate and Cylindrical Shape Stainless Steels

  • Chang, Hyun Young;Kim, Ki Tae;Kim, Nam In;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.58-68
    • /
    • 2016
  • Many industries need the universal standard or technique to obtain the identical CCT regardless of specimen geometries. This study aimed to determine an appropriate applied torque to the cylindrical specimen defining the apparatus and the procedure to measure the temperature of initiating crevice corrosion in tubular shape products such as pipes, tubes and round rods etc; the test method also proved applicable to the plate type specimen. A series of experiments for CCT measurements with the plate type and cylindrical stainless steel specimens of various diameters with different microstructures (austenitic and duplex) and PRENs were conducted to determine the relationship among geometries on CCT. Thus, the apparatus that could measure the CCT of stainless steels with both plate and cylindrical geometries was newly designed. The use of the apparatus facilitated the same CCT value for both geometries only if the specimens were made of the same alloy. The applied torque can be calculated for various diameters of the cylindrical specimens using the following relation; Applied torque, $Nm=-0.0012D^2+0.019D+2.4463$ (D; the diameter of cylindrical specimen, mm). However, upwards of 35 mm diameter cylindrical specimens require 1.58Nm, which is the same torque for the plate type specimen; in addition, this test method cannot be used for cylindrical specimens of less than 15 mm diameter.

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.