• Title/Summary/Keyword: steady-state current

Search Result 815, Processing Time 0.028 seconds

The three dimensional measuring system for ELF magnetic fields with the multiturn loop-type sensors (멀티턴 루우프형 센서를 이용한 3차원 ELF 자장측정계)

  • Lee, Bok-Hee;Lee, Jeong-Gee;Kil, Gyung-Suk;Ahn, Chang-Hwan;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.29-36
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of extremely low frequency(ELF) magnetic fields caused by starting and/or operating electric devices and power installations can be conducted. To obtain high performance for lower frequency and spatial components without any distortion, the measuring system is designed as three dimensionally including the multiturn loop-type magnetic field sensors, differential amplifiers and active integrators. As the results of calibration experiments, the frequency response characteristics of the measuring system range from 8[Hz] to about 53[kHz] for each direction of x, y, z axes, and the response sensitivities are 9.54, 9.21, $10.89[mV/{\mu}T]$, respectively. The actual survey experiments by using an oscillating impulse current generator confirm a reliability of the proposed measuring system. Also, through the other experiments by using small-sized induction motors, the magnetic field intensities when starting and steady-state operating mark 15.8, $8.61[{\mu}T]$ as maximum value, respectively. And those intensities decrease steeply according as the measuring distance increases.

  • PDF

Electromagnetic Flapping Shutters for Phone Cameras (폰 카메라용 전자기력 Flapping 셔터)

  • Choi, Hyun-Young;Han, Won;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1385-1391
    • /
    • 2010
  • In this study, we present small-size, low-power, and high-speed electromagnetic flapping shutters for phone cameras. These shutters are composed of trapezoidal twin blades suspended by H-type torsional springs. The existing electrostatic rolling and flapping shutters need high input voltage, while the existing electromagnetic rotating shutters are too big to be used for phone cameras. To achieve low-power and high-speed angle motion for small-size electromagnetic flapping shutters for camera phones, low-inertia trapezoidal twin blades, each suspended by the low-stiffness H-type torsional springs, are employed. The electromagnetic flapping shutters used in this experimental study have steady-state rotational angles of $48.8{\pm}1.4^{\circ}$ and $64.4{\pm}1.0^{\circ}$ in the magentic fields of 0.15 T and 0.30 T, respectively, for an input current of 60 mA; the maximum overshoot angles are $80.2{\pm}3.5^{\circ}$ and $90.0{\pm}1.0^{\circ}$ in the magentic fields of 0.15 T and 0.30 T, respectively. The rising/settling times of the shutter while opening are 1.0 ms/20.0 ms, while those while closing are 1.7 ms/10.3 ms. Thus, we experimentally demonstrated that the smallsize (${\sim}8{\times}8{\times}2\;mm^3$), low-power (${\leq}60\;mA$), and high-speed (~1/370 s) electromagnetic flapping shutters are suitable for phone cameras.

Impedance Parameters of Electrical Double Layer I. A Determination Method of Electrolytic Cell Impedance Parameter on the Platinum Electrode (전기이중층의 임피던스 파라미터 I. 백금전극을 사용한 전해쎌 임피던스 파라미터의 결정방법)

  • Kum-Sho Hwang;Un-Sik Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.273-281
    • /
    • 1986
  • This study is focused on the correct measurement of the equations for the determination of the impedance parameters-the differential capacity of the double layer $C_d$, solution resistance $R_Q$, transfer resitance $R_i$, and adsorption pseudcapacity $C_{\phi}$/ The application of only an imaginary part of complex function of ${\omega}$ at the sinusoidal steady state indicates the following equations of total impedance: at low frequency $|Z_{LF}|=1/{\omega}_1\;C_{\phi}\;{\sqrt{1+{{\omega}_1}^2/{\omega}^2}$, at high frequency $|Z_{HF}|={\omega}_2/({\omega}_1{\omega}_3C{\phi})({\omega}^2+{{\omega}_2}^2)\;{\sqrt{{({\omega}^2+{\omega}_2{\omega}_3)}^2+{({\omega}_2{\omega}-{\omega_3{\omega})^2}}$. The values of the total impedance of cell, phase angle, and cell current that are necessary for the calculations of impedance parameters were experimentally measured from 200 to 6000Hz for the following supporting electrolytes, 0.5M $Na_2SO_4$, 1M NaCl, 19.373% sea water, 1M HCl, 1M $KNO_3$ and for $10^{-2}M$ KI and 60mM DBNA (Di-iso-Butylnitrosoamine) in these supporting electrolytes. The derived equations in this study shows that the values of impedance parameters of $C_d,\;C_{\phi},\;R_i\;and\;R_Q\;are\;15{\sim}40\;{\mu}F/cm^2,\;162{\sim}758\;{\mu}F/cm^2\;11.5{\sim}57.6\;ohm{\cdot}cm^2\;and\;0.5{\times}10^{-2}{\sim}4.1{\times}10^{-2}\;ohm{\cdot}cm^2$ respectively.

  • PDF

A Comparative Study on Effective Factors Related to Home Nursing Care in Hospital and Community-based Care in Korea (한국 가정간호사업의 유형별 비교분석)

  • Kim, Sung-Sil
    • Research in Community and Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.181-199
    • /
    • 1998
  • This study was designed to examine Home Nursing Care in Hospital-based and Community-based programs. This study investigates actual conditions of nursing needs and demands of clients and their family and the state of home nursing services. We hope that this study will improve upon the current home nursing care system. In Korea Home-Nursing Care programs are still developing and only now becoming a part of the health care delivery system. The data was collected by a questionaire the clients developed and modified through literature review by this writer and through 10 nurses who are members of 4 hospital and 3 community- based agencies. In this study 173 clients were selected. The study lasted from Oct. 1997 to March of 1998. The results show that the average age was 64.3, years older than most women clients (63.0%), the average age of a caregiver was 50.9 years old and most were female(77%). Two types of agency clients with a significant difference between social conditions [25.7%] used some form of insurance; 54.3% had the spouse pay expenses; pay 58.5% son and daughters of Hospital-based agencies: patients of social workers were 24.0%, the highest in the community agency. The condition of patients was 63.2% of the foley and nelaton catheter insertion at hospital based agencies. The range of nursing services offered is one of the highest among the 34 kinds of servies including nasogastric tube management basic nursing, ROM exercise, bladder irrigation, wound and sore dressing. For an effective care service factors that disturb each program such as a non-cooperatative family as well as patients themselves need to be lessened. Further more, the following must be emphasized, supportive counsel 27.0%, steady care for patient, 13.3%maintain a sense of security(11.7%), dressing sores and nutrition(10.0%). Although there were a large number of home nursing care services in the community, policy changes have gathered momentum. Fortunately, the scope and level at legal support will be increased in the future. The program should intergrate and link the district or community together. A project to develop a community based home nursing system as soon as possible should be developed. In conclusion, home nursing care nurses training curriculum should be strengthened.

  • PDF

Dynamic Control Allocation for Shaping Spacecraft Attitude Control Command

  • Choi, Yoon-Hyuk;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.1
    • /
    • pp.10-20
    • /
    • 2007
  • For spacecraft attitude control, reaction wheel (RW) steering laws with more than three wheels for three-axis attitude control can be derived by using a control allocation (CA) approach.1-2 The CA technique deals with a problem of distributing a given control demand to available sets of actuators.3-4 There are many references for CA with applications to aerospace systems. For spacecraft, the control torque command for three body-fixed reference frames can be constructed by a combination of multiple wheels, usually four-wheel pyramid sets. Multi-wheel configurations can be exploited to satisfy a body-axis control torque requirement while satisfying objectives such as minimum control energy.1-2 In general, the reaction wheel steering laws determine required torque command for each wheel in the form of matrix pseudo-inverse. In general, the attitude control command is generated in the form of a feedback control. The spacecraft body angular rate measured by gyros is used to estimate angular displacement also.⁵ Combination of the body angular rate and attitude parameters such as quaternion and MRPs(Modified Rodrigues Parameters) is typically used in synthesizing the control command which should be produced by RWs.¹ The attitude sensor signals are usually corrupted by noise; gyros tend to contain errors such as drift and random noise. The attitude determination system can estimate such errors, and provide best true signals for feedback control.⁶ Even if the attitude determination system, for instance, sophisticated algorithm such as the EKF(Extended Kalman Filter) algorithm⁶, can eliminate the errors efficiently, it is quite probable that the control command still contains noise sources. The noise and/or other high frequency components in the control command would cause the wheel speed to change in an undesirable manner. The closed-loop system, governed by the feedback control law, is also directly affected by the noise due to imperfect sensor characteristics. The noise components in the sensor signal should be mitigated so that the control command is isolated from the noise effect. This can be done by adding a filter to the sensor output or preventing rapid change in the control command. Dynamic control allocation(DCA), recently studied by Härkegård, is to distribute the control command in the sense of dynamics⁴: the allocation is made over a certain time interval, not a fixed time instant. The dynamic behavior of the control command is taken into account in the course of distributing the control command. Not only the control command requirement, but also variation of the control command over a sampling interval is included in the performance criterion to be optimized. The result is a control command in the form of a finite difference equation over the given time interval.⁴ It results in a filter dynamics by taking the previous control command into account for the synthesis of current control command. Stability of the proposed dynamic control allocation (CA) approach was proved to ensure the control command is bounded at the steady-state. In this study, we extended the results presented in Ref. 4 by adding a two-step dynamic CA term in deriving the control allocation law. Also, the strict equality constraint, between the virtual and actual control inputs, is relaxed in order to construct control command with a smooth profile. The proposed DCA technique is applied to a spacecraft attitude control problem. The sensor noise and/or irregular signals, which are existent in most of spacecraft attitude sensors, can be handled effectively by the proposed approach.

MIS Curriculum : The Current State of the Art and a Proposed Future Model (MIS 커리큘럼 현황 및 발전모델)

  • Lee, Kuk-Hie;Kim, Sung-Kun;Lee, Jo-Hn;Kim, Yong-Jae;Lee, Ho-Joon
    • Information Systems Review
    • /
    • v.9 no.3
    • /
    • pp.1-32
    • /
    • 2007
  • Recently, Korean universities have experienced steady decline in enrollments in MIS majors, which raises a serious concern to both academia and business leaders as well. With roles of MIS in corporate worlds are expanding and demands for newer breeds of MIS graduates ever growing, this trend, also observed in the US, poses a puzzling yet interesting research agenda. To come to grips with the problem and to suggest a robust curricula model for the future, this paper approaches the problem from various angles. The model first examines perceptions on MIS of Korean students; it then delineates existing curricula models to identify core MIS courses. The compilation is then juxtaposed by MIS course information from major US and Korean colleges, leading to categorizing major MIS subfields. The paper then tries to identify as-is and desired status of MIS curriculum, based on inquiry results from both academia and IS practitioners. Together with career tracks concretely described in this paper, the model would serve to fill the perception gaps in and to meet the future goals for MIS education in Korea.

Long Tenn Water Quality Prediction using an Eco-hydrodynamic Model in the Asan Bay (생태-유체역학모델을 이용한 아산만 해양수질의 장기 예측)

  • Kwoun, Chul-Hui;Kang, Hoon;Cho, Kwang-Woo;Maeng, Jun-Ho;Jang, Kyu-Sang;Lee, Seung-Yong;Seo, Jeong-Bin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • The long-term water-quality change of Asan Bay by the influx of polluted disposal water was predicted through a simulation with an Eco-hydrodynamic model. Eco-hydrodynamic model is composed of a multi-level hydrodynamic model to simulate the water flow and an ecosystem model to simulate water quality. The water quality simulation revealed that the COD(Chemical Oxygen Demand), dissolved inorganic nitrogen(DIN) and dissolved inorganic phosphorus(DIP) are increased at 5 stations for the subsequent 6 months after the influx of the effluent. COD, DIN and DIP showed gradual decreases in concentration during the period of one to two years after the increase of last 6 months and reached steady state for next three to ten years. Concentration levels of COD, DIN, and DIP showed the increase by the ranges of $11{\sim}67%$, $10{\sim}67%$, and $0.5{\sim}7%$, respectively, which represents that the COD and DIN are the most prevalent pollutants among substances in the effluent through the sewage treatment plant. The current water quality of Asan Bay based on the observed COD, TN and TP concentrations ranks into the class II of the Korean standards for marine water quality but the water quality would deteriorate into class III in case that the disposal water by the sewage plant is discharged into the Bay.

  • PDF

ECSS E70 Standard for developing common EGSE and MCS (전기지상지원장비 및 관제시스템 통합 개발을 위한 유럽 표준안 현황)

  • Huh, Yun-Goo;Choi, Jong-Yeoun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.56-64
    • /
    • 2008
  • Although the EGSE (Electrical Ground Support Equipment) and MCS (Mission Control System) have many similar or even identical functions, the EGSE used for assembly, integration and validation phase and the MCS for the mission operations phase are normally developed separately and used by different groups of engineers. However, the common ground system for EGSE and MCS has developed and many space missions such as PROBA (PRoject for On-Board Autonomy), ROSETTA, MARS EXPRESS, CRYOSAT (Cryosphere Satellite), GOCE (Gravity field and steady state Ocean Circulation Explorer), and GALILEO have used or will use it to minimize risk, reduce cost and improve overall product quality. It is based on ECSS (European Cooperation for Space Standards) E70 which is the international standard for ground systems and operations published by ECSS E70 Working Group. The ECSS E70 contains the basic rules, principles and requirements applied to the engineering of the ground systems and the execution of mission operations. This paper introduces standardization policy, organization and standard documentation in ECSS. The overview of ECSS E70 such as status, purpose and contents is also described in this paper.

  • PDF

Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System (직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘)

  • Kim, Ki-Young;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.528-535
    • /
    • 2020
  • Recently, the protection coordination method of DC systems has been presented because renewable energy and distributed resources are being installed and operated in distribution systems. On the other hand, it is difficult to detect ground faults because there is no significant difference compared to a steady-state current in ungrounded IT systems, such as DC load networks and urban railways. Therefore, this paper formulates the detection principle of IMD (Insulation Monitoring Device) to use it as a protection coordination device in a DC system. Based on the signal injection method of IMD, which is analyzed by a wavelet transform, this paper presents an algorithm of detecting ground faults in a DC system in a fast and accurate manner. In addition, this paper modeled an IMD and an ungrounded DC system using the PSCAD/EMTDC S/W and performed numerical analysis of a wavelet transform with the Matlab S/W. The simulation results of a ground fault case in an ungrounded DC system showed that the proposed algorithm and modeling are useful and practical tools for detecting a ground fault in a DC system.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.