A PWM method using fuzzy logic for brushless motor drives (브러시리스 전동기 제어를 위한 퍼지제어 PWM)

  • Chin, Myung-Churl;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1235-1237
    • /
    • 1992
  • In this paper, a new PWM method and estimating means of rotor position angles for BLDC motor drive are presented. The rotor position angles is predicted by calculated rotor flux from the stator voltage and current signals. The current control PWM using fuzzy logic is also suggested. Performance of the proposed controller is observed through a simulation.

  • PDF

Sensorless Vector Control of Induction Motor Using the Flux Estimator (자속추정기를 이용한 유도전동기 센서리스 벡터제어)

  • 김경서;조병국
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.87-92
    • /
    • 2003
  • This paper presents a flux estimator for the sensorless vector control of induction motors. The proposed method utilize the combination of the voltage model based on stator equivalent model and the current model based on rotor equivalent model, which enables stable estimation of rotor flux in high speed region and in low speed region. The dynamic performance of proposed method is verified through the experiment. The experimental results show that motors ran easily start even under 150[%] load condition and operate continuously below 0.5[Hz].

High Frequency Model of Inverter-fed Induction Motor (인버터 구동 유도 전동기 고주파 모델링)

  • Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.795-797
    • /
    • 2001
  • Voltage varing Fate dv/dt which is applied to induction motor usually makes unnegligible leakage current and it flows through stator winding and motor frame. This kind of harmonic leakage current makes effect on power source and cuases electromagnetic trouble because the motor frame has earth. Therefore in this study, a high frequency induction motor model is developed and analyze the motor performance to explain the phenomena. Inverter model is also developed and is combined with the motel model to prepare the basis of the high frequency effects on inverter fed induction motor.

  • PDF

A Study on the Torque Ripple Reduction of Low Voltage High Current SPMSM (저전압 대전류 SPMSM 토크리플 저감 제어)

  • Lee, Geun-Ho;Hong, Jeong-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2391-2395
    • /
    • 2009
  • Active control schemes which modify the excitation to correct for any of the nonideal characteristics of the SPMSM is described. Especially, because of design limitations(size and cost) in automobile, the back-EMF of SPMSM can't be perfectly designed with sinusoidal wave and iron core of stator is saturated so that torque ripple is unavoidable. An active cancellation method of the pulsating torque components which would otherwise be generated using the classic sinusoidal current excitation is illustrated.

The Analysts of PerformaneeCharacterlstics of a L.I.M. with taken into Conslderatlon of End Effects(l) (단부효과를 고려한 L.I.M.의 동작특성 해석 (1))

  • 임달호;이은웅;장석명
    • 전기의세계
    • /
    • v.31 no.4
    • /
    • pp.288-295
    • /
    • 1982
  • In this study, the characteristic equation of a double sided short stator linear induction motor, referred to as LIM excited by equivalent current sheet having linear current density was derived using Maxwell's electromagnetic field theory with its entry and exit, end effects taken into consideration. According to the treatment of several physical phenomena in the air-gap i.e. the magnetic flux density distributions, thrust-force, forward and backward travelling wave with decay, normal field, the fundamental data in this study are made reference to improve the characteristics of LIM, effectual electro-magnetic energy conversion devices.

  • PDF

A study developing control algorithm for Pumped-Storage Synchronous motor drive (양수발전소 동기전동기의 기동제어 알고리즘에 관한 연구)

  • Kang S.W.;Park S.H.;Kim J.M.;Lim I.H.;Ryu H.S.;Kim J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.467-471
    • /
    • 2003
  • The large synchronous motor for the pumped-storage plant(or SFC : Static Frequency Converter) has to be brought up to 100$\%$ rated speed and synchronized with the AC power network. Starting the motor from rest is achieved by switching current into the stator winding so that interaction between this stator current and the rotor flux will cause the correct direction of torque to be developed so that the motor turns in the required direction. Starting ranges of the synchronous motor are divided into three regions. The first region Is at standstill, the second that is called by the forced commutation is from standstill to 5-8$\%$ of rated speed, and the third, which is called by the natural commutation, is from 5-8$\%$ of rated speed to 100$\%$ rated speed. So this paper describes three regions of the control techniques of the pumped-storage synchronous motor drive.

  • PDF

Optimal PAM Control for a Buck Boost DC-DC Converter with a Wide-Speed-Range of Operation for a PMSM

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Senjyu, Tomonobu;Yona, Atsushi;Saber, Ahmed Yousuf
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.477-484
    • /
    • 2010
  • A pulse width modulation-voltage source inverter (PWM-VSI) is used for variable speed permanent magnet synchronous motor (PMSM) drives. The PWM-VSI fed PMSM has two major disadvantages. Firstly, the PWM-VSI DC-link voltage limits the magnitude of the PMSM terminal voltage. As a result, the motor speed is restricted. Secondly, in a low speed range, the PWM-VSI modulation index declines. This is caused by a high DC-link voltage and a low terminal voltage ratio. As a result, the distortion of the voltage command and the stator current are increased. This paper proposes an optimal pulse amplitude modulation (PAM) control which can adjust the inverter DC-link voltage by using a buck-boost DC-DC converter. At a low speed range, the proposed system can reduce the distortion of the voltage command, which improves the stator current waveform. Also, the allowable speed range is extended. In order to verify the proposed method, experimental results are provided to confirm the simulation results.

Sensorless Control of Induction Motors with Simultaneous Estimation of Speed and Rotor Resistance in the Very Low Speed Region (속도와 2차 저항의 동시 추정이 가능한 유도전동기의 극 저속 영역 센서리스 속도제어)

  • 정석권;이진국;유삼상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.552-561
    • /
    • 2004
  • This paper is concerned with a new speed sensorless induction motor scheme which can be successfully applied to at any speed including even zero speed. The proposed method is robust against rotor resistance variations. In addition, simultaneous on-line estimations of speed and rotor resistance are realized based on a feedforward type torque control approach. The rotor flux with a low frequency sinusoidal waveform has been utilized to help the simultaneous estimation for both speed and rotor resistance. The control scheme has no current minor loop to determine voltage references. Since the proposed estimation does not depend on any derivative terms of currents and stator voltages, it offers a good performance at extremely low speed region for sensorless induction motor. Furthermore, the proposed control is simply using motor parameters and stator currents without determining any PI gains for current feedback and any signal injection for the rotor resistance estimation. Finally, both simulation and experimental results are given to show the effectiveness of this method.

Analysis of the Operational Characteristics of Superconducting Power supply Considering the structure of the Sheets (박막구조에 따른 초전도전원장치의 동작특성 해석)

  • Kim, Ho-Min;Yoon, Yong-Soo;Ahn, Min-Cheol;Ko, Tae-Kuk;Han, Tae-Su;Oh, Sang-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.164-169
    • /
    • 2001
  • This paper deals with comparison of characteristics of continuous-sheet type low-Tc superconducting (LTS) power supply and discrete-sheet type LTS power supply. These characteristics have been analyzed through experiments. These power supplies consist of two exciters, a rotor, a stator, and a LTS load. A continuous-sheet type has a single continuous niobium (Nb) sheet attached to the inner surface of on the stator. In the case of discrete-sheet type, four separated Nb sheets are used. this experiment is using 1.81 mH LTS magnet load and maximum 30 A dc exciter current. A discrete-sheet type is expected to produce much better pumping rate than a continuous-sheet type. The experimental observations have been compared with the theoretical predictions. In this experiment, the maximum pumping-current has reached about 926 A.

  • PDF

Decoupling Vector Control for a High-Speed Synchronous Reluctance Motor (고속 동기 릴럭턴스 전동기의 비간섭 벡터제어)

  • 백동기;성세진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.128-135
    • /
    • 1998
  • In the high speed range for salient type synchronous reluctance motor, the effect of iron loss can not be negligible. In this paper, under he assumption that stator iron loss is generated from the equivalent eddy current in the stator, we derive the voltage equations including iron loss from the model that is added the equivalent iron loss in the equivalent inductance in series. The variation of iron loss is dependent on the increase of the operating frequency change for he worse a performance of the vector control system. As there is cross coupling between the d and q axes, it is hard to apply the vector control to the proposed model. Hence, we propose a decoupling current controller for including the effects of iron loss, And we show that the proposed vector control scheme achieves the desired performances through simulation results.

  • PDF