• Title/Summary/Keyword: statistical confidence

Search Result 1,002, Processing Time 0.045 seconds

A Study on the Relationship between TLO Organization and Technology Transfer Performance: Focused on Government-Funded Research Institutes (TLO 조직과 기술이전 성과의 관계에 관한 연구: 정부출연연구기관을 중심으로)

  • Yun, Jang-ho
    • Journal of Technology Innovation
    • /
    • v.25 no.4
    • /
    • pp.165-187
    • /
    • 2017
  • This study analyzed the effects of TLO's organization size, expertise, and economic compensation on technology transfer performance using the panel data of Government-Funded Research Institutes in 2013-2016. First, the size of TLO personnel and budget have a positive effect on the technology transfer performance. However, in the case of TLO manpower, the statistical significance of the effect on the number of technology transfers was only 90%, and it did not affect royalty. Second, TLO expertise has a strong impact on technology transfer performance. It shows that the number of professional license holders, such as patent attorney or a technology valuer, has a statistically significant effect on the increase of the technology transfer number and the royalty under the 99% confidence level. However, unlike expected, the size of the Ph.D. did not seem to have any effect on technology transfer performance. Finally, the economic compensation for TLO does not affect both the number of technology transfers and the royalty. It does not seem to work as an appropriate incentive system, because the absolute size of the compensation is too small. The results of the above analysis suggest that it is important to secure expertise in order for the TLO organization to play a substantial role, and it is necessary to improve the economic compensation system to attract TLOs to technology transfer.

Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations

  • Choi, Woo Jung;Cha, Joo Hee;Kim, Hak Hee;Shin, Hee Jung;Kim, Hyunji;Chae, Eun Young;Hong, Min Ji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9101-9105
    • /
    • 2014
  • Background: The purpose of this study was to compare the accuracy and effectiveness of automated breast volume scanning (ABVS) and hand-held ultrasound (HHUS) in the detection of breast cancer in a large population group with a long-term follow-up, and to investigate whether different ultrasound systems may influence the estimation of cancer detection. Materials and Methods: Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From September 2010 to August 2011, a total of 1,866 ABVS and 3,700 HHUS participants, who underwent these procedures at our institute, were included in this study. Cancers occurring during the study and subsequent follow-up were evaluated. The reference standard was a combination of histology and follow-up imaging (${\geq}12months$). The recall rate, cancer detection yield, diagnostic accuracy, sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were calculated with exact 95% confidence intervals. Results: The recall rate was 2.57 per 1,000 (48/1,866) for ABVS and 3.57 per 1,000 (132/3,700) for HHUS, with a significant difference (p=0.048). The cancer detection yield was 3.8 per 1,000 for ABVS and 2.7 per 1,000 for HHUS. The diagnostic accuracy was 97.7% for ABVS and 96.5% for HHUS with statistical significance (p=0.018). The specificity of ABVS and HHUS were 97.8%, 96.7%, respectively (p=0.022). Conclusions: ABVS shows a comparable diagnostic performance to HHUS. ABVS is an effective supplemental tool for mammography in breast cancer detection in a large population.

Temporal Change in Radiological Environments on Land after the Fukushima Daiichi Nuclear Power Plant Accident

  • Saito, Kimiaki;Mikami, Satoshi;Andoh, Masaki;Matsuda, Norihiro;Kinase, Sakae;Tsuda, Shuichi;Sato, Tetsuro;Seki, Akiyuki;Sanada, Yukihisa;Wainwright-Murakami, Haruko;Yoshimura, Kazuya;Takemiya, Hiroshi;Takahashi, Junko;Kato, Hiroaki;Onda, Yuichi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.128-148
    • /
    • 2019
  • Massive environmental monitoring has been conducted continuously since the Fukushima Daiichi Nuclear Power accident in March of 2011 by different monitoring methods that have different features together with migration studies of radiocesium in diverse environments. These results have clarified the characteristics of radiological environments and their temporal change around the Fukushima site. At three months after the accident, multiple radionuclides including radiostrontium and plutonium were detected in many locations; and it was confirmed that radiocesium was most important from the viewpoint of long-term exposure. Radiation levels around the Fukushima site have decreased greatly over time. The decreasing trend was found to change variously according to local conditions. The air dose rates in environments related to human living have decreased faster than expected from radioactive decay by a factor of 2-3 on average; those in pure forest have decreased more closely to physical decay. The main causes of air dose rate reduction were judged to be radioactive decay, movement of radiocesium in vertical and horizontal directions, and decontamination. Land-use categories and human activities have significantly affected the reduction tendency. Difference in the air dose rate reduction trends can be explained qualitatively according to the knowledge obtained in radiocesium migration studies; whereas, the quantitative explanation for individual sites is an important future challenge. The ecological half-lives of air dose rates have been evaluated by several researchers, and a short-term half-life within 1 year was commonly observed in the studies. An empirical model for predicting air dose rate distribution was developed based on statistical analysis of an extensive car-borne survey dataset, which enabled the prediction with confidence intervals. Different types of contamination maps were integrated to better quantify the spatial data. The obtained data were used for extended studies such as for identifying the main reactor that caused the contamination of arbitrary regions and developing standard procedures for environmental measurement and sampling. Annual external exposure doses for residents who intended to return to their homes were estimated as within a few millisieverts. Different forms of environmental data and knowledge have been provided for wide spectrum of people. Diverse aspects of lessons learned from the Fukushima accident, including practical ones, must be passed on to future generations.

Factors Related to Exertional Oxygen Desaturation in Patients with COPD (만성 폐쇄성 폐질환(COPD) 환자에서 운동 시 발생하는 산소 불포화 반응과 관련된 인자)

  • Shim, Sang-Woo;Jo, Jun-Yeon;Kwon, Yong-Sik;Chae, Jin-Nyeong;Park, Jie-Hae;Lee, Mi-Young;Rho, Byung-Hak;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.6
    • /
    • pp.498-503
    • /
    • 2011
  • Background: The causes of exertional desaturation in patients with COPD can be multifactorial. We aimed to investigate factors predict exertional desaturation in patients with moderate to severe COPD. Methods: We tested 51 consecutive patients with stable COPD (FEV1/FVC, $40{\pm}13%$ predicted). Patients performed a six minute walk test (6MWT). Pulse oxymetric saturation (SpO2) and pulse rate were recorded. Results: Oxygen desaturation was found in 15 subjects after 6MWT, while 36 subjects were not desaturated. Lung diffusing capacity was significantly lower in desaturation (DS) group ($62{\pm}18%$ predicted) compared with not desaturated (ND) group ($84{\pm}20$, p<0.01). However there was no statistical difference of FEV1/FVC ratio or residual volume between two groups. The pulse rate change was significantly higher in the desaturated compared with the not desaturated group. Six minute walking distance, subjective dyspnea scale, airflow obstruction, and residual volume did not predict exertional oxygen desaturation. Independent factors assessed by multiple logistic regression revealed that a pulse rate increment (odd ratio [OR], 1.19; 95% confidence interval [CI], 1.01~1.40; p=0.02), a decrease in baseline PaO2 (OR, 1.105; 95% CI, 1.003~1.218; p=0.04) and a decrease in lung diffusing capacity (OR, 1.10; 95% CI, 1.01~1.19; p=0.01) were significantly associated with oxygen desaturation. Receiver operator characteristic (ROC) analysis showed that an absolute increment in pulse rate of 16/min gave optimal discrimination between desaturated and not desaturated patients after 6MWT. Conclusion: Pulse rate increment and diffusion capacity can predict exertional oxygen desaturation in stable COPD patients with moderate to severe airflow obstruction.

Bioequivalence of Procezil Tablet 250 mg to $Cefzil^{(R)}$ Tablet 250 mg (Cefprozil 250 mg) (세프질$^{(R)}$ 정 250밀리그람 (세프프로질 250밀리그람)에 대한 프로세질 정 250밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Kang, Min-Sun;Cho, Hea-Young;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.255-261
    • /
    • 2010
  • Cefprozil is a broad-spectrum oral beta-lactam cephalosporin consisting of cis- and trans-isomeric mixture whose ratio is approximately 90:10. Cefprozil is used to treat certain infections caused by bacteria such as bronchitis and ear, skin, and throat infections. The purpose of the present study was to evaluate the bioequivalence of two cefprozil tablets, $Cefzil^{(R)}$ tablet 250 mg (BMS Pharmaceutical Korea., Ltd.) and Procezil tablet 250 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of cefprozil from the two cefprozil formulations were tested using KP VIII Apparatus I method with water dissolution media. Thirty five healthy male subjects, $24.00{\pm}1.53$ years in age and $69.77{\pm}9.99$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After four tablets containing 1000 mg as cefprozil were orally administered, blood samples were taken at predetermined time intervals and the concentrations of cefprozil in serum were determined using HPLC/UV detector. The dissolution profiles of two formulations were similar in water tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ on the basis of total-cefprozil were calculated, and computer program (K-BE Test 2002) was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Cefzil^{(R)}$ tablets, were -0.81%, -3.00% and -6.83% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.9515~log 1.0454 and log 0.9613~log 1.0465 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procezil tablet was bioequivalent to $Cefzil^{(R)}$ tablet.

Bioequivalence of Bambucol Tablet 10 mg to $Bambec^{(R)}$ Tablet 10 mg (Bambuterol Hydrochloride 10 mg) (밤벡$^{(R)}$ 정 10밀리그람(염산밤부테롤 10밀리그람)에 대한 밤부콜 정 10밀리그람의 생물학적동등성)

  • Cho, Hea-Young;Choi, Ji-Hoon;Yoo, Hee-Doo;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.235-241
    • /
    • 2010
  • Bambuterol hydrochloride, dimethylcarbamic acid 5-[2-(1,1-dimethylethyl)amino-1-hydroxyethyl]-1,3-phenylene ester hydrochloride, is the prodrug of active ${\beta}_2$-adrenergic metabolite terbutaline. The purpose of the present study was to evaluate the bioequivalence of two bambuterol hydrochloride tablets, $Bambec^{(R)}$ tablet 10 mg (Yuhan Co., Ltd.) and Bambucol tablet 10 mg (Sam Chun Dang Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). In vitro release of bambuterol from two bambuterol hydrochloride formulations was tested using KP VIII Apparatus II method with various dissolution media. Twenty eight healthy male Korean volunteers, $23.86{\pm}1.65$ years in age and $68.98{\pm}9.58$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two tablets containing 10 mg as bambuterol hydrochloride were orally administered, blood samples were taken at predetermined time intervals, and the concentrations of bambuterol in serum were determined using column switching HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test with K-BE Test 2002 was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Bambec^{(R)}$, were -8.10%, -3.82% and 12.65% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (i.e., log 0.8093~log 1.0302 and log 0.8564~log 1.1280 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Bambucol tablet 10 mg was bioequivalent to $Bambec^{(R)}$ tablet 10 mg.

Predicting Construction Project Cost using Sensitivity Analysis in Stochastic Project Scheduling Simulation (SPSS) (확률 통계적 일정 시뮬레이선 - 민감도 분석을 이용한 최종 공사비 예측)

  • Lee Dong-Eun;Park Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.4 s.26
    • /
    • pp.80-90
    • /
    • 2005
  • Activity durations retain probabilistic and stochastic natures due to diverse factors causing the delay or acceleration of activity completion. These natures make the final project duration to be a random variable. These factors are the major source of financial risk. Extending the Stochastic Project Scheduling Simulation system (SPSS) developed in previous research; this research presents a method to estimate how the final project duration behaves when activity durations change randomly. The final project cost is estimated by considering the fluctuation of indirect cost, which occurs due to the delay or acceleration of activity completion, along with direct cost assigned to an activity. The final project cost is estimated by considering how indirect cost behaves when activity duration change. The method quantifies the amount of contingency to cover the expected delay of project delivery. It is based on the quantitative analysis to obtain the descriptive statistics from the simulation outputs (final project durations). Existing deterministic scheduling method apply an arbitrary figures to the amount of delay contingency with uncertainty. However, the stochastic method developed in this research allows computing the amount of delay contingency with certainty and certain degree of confidence. An example project is used to illustrate the quantitative analysis method using simulation. When the statistical location and shape of probability distribution functions defining activity durations change, how the final project duration and cost behave are ascertained using automated sensitivity analysis method

Evaluation and Comparison of Signal to Noise Ratio According to Change of Kernel size of Heart Shadow on Chest Image (흉부 영상에서 커넬 크기변화에 따르는 신호대잡음비 비교평가)

  • Lee, Eul-Kyu;Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.443-451
    • /
    • 2017
  • The purpose of this study was to comparison of measure signal to noise ratio (SNR) according to change of kernel size from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 100 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p<0.05). In SNR results, with the quality of distributions in the order of kernel size 9*9 image, kernel size 7*7 image and original chest image, kernel size 3*3 image (p<0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the kernel size chest image.

Lifestyle and Metabolic Syndrome among Male Workers in an Electronics Research and Development Company (한 전자제품 연구소 남자 종사자들의 생활습관실천과 대사증후군의 관련성)

  • Myong, Jun-Pyo;Kim, Hyoung-Ryoul;Kim, Yong-Kyu;Koo, Jung-Wan;Park, Chung-Yill
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.5
    • /
    • pp.331-336
    • /
    • 2009
  • Objectives : The objectives of this study were to determine the relationship between lifestyle-implementation and metabolic syndrome in an electronics research and development company, and to provide a foundation for health providers of health management programs for setting priorities. Methods : From July 1 to July 16, 2008 we carried out a descriptive cross-sectional survey. Consecutive workers of one R & D company in Seoul, Korea (N=2,079) were enrolled in study. A checklist for lifestyle (from the National Health Insurance Corporation) consisted of questions regarding diet, drinking, smoking and exercise. After the survey, researchers obtained data from health profiles for metabolic syndrome(waist-circumference, triglycerides, HDL cholesterol, blood pressure and fasting blood sugar level). Lifestyle was recorded as good or not good. Statistical analysis of metabolic syndrome and the lifestyle of subjects was done using multiple logistic regression analysis. Results : The prevalence of metabolic syndrome in our study gropu was 13.3% (N=277). After adjustment for age, the adjusted odds ratios (odds ratio, 95% confidence intervals) for metabolic syndrome increased in proportion to the number of bad habits: two (1.72, 1.23-2.44), three (2.47, 1.73-3.56), and four (3.63, 2.03-6.34). Relative to subjects eating both vegetables and meat', the OR for 'meat' eaters was 1.66 (1.18-2.31). Compared with 'nonsmokers and ever-smoker', the OR for 'current-smoker' was 1.62 (1.25-2.10). Compared with 'Healthy drinker', the OR for 'unhealthy drinker' was 1.38 (1.05-1.83). Conclusions : Poor lifestyle was associated with an increased likelihood of metabolic syndrome. These findings suggest that lifestyle-based occupational health interventions for young employees should include a specific diet, smoking cessation, and healthy-drinking programs.

Relationship between Health Risk Behaviors and Toothbrushing among School-Going Adolescents in Poor Urban Areas of Peru (페루 도시 빈민 지역 청소년들의 칫솔질 빈도와 건강위험행동의 관련성)

  • Kim, Yeun Ju;Nam, Eun Woo
    • Journal of dental hygiene science
    • /
    • v.17 no.4
    • /
    • pp.315-322
    • /
    • 2017
  • The aim of this study was to explore the association between daily toothbrushing frequency and health risk behaviors of school-going adolescents in poor urban areas of Peru. A cross-sectional survey was conducted among 959 school-going adolescents 11~19 years of age in poor urban areas of Peru in 2014. Health risk behaviors we assessed in the study were smoking; drinking; consuming sugar-sweetened soft drinks (more than one cup); leisure time activities including watching television, playing games, and using the Internet; and never or rarely handwashing with soap. Daily toothbrushing frequency was divided into two groups (once and twice daily). For statistical analyses, the chi-square test and hierarchical logistic regression were used at 5% level of significance. Of the total respondents, 63 (14.3%) were boys and 53 (10.3%) were girls and 116 (12.1%) engaged in toothbrushing (${\leq}1$ times daily). According to the adjusted logistic regression analysis for socio-demographic characteristics, two behaviors (leisure time use activities, including watching television, playing games, and using the Internet (odds ratio [OR], 2.29; 95% confidence interval [CI], 1.20~4.35), and never or rarely hand washing with soap (OR, 4.09; CI, 2.48~6.75) were statistically associated with toothbrushing frequency (${\leq}1$ times daily). We found two health risk behaviors (leisure time activities, including watching television, playing games, and using the Internet, and never or rarely handwashing with soap) associated with toothbrushing frequency among adolescents in the study area. Thus, oral health promotion programs should consider these health risk behaviors associated with toothbrushing frequency.