• Title/Summary/Keyword: static parameters

Search Result 1,194, Processing Time 0.034 seconds

An applied model for steel reinforced concrete columns

  • Lu, Xilin;Zhou, Ying
    • Structural Engineering and Mechanics
    • /
    • v.27 no.6
    • /
    • pp.697-711
    • /
    • 2007
  • Though extensive research has been carried out for the ultimate strength of steel reinforced concrete (SRC) members under static and cyclic load, there was only limited information on the applied analysis models. Modeling of the inelastic response of SRC members can be accomplished by using a microcosmic model. However, generally used microcosmic model, which usually contains a group of parameters, is too complicated to apply in the nonlinear structural computation for large whole buildings. The intent of this paper is to develop an effective modeling approach for the reliable prediction of the inelastic response of SRC columns. Firstly, five SRC columns were tested under cyclic static load and constant axial force. Based on the experimental results, normalized trilinear skeleton curves were then put forward. Theoretical equation of normalizing point (ultimate strength point) was built up according to the load-bearing mechanism of RC columns and verified by the 5 specimens in this test and 14 SRC columns from parallel tests. Since no obvious strength deterioration and pinch effect were observed from the load-displacement curve, hysteresis rule considering only stiffness degradation was proposed through regression analysis. Compared with the experimental results, the applied analysis model is so reasonable to capture the overall cyclic response of SRC columns that it can be easily used in both static and dynamic analysis of the whole SRC structural systems.

study on pattern identification about fluid-humor of skin in Oriental Medicine (한방 피부 진액 변증론 연구)

  • Kim, Kyoung-Shin;Cho, Ga-Young;Kim, Duck-Hee;Kim, Byoung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.19 no.2
    • /
    • pp.35-42
    • /
    • 2011
  • The purpose of this study is to evaluate the difference about pathogenesis of skin type. the theory that explains each individual react to certain stress is generally accepted in traditional oriental medicine. The aim of this experiment is to find out relationship between the effect of facial condition and the vital conditions of traditional Oriental medicine. We recognized that pattern identification of fluid-humor could be divided into 4 different groups. The reason is that the fluid-humor could be interpreted as Qi & Blood, furthermore Qi & Blood were categorized into deficiency and excess groups. Korean female volunteers in good health participated in this experiment. Three doctors of Oriental medicine classified them into 4 groups based on qi-blood and deficiency-excess concept(qi-deficiency; qi-excess:qi-stagnation; blood-deficiency; blood-excess:static-blood). Volunteers were assessed with non-invasive skin measuring devices. And we analyzed the correlation of skin physiological parameters with vital conditions; moisture, sebum and elasticity. Measurement moisture and sebum of facial skin tended to deacease only in static blood group.

An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System (지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구)

  • Lim, Hyo-Jae;Kwon, Jeong-Tae;Kim, Chang-Eob;Kong, Hyoung-Jin;Park, Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

Analysis of the Dynamic Behavior of Guardrail Posts in Sloping Ground using LS-DYNA (LS-DYNA를 이용한 비탈면에 설치된 가드레일 지주의 동적거동)

  • LEE, Dong Woo;Woo, Kwang Sung
    • International Journal of Highway Engineering
    • /
    • v.19 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • PURPOSES : This paper presents a finite element model to accurately represent the soil-post interaction of single guardrail posts in sloping ground. In this study, the maximum lateral resistance of a guardrail post has been investigated under static and dynamic loadings, with respect given to several parameters including post shape, embedment depth, ground inclination, and embedment location of the steel post. METHODS : Because current analytical methods applied to horizontal ground, including Winkler's elastic spring model and the p-y curve method, cannot be directly applied to sloping ground, it is necessary to seek an alternative 3-D finite element model. For this purpose, a 3D FHWA soil model for road-base soils, as constructed using LS-DYNA, has been adopted to estimate the dynamic behavior of single guardrail posts using the pendulum drop test. RESULTS : For a laterally loaded guardrail post near slopes under static and dynamic loadings, the maximum lateral resistance of a guardrail post has been found to be reduced by approximately 12% and 13% relative to the static analysis and pendulum testing, respectively, due to the effects of ground inclination. CONCLUSIONS : It is expected that the proposed soil material model can be applied to guardrail systems installed near slopes.

Investigating the effect of bond slip on the seismic response of RC structures

  • Fallah, Mohammad Mehdi;Shooshtari, Ahmad;Ronagh, Hamid Reza
    • Structural Engineering and Mechanics
    • /
    • v.46 no.5
    • /
    • pp.695-711
    • /
    • 2013
  • It is reasonable to assume that reinforced concrete (RC) structures enter the nonlinear range of response during a severe ground motion. Numerical analysis to predict the behaviour therefore must allow for the presence of nonlinear deformations if an accurate estimate of seismic response is aimed. Among the factors contributing to inelastic deformations, the influence of the degradation of the bond slip phenomenon is important. Any rebar slip generates an additional rotation at the end regions of structural members which are not accounted for in a conventional analysis. Although these deformations could affect the seismic response of RC structures considerably, they are often neglected due to the unavailability of suitable models. In this paper, the seismic response of two types of RC structures, designed according to the Iranian concrete code (ABA) and the Iranian seismic code (2800), are evaluated using nonlinear dynamic and static analyses. The investigation is performed using nonlinear dynamic and static pushover analysis considering the deformations due to anchorage slip. The nonlinear analysis results confirm that bond slip significantly influences the seismic behavior of RC structure leading to an increase of lateral deformations by up to 30% depending on the height of building. The outcomes also identify important parameters affecting the extent of this influence.

Analysis of Propagating Crack Along Interface of Isotropic-Orthotropic Bimaterial by Photoelastic Experiment

  • Lee, K.H.;Shukla, A.;Parameswaran, V.;Chalivendra, V.;Hawong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.102-107
    • /
    • 2001
  • Interfacial cracks between an isotropic and orthotropic material, subjected to static far field tensile loading are analyzed using the technique of photoelasticity. The fracture parameters are extracted from the full-field isochromatic data and the same are compared with that obtained using boundary collocation method. Dynamic Photoelasticity combined with high-speed digital photography is employed for capturing the isochromatics in the case of propagating interfacial cracks. The normalized stress intensity factors for static crack is greater when $\alpha=90^{\circ}C$ (fibers perpendicular to the interface) than when $\alpha=0^{\circ}C$ (fiber parallel to the interface) and those when $\alpha=90^{\circ}C$ are similar to ones of isotropic material. The dynamic stress intensity factors for interfacial propagating crack are greater when $\alpha=0^{\circ}C$ than $\alpha=90^{\circ}C$. The relationship between complex dynamic stress intensity factor $|K_D|$ and crack speed C is similar to that for isotropic homogeneous materials, the rate of increase of energy release rate G or $|K_D|$ with crack speed is not as drastic as that reported for homogeneous materials.

  • PDF

Analysis of Accelerated Soft Error Rate for Characteristic Parameters on Static RAM (정적 RAM 특성 요소에 의한 소프트 에러율의 해석)

  • Gong, Myeong-Kook;Wang, Jin-Suk;Kim, Do-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.199-203
    • /
    • 2006
  • This paper presents an ASER (Accelerated Soft Error Rate) integral model. The model is based on the facts that the generated EHP/s(electron hole pairs) are diminished after some residual range of the incident alpha particle, where residual range is a function of the incident angle and the capping layer thickness over the semiconductor junction. The ASER is influenced by the flux of the alpha particles, the junction area ratio, the alpha particle incident angle when the critical charge is same as the collected charge, and the sizes of the alpha source and the chip. The model was examined with 8M static RAM samples. The measured ASER data showed good agreement with the calculated values using the model. The ASER decreased exponentially with respect to the operational voltage. As the capping layer thickness increases up to $16{\mu}m$, the ASER increases, and after that thickness, the ASER decreases. The ASER increased as the depth of BNW increased from $0{\mu}m\;to\;4{\mu}m$. and then saturated. The ASER decreased as the node capacitance increased from 2fF to 5fF.

Higher order static analysis of truncated conical sandwich panels with flexible cores

  • Fard, Keramat Malekzadeh
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1333-1354
    • /
    • 2015
  • A higher order analytical solution for static analysis of a truncated conical composite sandwich panel subjected to different loading conditions was presented in this paper which was based on a new improved higher order sandwich panel theory. Bending analysis of sandwich structures with flexible cores subjected to concentrated load, uniform distributed load on a patch, harmonic and uniform distributed loads on the top and/or bottom face sheet of the sandwich structure was also investigated. For the first time, bending analysis of truncated conical composite sandwich panels with flexible cores was performed. The governing equations were derived by principle of minimum potential energy. The first order shear deformation theory was used for the composite face sheets and for the core while assuming a polynomial description of the displacement fields. Also, the in-plane hoop stresses of the core were considered. In order to assure accuracy of the present formulations, convergence of the results was examined. Effects of types of boundary conditions, types of applied loads, conical angles and fiber angles on bending analysis of truncated conical composite sandwich panels were studied. As, there is no research on higher order bending analysis of conical sandwich panels with flexible cores, the results were validated by ABAQUS FE code. The present approach can be linked with the standard optimization programs and it can be used in the iteration process of the structural optimization. The proposed approach facilitates investigation of the effect of physical and geometrical parameters on the bending response of sandwich composite structures.

Analysis of HVDC Inverter and Application of Objective Functions for the Optimal Filter Design (직류송전 인버터의 필터 최적설계를 위한 해석 및 목적함수의 선정)

  • 오성철;정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.82-89
    • /
    • 2001
  • This paper proposes several methods to analyze dynamic and static characteristics of HVDC inverter system. The characteristic analysis is essential of the controller and filter design of the HVDC inverter system. Dynamic characteristic can be analyzed with EMTP simulation and static characteristic can be obtained by solving newly proposed load flow equation which includes the filter and load characteristic. New simple per-phase-equivalent circuit is also proposed. In this circuit, HVDC inverter is considered as a current source depending on the on-off status of switch. Dynamic and static characteristic can be analyzed by the proposed per-phase-equivalent circuit. For the optimal filter design, various performance criteria are proposed. The performance index, based on the per-phase-equivalent circuit, is calculated. Voltage harmonics and filter power loss are selected as criteria. Optimization procedure is explained to find optimal passive filter parameters.

  • PDF

Static and Dynamic Horizontal Earth Pressures against Vertical or Inclined Rigid Walls (연직 또는 경사진 강성벽체에 작용하는 정적 및 동적수평토압)

  • 김홍택
    • Geotechnical Engineering
    • /
    • v.6 no.2
    • /
    • pp.35-46
    • /
    • 1990
  • An analytical solution method is described to estimate the developed static and dynamic horizontal earth pressures behind a vertical or inclined rigid wall experiencing outward toranslational movement. The results predicted by the developed method of analysis are compared with chose from the experimental model testg on sandy. The comparisons show good agreements at various stases of wall movement. When the wall i9 inclined with a certain angle in the direction of the supported strand sass, the effects of reduction in developed static and dynamic horizontal earth pressures are also analyzed. Finally, results of analytical parametric study are presented to demonstrate the effects of various parameters, such as wall friction angle and internal strand friction angle.

  • PDF