• Title/Summary/Keyword: start current

Search Result 582, Processing Time 0.022 seconds

Quench propagation in resistive SFCL (저항형 초전도 한류기에서의 퀀치 전파)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.337-342
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters based on YB $a_{2}$/C $u_{3}$/ $O_{7}$ thin films and investigated their quench propagation characteristics. The YB $a_{2}$/C $u_{3}$/ $O_{7}$ films was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The quench was concluded to start locally and propagates until completed. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time depended strongly on potential fault current amplitude and not significantly on fault angle which indicates that the quench propagation speed is affected more by heat dissipation rate than by fault current increase rate. The quench completion time was 1 msec at the fault current of 65 $A_{peak/{\ak}}$.

  • PDF

A Study on Starting Algorithm of Large Synchronous Motor for Gas Turbine in Field-Weakening Region using SFC (SFC를 이용한 약계자 영역에서 가스터빈용 동기 전동기의 기동 알고리즘에 관한 연구)

  • Ryu, Ho-Seon;Lee, Joo-Hyun;Kang, Youn-Jong;Hwang, Seon-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.411-419
    • /
    • 2008
  • SFC(Static Frequence Converter)system has come to be used as start up drive system for large synchronous motor in many industry applications. Many papers have been presented the control algorithm for pumped storage power generation using SFC system but they did not included about start up algorithm of SFC system for gas turbine. This paper presents the field weakening control algorithm for a large synchronous motor using output signal of anti-windup in PI current regulator and the results of experiment show that the proposed algorithm is proper and effective.

A Comprehensive Performance Evaluation in Collaborative Filtering (협업필터링에서 포괄적 성능평가 모델)

  • Yu, Seok-Jong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.83-90
    • /
    • 2012
  • In e-commerce systems that deal with a large number of items, the function of personalized recommendation is essential. Collaborative filtering that is a successful recommendation algorithm, suffers from the sparsity, cold-start, and scalability restrictions. Additionally, this work raises a new flaw of the algorithm, inconsistent performance of recommendation. This is also not measurable by the current MAE-based evaluation that does not consider the deviation of prediction error, and furthermore is performed independently of precision and recall measurement. To evaluate the collaborative filtering comprehensively, this work proposes an extended evaluation model that includes the current criteria such as MAE, Precision, Recall, deviation, and applies it to cluster-based combined collaborative filtering.

Design of monolithic DC-DC Buck converter with on chip soft-start circuit (온칩 시동회로를 갖는 CMOS DC-DC 벅 변환기 설계)

  • Park, Seung-Chan;Lim, Dong-Kyun;Lee, Sang-Min;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7A
    • /
    • pp.568-573
    • /
    • 2009
  • This paper presents a step-down DC-DC converter with On-chip Compensation for battery-operated portable electronic devices which are designed in O.13um CMOS standard process. In an effort to decrease system volume, this paper proposes the on chip compensation circuit using capacitor multiplier method. Capacitor multiplier method can minimize error amplifier's compensation capacitor size by 10%. It allows the compensation block of DC-DC converter be easily integrated on a chip and occupy less layout area. But capacitor multiplier operation reduces DC-DC converter efficiency. As a result, this converter shows maximum efficiency over 87.2% for the output voltage of 1.2V (input voltage : 3.3V), maximum load current 500mA, and 25mA output ripple current. This voltage mode controled buck converter has 1MHz switching frequency.

Modified Current Differential Relay for $Y-{\Delta}$ Transformer Protection ($Y-{\Delta}$ 변압기 보호용 수정 전류차동 계전기)

  • Jin, En-Shu;Kang, Yong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.95-101
    • /
    • 2006
  • This paper proposes a modified current differential relay for $Y-{\Delta}$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation, because the exciting current was successfully compensated. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay does not require additional restraining signal and thus cause time delay of the relay.

A Stable Black-Start Strategy for a Stand-Alone DC Micro-Grid

  • Cha, Jae-Hun;Han, Yoon-Tak;Park, Kyung-Won;Oh, Jin-Hong;Choi, Tae-Seong;Ko, Jae-Hun;MAHIRANE, Philemon;An, Jae-Yun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.30-37
    • /
    • 2018
  • Unlike an AC system, a DC system does not cause problems with synchronization, stability, reactive power, system losses, and cost. However, more research is still required for the application of DC Systems. This paper proposes a stable black-start strategy for a stand-alone DC micro-grid, which consists of an energy storage system, photovoltaic generator, wind-turbine generator, diesel generator, and DC loads. The proposed method is very important for avoiding inrush current and transient overvoltage in the power system equipment during restoration after a blackout. PSCAD/EMTDC software was used to simulate, analyze, and verify the method, which was found to be stable and applicable for a stand-alone DC micro-grid.

Modified Current Differential Relay for Y-$\Delta$ Transformer Protection (Y-$\Delta$ 변압기 보호용 수정 전류차동 계전기)

  • Kang, Yong-Cheol;Jin, En-Shu;Lee, Byung-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.9-13
    • /
    • 2004
  • This paper proposes a modified current differential relay for Y-$\Delta$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. The relay correctly discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

  • PDF

A Modified Current Differential Relaying Algorithm for Transformer Protection Considered by a Remanent Flux (잔류자속을 고려한 변압기 보호용 수정 전류차동 계전방식)

  • Kang, Y.C.;Jin, E.S.;Won, S.H.;Lim, U.J.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.262-265
    • /
    • 2003
  • During magnetic inrush or over-excitation saturation of the core in a transformer draws a large exciting current. This can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. In order to cope with the remanent flux at the beginning. the start of saturation of the core is detected and the core flux at the instant is estimated by inserting the differential current into a magnetization curve. Then, this core flux value can be used to calculate the core flux. The proposed relay calculates the core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss current and the magnetizing current from the conventional differential current. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

  • PDF

The Starting System Implementation of SPIM with Detecting Main Winding Current (주권선 전류검출에 의한 단상유도전동기의 구동시스템 구현)

  • 최낙일;박수강;오금곤;백형래;임양수;오기진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.166-170
    • /
    • 1997
  • A Single phase induction motor is the predominant fractional horsepower power rated, extensively used in domestic and industrial application. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper, single phase induction motor input current was detected by a small current transformer and determined TRIAC gate signal by using op-amp analog circuit. The soft-start strategy is based on limited auxiliary current angle during starting period in the closed-loop control. The Simulation and experimental result show the motor's starting characteristics of the proposal starting system and are compared with centrifugal switch starting motor.

  • PDF

The current status of the development of pryostarters (파이로스타터 개발 현황)

  • Hong, Moon-Geun;Lee, Soo-Yong
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.204-209
    • /
    • 2010
  • The current status of the development of pyrostarters, which play a role as a turbo pump starter in liquid propellant propulsion systems by supplying pressurized gas to power turbines for engine start, has been introduced. Firstly, the development history is briefly summarized, and secondly the current technical status in core parts for the development of pryrostarters such as solid propellants, internal ballistics, rupture discs, and igniters are presented. The current technical achievements could make it feasible to fulfill the development requirements for pyrostarters.