5MW Class Gas Turbine Engine Test Cell (5MW급 발전용 가스터빈 엔진 성능시험 설비)

  • Nam, Sam-Sik;Song, Ju-Young;Kim, Sung-Hyun;Lee, Ki-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.339-342
    • /
    • 2010
  • Doosan Heavy Industries & Construction Co., Ltd. constructed a gas turbine engine test cell to verify operating characteristics and design parameters of 5MW class gas turbine engine for power generation under developing. Engine test cell was designed to satisfy critical requirements to scrutinize all performance parameters of the engine with safe and reliability in accordance with design specification. As the test cell developed can effectively reproduce engine operation conditions covering from start-up to maximum power condition, it can be utilized to make a continuing design improvement of the engine based on practical test data at full stretch. Moreover, it is expected to be serviceable to develop derivative engines and be utilized to put them into serial production and contribute to a competitiveness reenforcement as a gas turbine engine manufacturer.

  • PDF

Thermal Analysis for the GT-96 Membrane Type LNGC during the Cool-down Period (GT-96 멤브레인형 LNGC의 급냉기간에서의 열해석)

  • Lee, Jung-Hye;Choi, Hyun-Kue;Choi, Soon-Ho;Oh, Cheol;Kim, Myoung-Hwan;Kim, Kyung-Kun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1346-1351
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000 $m^3$ class GT-96 membrane type LNG carrier under IMO design condition. The cool-down is performed to cool the insulation wall and the natural gas in cargo tank for six hours to avoid the thermal shock at the start of loading of $-163^{\circ}C$ LNG. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls clown from $-40^{\circ}C$ to $-130^{\circ}C$ and the spraying rate for the insulation wall cooling increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the 1 st barrier and 1st insulation, which are among the insulation wall, especially in the top side of the insulation wall. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted.

  • PDF

Air Pollution prediction at Highway Tollgate by Using Real Time Traffic Volume (실시간 교통량을 이용한 고속도로 요금소 대기요염도 예측)

  • 박성규;김신도;이정주
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.134-140
    • /
    • 2000
  • The increase in traffic is a worldwide phenomenon. In Korea, it has been increased by 20% per annual in recent 1990’s and approximately 10 millions cars had been registered until 1997. This traffic could easily affect and contribute the local outdoor air quality(QAQ) concerned. The QAQ in highway in one of the examples and the subject in this study. The seoul tollgate located at the north-end of Keypngbu Highway was selected for the study. In case of highway tollgate, the local air pollution could be directly affected by the traffic to approach, wait and start the tollgate. Nitrogen dioxide (NO$_2$) concentration exceeded the EAQS(Environmental Air Quality Standards), but overall indoor air quality was a little better than the outdoor air quality. The measured TSP concentration was much higher than that of the EAQS. To apply a management to a air quality problem of Seoul tollgate, it was predicted air quality with traffic volume and weather condition. It was calculated NO$_2$ emission with traffic volume and predicted in and out of booth by CALINE3 at the Seoul tollgate. To make a comparison between measured and predicted concentration, the prediction was good. It was shown that NO$_2$ concentration was high in the morning at the from Seoul direction and in the evening at the to Seoul direction. it was thought that NO$_2$ concentration variation was reflected according to the traffic volume.

  • PDF

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

Basic Study on the Doin Gigong Exercise for the Reduction of Shoulder-arm Pain (견비통 완화 도인기공체조에 대한 기초적인 연구)

  • Kim Lee-Sun;Kim Gyeong-Cheol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.52-57
    • /
    • 2006
  • Gigong exercise is simple form's game for health care. Gigong exercise is the training method in mind and body, and it prevent or cure the disease by becoming larger the human's nature-healing power This syudy intends to identify the effective processing channel of the Doin Gigong Exercise for the reduction of shoulder-arm pain. The processing channel of the Doin Gigong Exercise for the reduction of shoulder-arm pain cinsist of warming, main, finishing exercise. The warming exercise start breathing and concentrate upon shoulder-arm exercise. The upper and lower sides join-hands exercise give help smoothly the Gi-circulation of human body in every direction. The finishing exercise consist of experience to Gi with the object of maintaining human comfortable condition. As mentioned above, the Doin Gigong exercise is effective intervention for the reduction of shoulder-arm pain.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Effect of Combined Traditional Acupuncture, Pharmacopuncture and Applied Kinesiology on Lumbar Diseases of Resident Patients

  • Lee, Sang-Ju;Ahn, Chang Beohm
    • Journal of Pharmacopuncture
    • /
    • v.22 no.3
    • /
    • pp.184-191
    • /
    • 2019
  • Objectives: Recently several Korean medical doctors have begun practicing applied kinesiology (AK). Although the efficacy of combining traditional acupuncture (TA) and pharmacopuncture (PP) on lumbar diseases such as lumbar spinal stenosis (LSS) and lumbar herniation of intervertebral disk (LHID) has been examined, the possible benefits of combining TA, PP and AK approaches have not been examined. Therefore the aim of this study was to develop effective treatment for lumbar disorders by combining TA, PP, and AK treatments. Methods: Twenty-four patients hospitalized at Samse Korean Traditional Medicine Hospital between March and September 2018 with L5 or S1 root radiculopathy associated with LSS and LHID were included in this study. They were treated for 10 days with TA, PP and AK approaches that included category block, manipulation and strain/counterstrain treatments. The primary outcomes were mainly assessed using Japanese Orthopedic Association lumbar scores (JOALS). JOALS were determined before the start of treatment as well as five and 10 days after treatment started. Results: The treatments improved the lumbar condition of the patients based on JOA pain score. Conclusion: The combined TA, PP and AK treatments were effective in treating spinal diseases of resident patients. Prospective, controlled, and relevant protocols using multimodal strategies to define the role of TA, PP and AK are needed.

Relationship between the Tropical Sea Surface Temperature Distribution and Initiation Timing of the Typhoon Season in the Northwestern Pacific (열대 해수면 온도 분포와 북서태평양 태풍의 계절적 활동 시작일 변동 사이의 관련성)

  • Kim, Donghee;Kim, Hyeong-Seog
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • This study examined the relationship between the initiation timing typhoon season in the Northwestern Pacific and the tropical sea surface temperature (SST) using a numerical simulation. The initiation timing of the typhoon season is closely associated with SSTs over the Indian Ocean (IO) and the eastern Pacific (EP) in the preceding winter and early-spring. The experiment based on the Weather and Research Forecast (WRF) model showed that the start date of the typhoon season is delayed for about one month when the SSTs over the IO and the EP increase in the preceding winter. The forced tropical SST pattern induces anticyclonic anomalies in the Northwestern Pacific, which is an unfavorable condition for typhoon development, and hence it could delay the initiation of the typhoon season.

A Comparative Study on the Injection Rate Characteristics of Conventional and F-T Synthetic Gasoline Under Various Fuel Temperatures (다양한 연료온도 조건에 있어서의 기존 가솔린과 F-T합성 가솔린의 분사율 특성 비교 연구)

  • Jihyun Son;Gyuhan Bae;Seoksu Moon
    • Journal of ILASS-Korea
    • /
    • v.28 no.3
    • /
    • pp.143-149
    • /
    • 2023
  • Amidst the drive towards carbon neutrality, interest in renewable synthetic e-fuels is rising rapidly. These fuels, generated through the synthesis of atmospheric carbon and green hydrogen, offer a sustainable solution, showing advantages like high energy density and compatibility with existing infrastructure. The physical properties of e-fuels can be different from those of conventional gasoline based on manufacturing methods, which requires investigations into how the physical properties of e-fuels affect the fuel injection characteristics. This study performs a comparative analysis between conventional and Fischer-Tropsch (F-T) synthetic gasoline (e-gasoline) across various fuel temperatures, including the cold start condition. The fuel properties of F-T synthetic and conventional gasoline are analyzed using a gas chromatography-mass spectrometry technique and the injection rates are measured using a Bosch-tube injection rate meter. The F-T synthetic gasoline exhibited higher density and kinematic viscosity, but lower vapor pressure compared to the conventional gasoline. Both fuels showed an increase in injection rate as the fuel temperature decreased. The F-T synthetic gasoline showed higher injection rates compared to conventional gasoline regardless of the fuel temperature.

Grinding Characteristics of Diamond Burs in Dentistry (치과용 다이아몬드 버의 연삭가공 특성)

  • Lee, Keun-Sang;Lim, Young-Ho;Kwon, Dong-Ho;Choi, Man-Yong;Kim, Kyo-Han;Choi, Young-Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.66-72
    • /
    • 1997
  • This paper aims at reviewing the possibility application over normal or abnormal, detection used by AE and the wear characteristics of grinding process. In this study, when diamond bur in dentistry with chosen grinding conditions were tuned at grinding. The variation of grinding resistance and AE signal is detected by the use of AE measuring system. The tests are carried out in accordance with diamond burs and workpiece: arcyl and bovine. According to the experiment results, the following can be expected: AE has the possibility to detect the state normality and abnormality. Hpwever, the grinding resistance measuring can find it difficult to detect it. It can be accurately excepted from AE occurrence pattern in contact start point of diamond bur and bovine, grinding condition and derailment point. It is known that AErms is well compatible with grinding resistance. According to the increase of the material removal rate, the specific energy of the diamond bur is inclined to dectease and the grinding resistance has a tendency to increase.

  • PDF