• Title/Summary/Keyword: standards for preventing disaster

Search Result 16, Processing Time 0.031 seconds

Article - 환기.방재측면에서의 초장대.대심도 터널에 관한 고찰

  • Lee, Hang
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.54
    • /
    • pp.41-55
    • /
    • 2011
  • The current railway projects under plan, design, or construction have been designed as 'very long and deep underground tunnel'. Therefore, it is reasonable that the standards for preventing disaster in such conditions should be intensified in order to avoid repeating the same failure which happened in Daegu subway disaster, Although we consent to the opinion that nothing can compete with human being's life, it is very difficult to protect the life from all of potential disasters perfectly in railway fields because the excessive standards can result in excess construction cost, which can bring about cancelation of the project itself eventually. Therefore optimized disaster design standard is required to negotiate the conflict between economical cost and social tolerance limitation simultaneously.

  • PDF

Preventing disaster system of the subaqueous tunnel under the Han river in the Bundang railway (분당선 한강 하저터널의 방재시스템)

  • Kim Yong-Il;Hwang Nak-Yeon;Yoon Young-Hoon;Jie Hong-Keun;Jang Sung-Wook;Kim Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.308-327
    • /
    • 2004
  • As use of tunnels and subways increase there also are accidents proportionate to it. Daegu Subway Station fire, Hongjimoon tunnel fire led people to be conscious of disaster protection and as a result, there is a trend to adopt standards for fire protection. Accordingly, this thesis is focused on investigating various fire and water protection related issues for subaqueous tunnel under Ran river. The thesis developed evacuation and disaster prevention plan as fire level increases and have identified the suitability of disaster prevention through evacuation and fire simulation, countermeasure of a water leakage during construction and operation considering the subaqueous tunnel. And we selected EPB shield TBM equipment considering the ground condition and effect of boring hole, and accomplished reasonable water protection design through setting goals using event-tree method, as well as examining model test of boring hole and flooding in heavy rain. Also included structured total system consist of water leakage sensing system, water protection gate, pumping system and fire protection system to respond systematically in emergency.

  • PDF

A Study on Sharing Safety Information of Children's Play Facilities based on GIS using Accident Analysis for Accident Prevention (어린이 놀이시설 안전사고분석을 통한 GIS기반 사고예방 안전정보 공유 방안)

  • Yoo, Byungtae;Lee, Sujin;Heo, Boyoung;Yoon, Jiwon;Park, Sosoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.113-121
    • /
    • 2014
  • Children's play facilities have changed over a decade from the traditional play facilities in the front yard to the new type of commercial play facilities which install more exciting and enjoyable facilities, such as Kids Park. The more diversified in the type of facilities, the more difficult in the safety management by the existing system. The 'Safety Management System of Children's Play Facilities' of MOSPA(Ministry of Security and Public Administration) has provided the safety information uni-directly by government sector to the private communities. Recently, multi-directional information sharing methods, such as community mapping are adopted actively in the social activities which have common purpose for making the better community by information sharing with government and private sector. On the purpose of citizen's participation for safe play facilities and preventing accidents, this study investigated the status of child accidents and safety standards, especially focused on the children's play facilities. And the way for sharing safety information among the communities with the GIS mapping skills is suggested in the respect of more easily monitoring and practically inputting the comments on the status of management of play facilities by real users based on their experiences. It is expected that more activities from the private sector would participate to the safety management of children's play facilities by realizing the suggested system.

An Assessment of Flooding Risk Using Flash Flood Index in North Korea - Focus on Imjin Basin - (돌발홍수 지수를 이용한 북한 홍수 위험도 평가 - 임진강 유역을 중심으로 -)

  • Kwak, Chang Jae;Choi, Woo Jung;Cho, Jae Woong
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.12
    • /
    • pp.1037-1049
    • /
    • 2015
  • The most of natural disasters that occur in North Korea are flood, typhoon and damage from heavy rain. The damage caused by those disasters since the mid-1990s is aggravating North Korea's economic difficulties every year. By recognizing the seriousness of the damages from the floods, the North Korean government has carried out the river maintenance, farmland restoration, land readjustment and afforestation projects since the last-1990s, but it has failed preventing the damages. In order to estimate the degree of flood risk regarding damage from chronic floods that occur inveterately in North Korea, this research conducted an additional simulation for rainfall-runoff analysis to reflect the characteristics of the ungauged area that make foreign countries hard to obtain the hydrological data and do not open the topographical data to public. In addition, this research estimates the degree of flood risk by selecting the factors of the hazard, exposure and vulnerability by following the standards of the Intergovernmental Panel on Climate Change (IPCC).

An Analysis on the Problems of the Serious Disaster Punishment Act from the Construction Industry's Perspective and Proposed Improvement Measures (건설업계 관점에서의 중대재해처벌법 시행에 따른 문제점 분석 및 개선방안)

  • Lee, Dae-Hyeong;Lee, Jun-Yong;Son, Chang-Baek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.187-196
    • /
    • 2023
  • The objective of this study was to analyze the awareness, necessity, and challenges of the Serious Disaster Punishment Act within the domestic construction industry, which is subject to the legislation implemented by the government. The research aimed to propose future improvement measures. According to the findings, safety officials consider securing more young and competent domestic skilled workers, as well as improving safety management standards and workers' safety awareness, to be the most crucial factors in preventing and reducing safety accidents. Furthermore, the primary improvement plan for the Serious Disaster Punishment Act involves clarifying ambiguous provisions in the current law. Government policy support is necessary to enhance the effectiveness of the Serious Disaster Punishment Act, and revisions should focus on preventive measures that contribute to the establishment of a safe working environment.

A Study on Human Factor for Port State Control System (항만국통제제도에 대한 인적요인 연구)

  • Lee, Yun-Cheol;Kim, Jin-Kwon;Jeon, Hae-Dong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.108-109
    • /
    • 2005
  • The aim of Port State Control(PSC) system is recognized as a proficient mechanism in preventing coastal traffic accident and protecting marine environment. Recently, PSC system is focused on human factor of International Maritime Convention, especially ILO and STCW Convention by considering many accidents resulted from human factor. Therefore, we have to understand of Consolidated Maritime Labour Convention which describes employment conditions and social welfare policy, the rights about the lowest wages, the overdue wages, the unemployment protection. a disaster reward, etc and STCW Convention which describes standards of training, certification and watchkeeping for seafarers. The aim of this study is to recognize inspection points about human factor of these Conventions. .

  • PDF

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

Improving the disease control ratings to manage livestock contagious animal disease in farms (가축 전염병 관리를 위한 농장 질병관리등급제 개선 방안)

  • Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.4
    • /
    • pp.267-271
    • /
    • 2020
  • The emergence of highly contagious viral diseases of livestock and poultry such as foot-and-mouth disease (FMD), African swine fever (ASF) and highly pathogenic influenza (HPAI) have necessitated the formulation of policies and regulatory frameworks for preventing ingress of exotic diseases and controlling dissemination of endemic diseases within the country. The disease control ratings to manage contagious livestock disease in farms have not being widely used because the evaluation parameters were not being considered inappropriate. The purpose of this study was to reinforce the validity of the parameters for evaluation factors and the objectivity of the scoring criteria in the application of the current disease management rating system. The diseases subject to intensive management were improved by reflecting farm situation. For the evaluation based on the disease grading system of farms, the diseases subject to intensive management were realized, the list of diseases for evaluating the vaccination rate was revised, and the quarantine and sanitation management standards were revised. The effectiveness of the improved livestock disease management system was confirmed through the application of actual pig farms. Therefore, this system will be used as a means to evaluation the biosecurity at the farm units. Through this, it will contribute to establish effective biosecurity measures for each farm by improving and supplementing the present disease grading system.

A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse (샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안)

  • An, Byung-Kug;Kim, Woon-Hyung;Yang, So-Jin;Ham, En-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.421-429
    • /
    • 2020
  • Purpose: The purpose of this study is to present step-by-step countermeasures to prevent fires in sandwich panel warehouses and to enhance on-site fire response capabilities. Method: Interviews of firefighters related to fire sites, advice from fire experts, and experiments on protection performance were conducted to draw up measures for each element to strengthen on-site response capabilities. Result: The fire safety management checklist for warehouse fire safety managers and the installation standards for wall protection of sandwich panel warehouses are presented. In addition, Standard Operational Procedures(SOP) for fire application of sandwich panel warehouses were established for firefighters on-site. Conclusion: Through this study, step-by-step fire safety measures were established for preventing, protecting and suppressing fires in sandwich panel warehouses.

Analysis of Electrical Equipment and Work Environment for Domestic Small-Scale Construction Site (국내 소규모 건설현장의 전기설비 및 작업환경 분석)

  • Kim, Doo-Hyun;Hwang, Dong-Kyu;Kim, Sung-Chul;Kang, Shin-Uk;Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.42-47
    • /
    • 2014
  • This paper is aimed to investigate and analyze of characteristic for electrical equipment and work environment for the small-scale site. In order to investigate and analyze electrical equipment and work environment for preventing electric shock disaster in construction sites, 50 small-scale construction sites and 12 large-scale construction sites are selected. This paper completed site investigations of low-voltage equipment and the portable electric machine and equipment in 12 large-scale construction sites and 50 small-scale construction sites. The findings were about the electric shock environment relevant to the ground-relevant equipment, the panel board, the protection tools, the sockets, the temporary wiring system, the portable and movable electric machines and equipments in small-scale construction sites. Finally, this study analyzed the domestic and foreign relevant standards and regulations and these findings can be utilized as educational data warning electric shock risk caused by electric equipment in small-scale construction site.