• Title/Summary/Keyword: standards for installation

Search Result 473, Processing Time 0.023 seconds

Improvement Plans of Railway standards for Surge Protective Devices used in Low-voltage Power circuits (저전압 전원용 서지보호장치 철도 규격의 개선방안)

  • 정용철;김언석;이재호;조봉관;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • In this paper we study the performance test items and improvement plans of surge protective devices for low-voltage power circuits used in railway system. Above of all, the sources of electromagnetic interference in railway system are researched. And then we compared domestic railway standard with IEC and IEEE standards far the test items and methodologies of surge protective devices. Through the investigations, we found that the domestic standard is behind in the number of test items and methods on surge protective devices. As the countermeasures, we suggest removing component tests of surge protective devices, separating standards for power and signal standards, and using international surge waveform. In applying to domestic railway surge protective devices, surge limiting voltage measuring and surge endurance tests by international standard methods are good result.

An Economic Analysis by Applying Extended Crime Prevention Standards for Buildings (건축물 범죄예방 기준 확대적용에 따른 경제성 분석)

  • Hyeon, Tae-Hwan;Cho, Young-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.53-60
    • /
    • 2019
  • Multi-unit house, multi-household house, row house and apartments with less than 500 households were included in the list of anti-crime for buildings following the revision of the "notice of crime prevention building standards" on July 31, 2019. Strengthening the performance of crime prevention buildings is inevitable to increase the cost of building construction, including installation of preventive facilities and use of facilities that have secured performance. Thus an economic analysis on the costs and expected benefits of implementing the standards is required for social consensus. Economic analysis is divided into cost analysis and benefit analysis. This study aims to perform an economic analysis on the installation of crime prevention facilities in the buildings subject to expanded crime prevention obligations. Cost analysis is calculated as the sum of the cost of installation and the price of the crime prevention facilities installed for each target residential building. Benefit analysis is calculated as the social cost of targeted crimes that are expected to decrease due to the installation of crime prevention facilities. Economic analysis shows that the total cost of installing crime prevention facilities in residential buildings is estimated at 107.31 billion won per year, while the total benefit from enhanced crime prevention performance is estimated at 9.38 billion won per year. Considering inflation, benefits are expected to outpace costs in the 28th year since the system was implemented.

Impermeable Standards for the Concrete Bottom of Dikes for Crude Oil Storage Tanks (원유저장탱크 방류벽의 콘크리트 바닥재 불침투성 세부기준 연구)

  • Shin, Changhyun;Park, Jai Hak;Yoon, Junheon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.54-60
    • /
    • 2016
  • The bottom of dikes must be kept impermeable to control hazardous chemicals spilled from storage tanks. Currently, insufficient related chemical control laws lead to a possibility to spread through the bottom. Generally, due to the high cost of installation and periodical maintenance, many businesses prefer to install the bottom with general concrete. But, since the impermeability of concrete is dependent on the kind of materials and chemical reaction, all concrete cannot be considered as impermeable material. Thus, it is necessary to make the installation standards of the dike bottom clear in order to avoid the argument over the impermeability and prevent the chemical accident. This study has suggested the standards of impermeable concrete by conducting 7-day exposure test to crude oil with the pilot dikes. The results have showed that the standards have the better impermeable performance compared with the germany standard, which have been penetrated at the maximum penetration depth of 1.9 cm. This study is expected to contribute to both the risk reduction of penetrating into the bottom and the cost reduction of spending to make the bottom of dikes impermeable.

Study on the Necessity and Specific Recommendations for Enhancing the Legal Requirements for Underwater Recreational Vessel Propeller Guards (수중레저선박 스크류망 제도개선의 필요성과 구체적인 제안)

  • Jung-Soo Lee;Jeong-Tack Min;Ho-Yun Jang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.226-232
    • /
    • 2024
  • During scuba diving in Korea, accidents involving bodies being struck by the ship propeller when entering and exiting the water, repeatedly occur every year. In response to the need to reduce accidents and implement safety management measures, Korea has established regulations for the installation and management of propeller guards. However, owing to the absence of clear production regulations in domestic laws and regulations, the installation standards are ambiguous, and the inspection items are limited to the appearance and fixation status. As a result, the safety of divers in propeller accidents is not guaranteed. Therefore, this study was conducted to specify the current legal requirements for the installation and inspection of propeller guards. To achieve this goal, we conducted a thorough analysis of the current state of domestic and foreign propeller guards and the legal factors pertaining to safety standards. Based on this analysis, we identified specific areas for improvement and proposed a plan to enhance the system for installation and inspection. The installation standards for propeller guards were clearly outlined in terms of the lattice size and material. Additionally, inspection standards were proposed for appearance, fixation, and material condition, along with clear indicators for assessing them.

Comparison and Analysis of Domestic and Foreign Standard for Solely Environment Installation of Power Station (수·변전설비의 안전 환경 설치에 관한 국내외 규정 비교 분석)

  • Bae, Seok-Myung;Kim, Han-Sang;Bang, Sun-Bae;Lee, Kun-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.45-53
    • /
    • 2005
  • It's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, in this paper we compared domestic and foreign standard on safety environment of power station. From this, we draw several questions in case of installation on power station and we proposed a draft of relative standard to apply in power station.

Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

A Survey on the Standards of EES (Electrical Energy Storage) Systems (전기에너지 저장 시스템 국제 표준화 동향)

  • Jeong, S.;An, Y.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.2
    • /
    • pp.101-109
    • /
    • 2019
  • Electrical energy storage (EES) systems store generated electricity in energy storage devices such as batteries and discharge the stored energy when necessary. Individual subsystems of the EES system are being standardized independently; however, a holistic understanding of the whole system is necessary because the EES system is large and complex. IEC TC 120 has developed international standards of EES systems. In this paper, EES systems standards in IEC TC 120, including the planning and installation of EES systems, are presented. Further, ongoing standardization for the application of EES systems to backup power and emergency support is described.

A Trend of the National and International Standards for Fluorescent Induction Lamps (무전극 형광램프 국내외 표준화 동향)

  • Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Lee, D.Y.;Yang, S.Y.;Ham, J.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.145-147
    • /
    • 2007
  • Fluorescent induction lamps are assembly of a Low Pressure Mercury discharge vessel and an inductive power coupler. A vessel containing at least a Low Pressure Mercury vapor, which will be energized by means of the Inductive Coupler. The Ultra Violet radiation from the resulting discharge is converted by a layer of fluorescent material into visible light. The discharge vessel may have means of mechanical fixation to position it to the Inductive power coupler. The component to transform High Frequency electrical energy, by means of induction, in order to energize the Low Pressure Mercury in the discharge vessel. The component includes electrical connection. Fluorescent induction lamps don't have international standards yet. So we try to correspond Korea standards to international standards.

  • PDF

A Study on the Improvement Plan of Construction Noise Monitoring (공사장 소음모니터링 개선방안에 관한 연구)

  • Park, Young-Min;Kim, Kyoung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1056-1065
    • /
    • 2013
  • Noise generated from Construction site has been raised most civil complaints to 64.4 % among the environmental pollution in 2011. Therefore, local government recommends and prescribes that construction sites over a certain scale install sound level meter for noise monitoring. For example, Seoul has implemented a 24 hour noise monitoring system, with real time communication, to the large construction sites more than 10,000 $m^2$ from the end of August 2012. But it is difficult to use noise measurement data for the construction noise assessment, since the installation standards and technical specifications for construction noise monitoring system are not presented. In this paper, we proposed noise monitoring system improvement plan including technical specifications and installation standards using the investigating results of the problems of current noise monitoring system and the foreign cases.