• Title/Summary/Keyword: standards for installation

Search Result 473, Processing Time 0.022 seconds

PC말뚝 이음시공용 강관이음부의 적정규격 결정에 관한 연구

  • 임종석;한찬균
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.03a
    • /
    • pp.103-114
    • /
    • 1992
  • The jointing method of PC pile installation, which utilizes steel sleeve, is most popular for the deep bearing stratum( deeper than 15m ) or the irregular bearing stratum depths. However, this method has some difficulties in safety because there is no optimum standards of steel sleeve. This research attempts to determine the optimum standard of steel sleeve for 350mm PC pile, which is most widely used, through bending moment test designated by KS and numerical analysis using finite element method. According to the results, the optimum length of steel sleeve is three times longer than diameter of pile, and the thickness of steel sleeve is more than 2.5mm.

  • PDF

Development of Optimal Operation Algorithm about CES Power Plant (CES 발전소의 최적운용 알고리즘 개발)

  • Kim, Yong-Ha;Park, Hwa-Yong;Kim, Eui-Gyeong;Woo, Sung-Min;Lee, Won-Ku
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • Recently due to the increasing of the importance on the green energy is getting higher by implementing EERS(Energy Efficiency Resource Standards) and NA(Negotiated Agreement) such as lacks of natural resources and The United Nations Framework Convention on Climate Change. And the most practical solution is CHP(Combined Heat and Power) which performs the best energy efficiency. This paper developed optimal operation mechanism of CES(Community Energy System) for enhancement of energy efficiency using CHP(Combined Heat and Power), PLB(Peak Load Boiler) and ACC(ACCumulator) capacities. This method optimally operated these capacities calculated the maximum profits by Dynamic Programing. Through the case studies, it is verified that the proposed algorithm of can evaluate availability.

A Study On XML Based Open Service Platform For Demand-Side Resource Management (XML 기반의 수요자원 관리 개방형 서비스 플랫폼에 관한 연구)

  • Yoon, Jae-Weon;Um, Dae-Jin;Choi, Jung-In;Lee, Ingyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.43-48
    • /
    • 2014
  • With the energy paradigm shift from supply side management to demand side management, many researches have been done on demand side resource management and demand response. At the same time, Obix, BacNet-WS and OPC-UA are popularly used in buildings and industry energy management system. However, it is not easy to interchange the data and information among the systems cause a variety of protocols are used in buildings and factories. Therefore, in this paper, we are proposing an open business platform not only to integrate and manage the demand resources using various protocols and standards, but also to allow to plug-ins a new business service on top of the platform.

Grid-Connected Photovoltaic System Applying the Step Variable MPPT Control and DVR (Step 가변형 MPPT 제어기법과 DVR을 적용한 계통연계형 태양광 발전 시스템)

  • Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.42-49
    • /
    • 2012
  • Grid-connected photovoltaic generator system requires high performance PCS(Power Conditioning System) according to the standard of 'Distributed Generation Grid-Connected Technology Standards'. This paper presents the MPPT control method which improves output efficiency through fast tracking to the maximum power point of PV and a reduced self-excited vibration. Secondly, in this paper DVR function was applied to PCS to compensate the voltage sag frequently happening for a power system. The proposed PCS control is analyzed and compared to conventional PCS operating characteristic, the various insolation and loads, and voltage sag condition through PSIM tool. It proves the utility.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

A Study on the Functional Characteristics of White LED by Prototype Products (시제품 조사를 통한 백색 LED의 기능적 특성에 관한 연구)

  • Chang, Jun-Ho;Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.105-108
    • /
    • 2007
  • Because of energy efficiency and environment-friendly characteristics, demands of white LED are being increased in various fields. White LED is being observed as next-generation light sources to alternate incandescent and fluorescent lamps so that the studies on white LED are being processed continuously. This study investigates technical developments and market movements of white LED to evaluate technical characteristics and to analyze performances data by comparing prototypes of white LEDs. And comparing efficiency of white LED with that of incandescent and fluorescent lamps, this study aimed at presentation of compatible standards for future LEDs.

  • PDF

Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin (히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발)

  • Hong, Seok-Gi;Jeong, Hee-Suk;Ryeom, Jeong-duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

An examination on proper voltage operation standard for 154kV power system through demand analysis (수요분석을 통한 154kV 계통전압 유지기준 설정)

  • Lee, Ik-Jong;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.428-431
    • /
    • 2009
  • KPX sets up the voltage standards according to the voltage level to supply a good quality of electricity to customers. Supply voltages are divided into 4 levels - 345kV, 154kV, 22.9kV, and distribution voltage consisting of 110, 220 and 380V. In this research, we examine the optimal voltage operating level focused on 154kV system that mostly affects electricity quality, through analysing the system demand.

  • PDF

Analysis of Quality Audit Points by the comparison of ISO/CD 9000-3 : 1995 and ISO 9001 : Quality System - Life Cycle Activities (ISO/CD 9000-3:1995와 ISO 9001의 비교를 통한 품질감사 점검사항 분석 :품질시스뎀 -생명주기 활동을 중심으로)

  • 이종무
    • Journal of the Korea Society of Computer and Information
    • /
    • v.1 no.1
    • /
    • pp.65-82
    • /
    • 1996
  • The assurance of software product. which Is different to other products. is very complex because of Its characteristics. The use of objective development standards or guidelines and the confirmation to meet user's requirements are Important to achieve the software quality system. Moreover correct understanding of qualitv standards and continuous applications of check-points for qualify audit are necessary. ISO 9000 series. which are International standards. were made for the qualify assurance. Among them. ISO 9000-3 is the quality management and quality assurance standards for applying ISO 9001 to the design. development. supply. installation and maintenance of software. The newly revised ISO/CD 9000-3:1995 contains a lot of enforced changes within ISO 9001 framework - quality standards for manufactured products. This paper analyses the revised ISO 9000-3 by comparing it to ISO 9001. and derives quality audit points to use for qualify audit In future.

  • PDF

Comparison and Analysis of Domestic and Foreign Standard for safety environment installation of power station (수.변전설비의 안전 환경 설치에 관한 국내외 규정 비교 분석)

  • Bai, Seok-Myeong;Kim, H.S.;Bang, S.B.;Kim, K.H.;Lee, K.H.;Kim, J.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.267-273
    • /
    • 2004
  • It's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, we studied on the safety environment in power station and compared of internal and external standards. So this paper gives information which is applied to install the electrical facilities and prevents measures against electrical accidents.

  • PDF