• 제목/요약/키워드: standard tension test

검색결과 97건 처리시간 0.024초

열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해 (Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test)

  • 이호진;김만원;이봉상
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.62-67
    • /
    • 2005
  • An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화 (Change of Strength of High-Strength Bolted Connection Depending on Standard and Over Bolt Hole)

  • 양승현
    • 한국강구조학회 논문집
    • /
    • 제24권5호
    • /
    • pp.605-612
    • /
    • 2012
  • 표준공으로 고장력볼트를 체결한 인장부재는 구조내력은 증가하지만 시공성이나 경제성 측면에서 문제점을 야기시키게 된다. 본 연구에서는 인장부재의 고장력볼트 체결부를 표준공 및 과대공으로 하는 총 28개의 시험편을 제작하여 인장시험을 실시하였다. 시험결과로부터 얻어진 표준공 및 과대공 시험편의 인장하중을 순단면 및 연단거리에 의한 설계강도와 비교하여 연결부의 강도변화를 확인하였다. 과대공으로 제작된 시험편의 인장하중은 표준공으로 제작된 시험편의 인장하중보다 감소하였으나, 현행 설계기준의 설계강도를 상회하였으며 과대공으로 인하여 다소의 강도저하는 부득이하지만 안전성을 만족하였다.

이동경화 모델에 기반한 MS1470 강판의 스프링백 예측 (Spring-back Prediction of MS1470 Steel Sheets Based on a Non-linear Kinematic Hardening Model)

  • 박상천;박태준;고영우;석동윤;;;정관수
    • 소성∙가공
    • /
    • 제22권6호
    • /
    • pp.303-309
    • /
    • 2013
  • Spring-back of MS1470 steel sheets was numerically predicted using a non-linear kinematic hardening material behavior based on the Yoshida-Uemori model. From uniaxial tension and uniaxial tension-compression-tension data as well as the uniaxial tension-unloading-tension data, the parameters of the Yoshida-Uemori model were obtained. For the numerical simulations, the Yoshida-Uemori model was implemented into the commercial finite element program, ABAQUS/Explicit and ABAQUS/Standard using the user-defined material subroutines. The model performance was validated against the measured spring-back from the benchmark problems of NUMISHEET 2008 and NUMISHEET 2011, the 2-D draw bending test and the S-rail forming test, respectively.

양생조건에 따른 폴리머 시멘트 모르타르의 인장접착강도 (Adhesion in Tension of Polymer-Modified Mortars according to Curing Conditions)

  • 조영국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.200-201
    • /
    • 2018
  • The purpose of this study is to evaluate the adhesion in tension of polymer-modified mortars according to curing conditions. From the test results, the adhesion in tension is seriously affected by type of curing conditions compared with type of polymer dispersions or polymer-cement ratios. The maximum adhesion in tension of EVA-modified mortar with polymer-cement ratio of 20% cured by standard condition is about 1.81 times, the cement mortar cured in water. It is apparent that the adhesion in tension of polymer-modified mortars according to raising of polymer-cement ratio is also much more improved irrespective of type of polymer dispersions and curing conditions.

  • PDF

Material modeling of steel fiber reinforced concrete

  • Thomee, B.;Schikora, K.;Bletzinger, K.U.
    • Computers and Concrete
    • /
    • 제3권4호
    • /
    • pp.197-212
    • /
    • 2006
  • Modeling of physically non-linear behavior becomes more and more important for the analysis of SFRC structures in practical applications. From this point of view we will present an effective, three-dimensional constitutive model for SFRC, that is also easy to implement in commercial finite element programs. Additionally, the finite element analysis should only require standard material parameters which can be gained easily from conventional experiments or which are specified in appropriate building codes. Another important point is attaining the material parameters from experimental data. The procedures to determine the material parameters proposed in appropriate codes seem to be only approximations and are unsuitable for precise structural analysis. Therefore a finite element analysis of the test itself is used to get the material parameters. This process is also denoted as inverse analysis. The efficiency of the proposed constitutive model is demonstrated on the basis of numerical examples and their comparison to experimental results. In the framework of material parameter identification the idea of a new, indirect tension testing procedure, the "Modified Tension Test", is adopted and extended to an easy-to-carry-out tension test for steel fiber reinforced concrete specimens.

파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구 (Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

흰 광폭평판 시험을 이용한 원자력 배관의 파괴거동예측 (Prediction of Failure Behavior for Nuclear Piping Using Curved Wide-Plate Test)

  • 허남수;김윤재;최재붕;김영진;임혁순;정대율
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.352-361
    • /
    • 2004
  • One important element of the Leak-Before-Break analysis of nuclear piping is how to determine relevant fracture toughness (or the J-resistance curve) for nonlinear fracture mechanics analysis. The practice to use fracture toughness from a standard C(T) specimen is known to often give conservative estimates of toughness. To improve the accuracy, this paper proposes a new method to determine fracture toughness using a nonstandard testing specimen, curved wide-plate in tension. To show validity of the proposed curved wide-plate test, the J-resistance curve from the full-scale pipe test is compared with that from the curved wide-plate test and that from the C(T) specimen. It is shown that the J-resistance curve form the curved wide-plate tension test is similar to, but that from the C(T) specimen is lower than, the J-resistance curve from the full-scale pipe test. Further validation is performed by investigating crack-tip constraint conditions via detailed 3-D FE analyses, which shows that the crack-tip constraint condition in the curved wide-plate tension specimen is indeed similar to that in the full-scale pipe under bending.

강섬유보강 모르타르 바름에 의한 콘크리트 조적 프리즘의 압축 및 사인장 강도 증진 효과 (Enhancement of Compressive and Shear Strength for Concrete Masonry Prisms with Steel Fiber-Reinforced Mortar Overlay)

  • 유지훈;명성진;박지훈
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.21-32
    • /
    • 2021
  • Concrete masonry prisms are strengthened with steel fiber-reinforced mortar (SFRM) overlay and tested for compressive and diagonal tension strength. Masonry prisms are produced in poor condition considering standard workmanship for masonry buildings in Korea. Amorphous steel fibers are adopted for SFRM, and appropriate mixing ratios of SFRM are derived considering constructability and strength. Masonry prisms are strengthened with different fiber volume ratios, while numerous strengthened faces and additional reinforcing meshes are produced for compression and diagonal tension tests. Compression and diagonal tension strength are increased by up to 122% and 856%, respectively, and the enhancement effect for diagonal tension strength was superior compared to compression strength. Finally, the test results and strength prediction equations based on existing literature and regression analysis are compared.

Determination of Double-K Fracture Parameters of Concrete Using Split-Tension Cube: A Revised Procedure

  • Pandey, Shashi Ranjan;Kumar, Shailendra;Srivastava, A.K.L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.163-175
    • /
    • 2016
  • This paper presents a revised procedure for computation of double-K fracture parameters of concrete split-tension cube specimen using weight function of the centrally cracked plate of finite strip with a finite width. This is an improvement over the previous work of the authors in which the determination of double-K fracture parameters of concrete for split-tension cube test using weight function of the centrally cracked plate of infinite strip with a finite width was presented. In a recent research, it was pointed out that there are great differences between a finite strip and an infinite strip regarding their weight function and the solution of infinite strip can be utilized in the split-tension specimens when the notch size is very small. In the present work, improved version of LEFM formulas for stress intensity factor, crack mouth opening displacement and crack opening displacement profile presented in the recent research work are incorporated. The results of the double-K fracture parameters obtained using revised procedure and the previous work of the authors is compared. The double-K fracture parameters of split-tension cube specimen are also compared with those obtained for standard three point bend test specimen. The input data required for determining double-K fracture parameters for both the specimen geometries for laboratory size specimens are obtained using well known version of the Fictitious Crack Model.

크기효과가 고려된 철근콘크리트 휨 부재의 최소철근비 제안 (A Proposal of Minimum Steel Ratio Considering Size Effect for Flexural Reinforced Concrete Member)

  • 유성원;허윤
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.128-136
    • /
    • 2010
  • In according with concrete structural design standard, it is common designing flexure reinforcement concrete to induce tension failure. So reinforcing ratio is limited to inducing tension failure. And maximum reinforcing ratio is regulated to protecting concrete compression strength caused by over reinforced building. Minimum reinforcing ratio is also limited in designing standard to protecting brittle failure as extremely using less reinforcing bar. But in minimum reinforcing ratio it is extremely conservative or it is sometimes impossible to induce stable tension-failure because they are depending on yield failure and experienced method and concrete designing standard strength. Therefore the purpose of the present paper is to evaluate the flexural behavior of minimum steel ratio of reinforced concrete of beams and to propose the guide-line of equation of minimum steel ratio by performing static flexural test of 16 beams according to size effect, number of steel, yielding stress of steel, and concrete compressive strength which are presumed effective variables. From experimental results, the equation of minimum steel ratio was newly proposed considered size effect.