Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test

열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해

  • Lee, Ho-Jin (Division of Nuclear Material Technology Development, Korea Atomic Energy Research Institute) ;
  • Kim, Maan-Won (Division of Nuclear Material Technology Development, Korea Atomic Energy Research Institute) ;
  • Lee, Bong-Sang (Division of Nuclear Material Technology Development, Korea Atomic Energy Research Institute)
  • 이호진 (한국원자력연구소 원자력재료기술개발부) ;
  • 김만원 (한국원자력연구소 원자력재료기술개발부) ;
  • 이봉상 (한국원자력연구소 원자력재료기술개발부)
  • Published : 2005.03.01

Abstract

An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

Keywords

References

  1. Standard test method for measurement of fatigue crack growth rates, ASTM E647-00, Annual Book of ASTM Standards, American Society for Testing and Materials, Philadelphia, PA, U.S.A., 2000
  2. D. E. Richardson and J. G. Goree, 'Experimental verification of a new two-parameter fracture model', ASTM STP 1189, pp. 738-750, 1993
  3. R. S. Piascik, and J. C. Newman, Jr., 'An extended compact tension specimen for fatigue crack growth and fracture testing,' Int. J. of Fracture, Vol. 76, R43-R48, 1996 https://doi.org/10.1007/BF00048293
  4. R. S. Piascik and S. A. Willard, 'The growth of small corrosion fatigue cracks in alloy 2404', Fatigue Fract. Engng. Mater. Struct., Vol. 17, No. 11, pp. 1247-1259, 1994
  5. R. S. Piascik, J. C. Newman, Jr. and J. H. Underwood, 'The extended compact tension specimen', Fatigue Fract. Engng. Mater. Struct., Vol. 20, No. 4, pp. 559-563, 1997 https://doi.org/10.1111/j.1460-2695.1997.tb00287.x
  6. R. John, 'Stress intensity factor and compliance solution for eccentrically loaded single edge cracked geometry,' Enging. Fract. Mech., Vol. 58, No. 112, pp. 87-96, 1997 https://doi.org/10.1016/S0013-7944(97)00070-2
  7. A. Saxena and S. J. Hudak, Jr., 'Review and extension of compliance information for common crack growth specimens', Int. J. of Fracture, Vol. 14, No. 5, pp. 453-468, 1978 https://doi.org/10.1007/BF01390468