• Title/Summary/Keyword: standard Korean

Search Result 34,727, Processing Time 0.062 seconds

A Study on The Software Coding Standard for Safety of Railway Embedded System (철도내장형제어기의 안전확보를 위한 소프트웨어 코딩규약 확보방안)

  • Shin, Kyung-Ho;Joung, Eui-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.193-195
    • /
    • 2008
  • Safety is important factor in railway system. Now most of the electric and electronic system which is applied in railway system is the embedded system which software is used. The constitution rate of software which is involved in railway system is gradually increasing. Most of the software which is used in railway system is implemented by the software developer. Thus the implemented code has different features according to the developer and this may cause the bad effect on the software's maintenance. International standard IEC 62279 requires an adoption the coding standard to developing the railway software. And it is plan to recommend complying with the coding standard in safety criteria for railway software which is noticed as the regulation of the Korean railway safety law. In this paper, we review the requirement of coding standards which is present in the software criteria for railway software and international standard. Also it investigates the coding standard which is in other safety related industry and presents the effective way to apply the software coding standard to domestic railway industry.

  • PDF

Uncertainty Analysis of Cross-Correlation Algorithm based on FFT by PIV Standard Images (표준 영상에 의한 FFT 기반 상호상관 PIV 알고리즘의 불확도 해석)

  • Lee, Suk-Jong;Choi, Jung-Geun;Sung, Jae-Young;Hwang, Tae-Gyu;Doh, Deog-Hee
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • Uncertainty introduced by a cross-correlation algorithm based on FFT has been investigated using PIV standard images. The standard images were generated by the Monte Carlo simulation method. Both bias and random errors from the velocity vector have been analyzed with regard to the particle diameter, displacement, and the number of particles. The uncertainty of velocity is evaluated based upon the IS0/IEC standard. As a result, a total error of $0.26\%$ is included in the PIV cross-correlation algorithm. In addition, the uncertainty budget is presented, where the effect of the above three variables is examined. According to the budget, the variation of the number of particles within the interrogation window mainly contributes to the combined standard uncertainty of the real measured velocity field when excluding the effect of errors by the experiments itself. Finally, the expanded uncertainty is found to be about $12\%$ at the $95\%$ confidence level.

  • PDF

A COMPARATIVE STUDY ON THE STANDARD AND INDIVIDUALLY CORRECTED RADIOGRAPHS IN TMJ TRANSCRANIAL RADIOGRAPHY (측사위 경두개 촬영시 표준사진과 개인별 수정사진의 비교연구)

  • Jung, Kyung-Yong;Lee, Ky-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.405-414
    • /
    • 1993
  • Among the radiographs for temporomandibular joint, transcranial radiograph is widely used for screening and diagnosing temporomandibular disorder because it has sharp image and it is easy to take. This study was performed to compare condylar position and image sharpness in standard and individually corrected transcranial radiographs using Accurad-200 headholder. Submentovertex view, Reverse-Towne view, Standard and individually corrected transcranial radiographs of 45 university students who were randomly selected were traced, measured and analyzed. The results were as follows : 1. The means of condylar axes and lateral slopes were $16.8^{\circ}\;and\;22.5^{\circ}$ respectively. There were no differences between male and female or right and left side. 2. Individually corrected radiographs showed smaller posterior joint ,space and larger anterior joint space than standard radiographs, but superior joint space did net show a statistical difference between standard and individually corrected radiographs. 3. While a large number$(42.2\%)$ of the standard radiographs showed concentric condylar position, lots of(57.8) condylar positions were retropositioned in the individually corrected radiographs. 4. The image sharpness was inferior in the individually corrected radiographs to that of the standard radiographs.

  • PDF

The Practical Use of Un Standard Message for cargo flow EDI (물류EDI 표준메세지 이용 방안)

  • 박남규;이태우
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.2
    • /
    • pp.57-73
    • /
    • 1993
  • Subject : The Practical Use of UN Standard Message for cargo flow EDI Writer : Park, Nam Kyu and Lee, Tae Woo It's necessary to prepare standard message which is agreed on among trading partners for EDI in container transport industry. Now KMPA is carrying out the EDI Project for establishing Korea Logistics Network. It is important to make standard message of documents using in transport industry to succesfully accomodate EDI. The objective of this study is to find out the method of UN standard message utility in Korea. For this study, the UN message guideline is primarily reviewed, and the process that Shipping Request being used in Hanjin Shipping Co. Ltd. is applied to UNSMs as case study. Generally the data format of EDIFACT is so complex and broad for inter-industry standard that the abstract of data format is usually used. Therefore, it is necessary to make the subset of standard message for Shipping Request in ocean industry. In the result of this study, that the ocean industry can use the subset of IFTMBF for Shipping Request is proved, and the subset is suggested. This thesis will contribute toward showing the practical way of standardrization of 350 documents using in trade, customs and transport sectors.

  • PDF

The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea. (국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책)

  • 오창환;유연희;이평구;박성원;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.298-301
    • /
    • 2000
  • Heavy metals are extracted from stream sediments, roadside soils and sediments and soils and tailings from mining area using partial extraction, acid digestion and HF-digestion. Compared to amounts of heavy metals extracted using partial extraction, those extracted using acid digestion are higher by 2.0∼220.9 times in Cu, 2.4∼2806.1 times in Pb, 1.3∼121 times in Cd, 14.1∼1300885 times in Fe, 1.2∼271.5 times in Mn, 1.3∼372.5 times in Zn, 2.2∼1734.5 times in Cr. Although partial extraction, which extracts less amounts of heavy metals from soil compared to acid digestion, is used in domestic standard method for examination of soil, domestic soil standard for heavy metals in non-agricultural and industrial areas is higher than soil standard in foreign countries which use acid digestion, For improvement of the domestic standard method for assessment of soil, it is suggested to lower the domestic soil standard for heavy metals or to change pretreatment method for extracting heavy metals from partial extraction to acid digestion with modifying the soil standard.

  • PDF

Factors Influencing Compliance with Standard Precautions in Intensive Care Unit and Emergency Room Nurses (중환자실과 응급실 간호사의 표준주의 수행에 영향을 미치는 요인)

  • Lee, Kyung-Ah;Kim, Hwa-Soon;Lee, Young-Whee;Ham, Ok-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.19 no.3
    • /
    • pp.302-312
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the level of knowledge, attitude and compliance with standard precautions and to identify predicting factors of compliance with standard precautions in ICU and ER nurses. Methods: The participants were 228 ICU and ER nurses working in one of three university hospitals and one general hospital. Collected data included general characteristics, features related to infection risk, and knowledge, attitude and compliance with standard precautions. For the final analysis, 218 questionnaires were used. Results: Within the previous one year, 103 (47.3%) nurses experienced pricking injury from syringe needles or other sharp materials, 111 (50.9%) nurses reported exposure to patients' blood and body fluid. In general, the scores for knowledge, attitude and compliance were all high. Compliance scores for nurses in intensive care units were significantly higher than those of nurses in emergency. There were significant correlations of knowledge, attitude, and compliance with standard precautions. Attitude and work place were significant factors predicting compliance with standard precautions. Conclusion: The results indicate that to increase nurse's compliance with standard precautions, continuous efforts to enhance positive attitudes and at the same time, improve work environments and use individualized approaches based on the work units are needed.

Factors Influencing Nursing Students' Performance on Standard Precautions of Infection Control (간호대학생의 병원감염예방 표준주의지침에 대한 수행도에 영향을 미치는 요인)

  • Seo, Ji Hye;Jung, Eun Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.19 no.2
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: The purpose of this study was to identify the factors that affect nursing students' performance on standard precaution of infection control. Methods: For the analysis of the study results, mistakes and percentages, descriptive statistics, Pearson's coefficient, and multiple regression analysis were performed. Results: Among the participants, 76.5% received hospital infection education, and 72.5% experienced an exposure to blood or body fluid, and the most of the exposures were occurred during the first semester of the third year. The knowledge score was $20.08{\pm}2.09$, the awareness score was $4.63{\pm}.41$, and the performance score was $4.34{\pm}.55$. In the relationship between the standard precautions knowledge, awareness, and performance, the awareness and the performance were in positive correlations, while the factors that affected the performance level of the standard precautions were awareness and the school year (third year), which had 37.0% of the total exposures. Conclusion: In order to increase the performance level of the standard precautions among the nursing department students, after identifying the differences between school years and demands of the students, it is necessary to provide continuous and regular education of standard precautions.

A study on the Assessment of Standard Wages for Constructing Luminaries for Landscope Lighting (경관조명기구의 설치에 대한 기준노임 산정에 관한 연구)

  • Yoo, Dong-Gil;Lee, Bok-Hee;Lee, Sok-Yeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.169-172
    • /
    • 2008
  • Recently, landscape lighting is more and more installing in many places such as park, cultural heritages, large-scale structures, bridges, apartment, and so on. However, there is no the government-set official estimation for standard wages constructing luminaries for landscape lighting. The cost of construction is estimated based on the standard wages of related-similar installations such as internal lighting fixtures or the designer's subjective decision. Sometimes, it is overestimated or underestimated. In this paper, the fundamental process for estimating the standard wages constructing luminaries for landscape lighting is studied. The estimation method of standard wages constructing lighting fixtures was examined on the basis of the type and capacities of luminaries, installation places, type and shapes of installation auxiliary materials, worker's skill, and etc. As a result, some results obtained in this work were significantly, different with the standard wages for internal electric wiring published by Korea Electric Association. In the future, to improve the accuracy of the estimation of the standard wages for constructing luminaries for landscope lighting, detailed factors related to the installation condition and dimensions and types of luminaries should be considered.

  • PDF

A Study of Power Conversion System for Energy Harvester Using a Piezoelectric Materials (압전소자를 이용한 에너지 하베스터용 전력변환장치 연구)

  • An, Hyunsung;Kim, Young-Cheol;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1059-1065
    • /
    • 2017
  • In this paper, the energy harvester with a piezoelectric materials is modeled as the electric equivalent circuit, and performances of a standard DC method and a Parallel-SSHI method are verified through experiment under variable force and load conditions. Piezoelectric generator consists of mass, damper and spring constant, and it is modeled by electrical equivalent circuit with RLC components. Standard DC and Parallel-SSHI are used as power conversion methods, and standard DC consists of full-bridge rectifier and smoothing capacitor. Parallel-SSHI method is composed of L-C resonant circuit, zero-crossing detector and full-bridge rectifier. In case of simulation under $100k{\Omega}$ load condition, the harvested power is $500{\mu}W$ in Standard DC and $670{\mu}W$ in Parallel-SSHI, respectively. In experiment, the harvested power under $100k{\Omega}$ load condition is $420{\mu}W$ in standard DC and $602{\mu}W$ in Parallel-SSHI. Harvested power of Parallel-SSHI is improved by approximately 40% more than that of standard DC method.

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.