• Title/Summary/Keyword: stability period

Search Result 1,554, Processing Time 0.024 seconds

Study on Dynamic Stability of Cylindrical Structure in Waves (파랑 중 실린더형 구조물의 동적 안정성에 대한 연구)

  • Jang, Min-Suk;Jo, Hyo-Jae;Hwang, Jae-Hyuk;Kim, Jae-Heui;Lee, Byeong-Seong;Park, Chung-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.196-201
    • /
    • 2017
  • A cylindrical structure has a very long period of heave and pitch motion response in ocean waves. To obtain the dynamic stability of a cylindrical structure, it is necessary to obtain the suitable metacentric height (GM). However, in a structure with sufficient metacentric height, Mathieu instability can occur if the natural frequency of the heave motion is double the natural frequency of the roll and pitch motion. This study carried out numerical calculations and experiments for vertical-axis wind turbines with cylindrical floaters, which had three different centers of gravity. In the regular wave experiment, the divergence of the structure motion without yaw was observed when the natural frequency of the heave motion was double the natural frequency of the roll and pitch motion. In the irregular wave experiment, the motion spectra of the structures with the different centers of gravity were compared, and one was very high when the natural frequency of the heave motion was double the natural frequency of the roll and pitch motion.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Instrument Flight Certification Process and Flight Test Results of Korean Utility Helicopter (한국형 기동헬기 계기비행 인증절차 및 비행시험 결과)

  • Kwon, Hyuk-Jun;Park, Jong-Hoo;Park, Jae-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.173-180
    • /
    • 2014
  • In this paper, the instrument flight certification process and flight test results of Korean Utility Helicopter (KUH) are presented. For the instrument flight certification, the suitability of installed equipments and instruments have been reviewed and verified by ground and flight tests. Next, static and dynamic stability test are conducted in accordance with FAR-29 Appendix B. The static stability is determined by the change of speed and attitude according to control inputs. The dynamic stability is evaluated by how quickly the response of the helicopter due to long and short period control inputs are decreased. The pilot workload evaluation are also carried out by simulated IMC flight tests. This paper presents the workload assessment results when some failures are occurred at cockpit instruments, engine or flight control systems as well as the normal situation. After the simulated IMC flight test is completed, actual instrument flight test are conducted in a real IMC environment according to the air traffic controls.

Effect of Mugwort Pelleted Diet on Storage Stability of Pork Loins (쑥 펠렛사료 급여가 돈육의 저장성에 미치는 영향)

  • 김병기;우선창;김영직
    • Food Science of Animal Resources
    • /
    • v.24 no.2
    • /
    • pp.121-127
    • /
    • 2004
  • This study was conducted to investigate the effect of dietary mugwort pelleted on the storage stability of pork. barrow (T1) and boar (T2) were alloted into six treatments: 1) control (commercial feed) 2) T1-1 and T2-1(commercial feed supplemented with 3.0% mugwort pelleted) 3) T1-2 and T2-2 (commercial feed supplemented with 5.0% mugwort pelleted). They were fed with the experimental diets for 60 days and slaughtered. Meat samples were in wrap package and stored at 4${\pm}$1$^{\circ}C$ for 10 days. pH, WHC and cooking loss were not siginificanly different in all treatment. But these values were tended to increase during storage for all treatment groups (p<0.05). Thiobarbituric acid reactive substances (TBARS) and Volatile Basic Nitrogen (VBN) values were low for pork samples prepared from pigs supplemented mugwort pelleted diet and the values were increased as storage period increased for all treatment groups (p<0.05). But L value was highest for pork samples prepared from pigs supplemented of 3.0% mugwort pelleted diet among treatments group.

Characteristics of Non-plasticizer PVAc Resin for Wood Products

  • Kim, Sumin;Kim, Hyun-Joong;Choi, Youn Mee;Jang, Sung-Wook
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.61-68
    • /
    • 2007
  • The applicable scope of adhesives in the current society is broad and currently, several types of PVAc resin are sold in the market for adhesives. PVAc resin is primarily used for wood works and paper adhesion. However, the PVAc resin itself has the disadvantages that its viscosity is highly temperature- dependent and the work condition and viscosity get worse at the low temperature in the winter seasons. Although phthalate-based plasticizer is used to complement these disadvantages, adhesion strength and heat-resistance are weakened by adding the phthalate-based plasticizer and in the winter period, the amount of quantity should be increased. Also in a high-density product, it worsens the work condition by causing a rise of viscosity and delays curing and in a low-density product, it worsens the storage stability by causing separate precipitation. In addition to these, the phthalate-based plasticizer as a material of causing environmental hormones is currently restricted in the advanced countries for its amount of use and also in the domestic market, it is necessary to prepare for the situation. This study has not only eliminated the disadvantages of PVAc resin emulsion without adding a phthalate-based plasticizer of causing these problems, but also synthesized the PVAc resin for timber adhesion that is excellent in woodwork, thermal-resistance, water-resistance, storage stability, and adhesion performance. As the result, it has proven an excellent performance in thermal resistance, water resistance, storage stability, and minimum film forming temperature.

Immobilization of Laccase on $SiO_2$ Nanocarriers Improves Its Stability and Reusability

  • Patel, Sanjay K.S.;Kalia, Vipin C.;Choi, Joon-Ho;Haw, Jung-Rim;Kim, In-Won;Lee, Jung Kul
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.5
    • /
    • pp.639-647
    • /
    • 2014
  • Laccases have a broad range of industrial applications. In this study, we immobilized laccase on $SiO_2$ nanoparticles to overcome problems associated with stability and reusability of the free enzyme. Among different reagents used to functionally activate the nanoparticles, glutaraldehyde was found to be the most effective for immobilization. Optimization of the immobilization pH, temperature, enzyme loading, and incubation period led to a maximum immobilization yield of 75.8% and an immobilization efficiency of 92.9%. The optimum pH and temperature for immobilized laccase were 3.5 and $45^{\circ}C$, respectively, which differed from the values of pH 3.0 and $40^{\circ}C$ obtained for the free enzyme. Immobilized laccase retained high residual activities over a broad range of pH and temperature. The kinetic parameter $V_{max}$ was slightly reduced from 1,890 to 1,630 ${\mu}mol/min/mg$ protein, and $K_m$ was increased from 29.3 to 45.6. The thermal stability of immobilized laccase was significantly higher than that of the free enzyme, with a half-life 11- and 18-fold higher at temperatures of $50^{\circ}C$ and $60^{\circ}C$, respectively. In addition, residual activity was 82.6% after 10 cycles of use. Thus, laccase immobilized on $SiO_2$ nanoparticles functionally activated with glutaraldehyde has broad pH and temperature ranges, thermostability, and high reusability compared with the free enzyme. It constitutes a notably efficient system for biotechnological applications.

Strain Analysis of Crust at the Stabilization Stage Using and Applied Statistical Analysis

  • Kim, Hyeong-Sin;Yun, Hyun-Seok;Chae, Byung-Gon;Choi, Jung-Hae;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.9-20
    • /
    • 2015
  • A strainmeter goes through a period of instability immediately after installation. To determine the stability of strainmeters installed around the Andong fault zone, South Korea, an x-MR control chart analysis and a T2 control chart analysis were conducted. The x-MR control chart analysis used an empirically determined 3σ control limit line to identify abnormal data in recently installed strain gauges. In the T2 control chart analysis, the control limit line was set at a confidence of 95%. A comparison of the early stage of measurement with the terminal stage of measurement for three months after installation indicates that stabilization depends on the location and direction of each strain gauge in x-MR control chart analysis. In the T2 control chart analysis, the number of values exceeding the control limit line decreased as the terminal stage was approached. Based on these results, it is suggested that the 3σ control limit line of an x-MR control chart can be used as a standard for single gauge stability, and that the 95% confidence limit of a T2 control chart analysis could be used as the standard for the stability of multi-gauge strainmeters.

The Effect of Various Humectants on Equilibrium Moisture Content and Storage Stability of Seasoned Squid (여러가지 보습제가 조미오징어 평형수분함량에 미치는 영향)

  • Rhee, Chul;Kang, Chang-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.704-710
    • /
    • 1988
  • This study was, firstly, to investigate water holding capacity in terms of variation of moisture sorption isotherms of seasoned squid treated with sodium lactate, glycerol, propylene glycol, sorbitol, mannitol, sodium benzoate, potassium sorbate and calcium propionate, and secondly, the effect of humectant treatments on storage stability was studied. The criteria for storage stability was based on three quality factors, namely, lipid oxiations, color development by non-enzymatic browning reactions and lipid oxidation, and mold growth. The effect of humectants on equilibrium moisture content was in the following increasing order; mannitol < sorbitol < sodium lactate < propylene glycol < glycerol. The experimental data indicated that sodium lactate has, in practice, potentially positive effect on processing of seasoned squid. During the storage period of 60 days, TBA values increased in all samples tested as humectants concentrations increased up to 10%. However, in the range of 1-7% sodium lactate treatment, the degree of lipid oxidation, browning reactions and mild growth were not high enough to affect the quality of seasoned squid, when compared with conventionally manufactured ones.

  • PDF

Influence analysis of continuous pile walls on the behavior of a soil tunnel at the shallow depth through a parametric study (민감도 분석을 통한 주열식벽체가 저토피 토사터널 거동에 미치는 영향 분석)

  • You, Kwang-Ho;Yoon, Woo-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.75-89
    • /
    • 2014
  • In recent years, utilization of underground space has been increasing in various parts of the world. In particular, open-cut method is usually applied to the shallow depth excavation. However some problems such as extreme traffic congestion and unstability of adjacent structures etc. might occur. In order to cope with these problems, the M-CAM (Modified Cellular Arch Method) method was proposed to excavate soil tunnels at shallow depth with secured enough stability and minimized construction period. In this study, sensitivity analysis was performed to predict the influence of the size of CPW(Continuous Pile Wall) and ground conditions on the behavior of the tunnel. First of all, embedded depth and diameter (or thickness) of CPW, coefficient of lateral earth pressure, and ground conditions were selected as parameters that could affect tunnel stability. Meanwhile, FLAC 2D based on finite difference method was used for numerical analysis. As a result of this study, it was checked out that embedded depth among sizes of CPW had a greatest influence on the stability of a tunnel.

Development of Quantification Method and Stability of ${\Delta}^9$-Tetrahydrocannabinol and 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol in Oral Fluid (타액 중 ${\Delta}^9$-Tetrahydrocannabinol 및 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol의 분석법 확립 및 안정성 검토)

  • Choi, Hye-Young;Baeck, Seung-Kyung;Jang, Moon-Hee;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.226-231
    • /
    • 2010
  • Oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing. In this study, an analytical method for the detection and quantification of ${\Delta}^9$-tetrahydrocannabinol (THC) and its metabolite, 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH) in oral fluid by SPE and GC-MS was established and fully validated. The stability of THC and THC-COOH in oral fluid during storage was also determined by examining the THC and THC-COOH concentration changes depending on time and container materials. Oral fluid samples were kept over 21 days at room temperature, $-4^{\circ}C$ and $-20^{\circ}C$ in two different specimen collection tubes; glass and polypropylene tubes. Three replicates for each condition with different temperature and types of a container were analyzed at five different time points over 21 days. When oral fluid samples were stored in glass tubes, the loss of both THC and THC-COOH was less than 10% at all room temperature, $-4^{\circ}C$ and $-20^{\circ}C$. However, in polypropylene tubes, the loss of both THC and THC-COOH increased significantly over the study period. In particular, the concentration of THC decreased more rapidly than that of THC-COOH at room temperature and the maximal percentage of THC lost was 90.3% after 21 days. The result indicates that it would be necessary to collect oral fluid samples in glass containers and cool the samples until analysis in order to prevent the degradation of analytes.