• Title/Summary/Keyword: square tube

Search Result 325, Processing Time 0.025 seconds

Precision and accuracy of CARS spectrometer for instantaneous temperature measurement (순간 온도 측정을 위한 CARS 분광기의 정밀 정확도 분석)

  • 박승남;박철융;한재원;길용석;정석호
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.348-356
    • /
    • 1996
  • A mobile CARS spectrometer is constructed to measure the instantaneous temperature of gases, of which software include the quick fit methods and a least square fitting method to obtain temperatures from the spectra. Two quick-fit-methods give smaller variance of temperatures than the least square fitting method even though they consume much shorter time to yield temperatures. The precision and accuracy of CARS temperature is measured in the graphite tube blackbody furnace in reference to a radiation pyrometer. The accuracy of the CARS temperature is $\pm$2% from 1000K to 2400K and the precision is $\pm$35K at 1600K with the most accurate quick-fit-method. As a demonstration of the instantaneous measurement, the spectrometer is applied for measurement of the turbulent combustion at a certain condition. eograms(HS) are made using a relatively small number of synthesized 2D images. The influence of aliasing artifacts caused by insufficient or improper sampling is presented, and a new sampling theory is proposed, which is used to making holographic stereograms. Also, the optical system for extension of viewing distance and viewing zone is proposed. Results of this analysis can be applied to design normal holographic stereograms and computer based holographic stereograms.

  • PDF

A Comparative Analysis of 119 Emergency Medical Service Operation of Korea and Japan (한국과 일본의 구급실태 비교연구)

  • Baek, Hong-Sok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.199-210
    • /
    • 2004
  • Since the 119 fire department was legally permitted to serve in Emergency Medical Service(EMS)Operation of emergency patients in 1983, 119 EMS operation in general has made a big progress in serving the needs for emergency patients. Currently EMS operation is carried out by 119 EMS unit, private ambulance Co.,etc. But due to the public recognition and volunteers, 119 EMS operation carries the major share of the service. This observation is not surprising in that such a trends occured in Japan 20 years ago. This paper compared the 119 EMS operation conducted by the fire department in Korea with that of Japan in order to draw some inferences from the comparison. The results of the study compared to Japan were as follows: 1. Japan was higher 1.5 times in the number of EMS units per population(100,000), 1.1 times in the number of patient transports per unit. 2. Japan was higher 4.54 times in the number of the 119 EMS personnel per population(100,000), 30.6 times in that per square killometers, 30.6 times per 119 EMS unit, in per ambulance 2.48times. 3. Japan was higher 1.83 times in the number of ambulance per population(100,000), 1.26 times in that per square killo meters. 4. Japan was higher 1.7 times in the number of transport patients per population (100,000), but Korea was higher 2.68 times in the transport patients per EMS personal. 5. Compared to Japan, there was no emergency care related to ALS, for example, such as administering dugs orally and intravenously, interpreting elctrocardiograms, performing endotracheal tube or LMA insertion, using monitors and other complex equipments in Korea.

  • PDF

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

Experimental Study of the Effect of Vibration on the Geomunoreum Lava Tube System in Jeju (제주 거문오름 용암동굴계의 진동영향에 관한 실험적 연구)

  • Song, Jae-Yong;Lee, Geun-Chun;Ahn, Ung-San;Lim, Hyun-Muk;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.327-345
    • /
    • 2020
  • The effects of ground vibration on lava tubes during construction were studied to aid design of management and preservation measures for lava tubes. Ground conditions were assessed by RMR (Rock mass rating) and Q-system classifications for the Geomunoreum lava tubes, and vibration velocity was measured during in situ blasting tests in the Manjanggul and Yongcheondonggul lava tubes. Results indicate that the higher the rock quality, the greater the effect of vibration, although there is no clear linear relationship due to ground heterogeneity. A relationship derived between vibration velocity (PPV) and intensity (dB(V)) on the basis of blasting tests indicates that a vibration level of < 0.285 cm/sec meets the regulatory limit of 0.371 cm/sec and 65 dB(V) during daytime, and 0.285 cm/sec and 60 dB(V) during night. For blasting vibrations, square- and cube-root scaled distances are linearly correlated, with R2 ≥ 0.76. On the basis of this correlation, explosive-charge weights meeting the 0.2 cm/sec vibration criterion for cultural heritage were estimated to be 2.88 kg at 50 m distance, and 11.52 kg at 100 m.

A Study on the Flow Entrainment Characteristics of a Coaxial Nozzle Used in a MILD Combustor with the Change of Nozzle Position and Flow Condition (MILD 연소로에서 노즐의 위치와 유동 조건에 따른 유입량 특성에 관한 연구)

  • Shim, Sung-Hoon;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • A MILD (Moderate and Intense Low oxygen Dilution) combustor decreases NOx formation effectively during the combustion process and NOx formation is affected significantly by the exhaust gas entrainment rate toward fuel and air. The present study focused on the new MILD combustor, which has coaxial cylindrical tube. The outside tube of the new MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. The connection pipe is set between the outer side and the inner side tubes and coaxial air nozzle is inserted at the center of the connection pipe. A numerical analysis is accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of air nozzle exit velocity, nozzle diameter, nozzle exit position and exhaust gas side pressure. The entrainment rate is proportional to the square root of air nozzle exit velocity and negatively proportional to the pressure difference between the exhaust gas side and furnace side pressures. The effect of air nozzle exit position is not considerable on the exhaust gas entrainment.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Experimental Study on Seismic Retrofit of Steel Moment Connections Considering Constraint Effect of the Floor Slab (바닥슬래브에 의해 구속된 철골 모멘트접합부의 내진보강에 관한 실험적 연구)

  • Oh, Sang Hoon;Kim, Young Ju;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.247-255
    • /
    • 2004
  • An experimental program was undertaken to develop seismic retrofit methods of existing steel moment connections with floor slab for improved seismic performance. Five full-scale composite specimens were tested under cyclic loading. Conventional through-diaphragm connections [please check this; no search results were found for through-diaphragm connections] composed of square-tube column and H-beam were retrofitted by adding either a bottom-flange dogbone (RBS) or an improved welded horizontal stiffener at the beam bottom flange. The effectiveness of the proposed retrofit connections schemes was evaluated. The specimen retrofitted using the RBS concept at the bottom flange showed poor connection ductility. In contrast. specimens with the proposed horizontal stiffener details exhibited improved connection ductility.

Experimental study on axial compressive behavior of welded built-up CFT stub columns made by cold-formed sections with different welding lines

  • Naghipour, Morteza;Yousofizinsaz, Ghazaleh;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • v.34 no.3
    • /
    • pp.347-359
    • /
    • 2020
  • The objective of this study is to experimentally scrutinize the axial performance of built-up concrete filled steel tube (CFT) columns composed of steel plates. In this case, the main parameters cross section types, compressive strength of filled concrete, and the effect of welding lines. Welded built-up steel box columns are fabricated by connecting two pieces of cold-formed U-shaped or four pieces of L-shaped thin steel plates with continuous penetration groove welding line located at mid-depth of stub column section. Furthermore, traditional square steel box sections with no welding lines are investigated for the comparison of axial behavior between the generic and build-up cross sections. Accordingly, 20 stub columns with thickness and height of 2 and 300 mm have been manufactured. As a result, welding lines in built-up specimens act as stiffeners because have higher strength and thickness in comparison to the plates. Subsequently, by increasing the welding lines, the load bearing capacity of stub columns has been increased in comparison to the traditional series. Furthermore, for specimens with the same confinement steel tubes and concrete core, increment of B/t ratio has reduced the ductility and axial strength.

Ignition Characteristics of JP-7 as a Scramjet Fuel (스크램제트 연료로써 JP-7 의 점화 특성)

  • Choi Jeong-Yeol;Puri Puneesh;Ma Fuhua;Yang Vigor
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.377-380
    • /
    • 2005
  • A study of ignition characteristics of cracked JP-7 fuel with both oxygen and air has been conducted over a wide range of pressures (1-20 atm), temperatures (1200-2000 K), and equivalence ratios (0.5-1.5). Correlations of ignition delay, of the form, $\tau=Aexp(E/RT)[F]^{a}[O_2]^{b}$ are established using the Chemkin-II package and least square analysis. The effect of $C_3$ hydrocarbons in cracked JP-7 fuel is examined by comparing the ignition delays for two different cracked compositions. A comparison for ignition delay is also made with the experimental results obtained by injecting liquid JP-7 fuel in air using a shock tube apparatus.

  • PDF

Photoluminescence Characteristics of ZnO Nanowires Grown on a-, c- and m-plane Oriented 4H-SiC Substrates (4H-SiC 기판의 a-, c-, m-면방향에 따른 ZnO 나노선의 Photoluminescence 특성 분석)

  • Kim, Ik-Ju;Yer, In-Hyung;Moon, Byung-Moo;Kang, Min-Seok;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.5
    • /
    • pp.349-352
    • /
    • 2012
  • ZnO thin films were deposited on a-, c- and m- plane oriented 4H-SiC substrates by pulsed laser deposition. ZnO nanowires were formed on substrates by tube furnace. Shape and density of the ZnO nanowires were investigated by field emission scanning electron microscope. Average surface roughness and root mean square surface roughness were measure by atomic force microscope. Optical properties were investigated by Photoluminescence measurement. Density of ZnO nanowires grown on a-, c- and m-plane oriented 4H-SiC substrates were 17.89 ${\mu}m^{-2}$, 9.98 ${\mu}m^{-2}$ and 2.61 ${\mu}m^{-2}$, respectively.