• Title/Summary/Keyword: specific field

Search Result 3,177, Processing Time 0.033 seconds

Object-Oriented Field Information Management Program Developed for Precision Agriculture

  • Sung J. H.;Choi K. M.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.50-57
    • /
    • 2003
  • This study was conducted to develop software which provides automatic site-specific field data acquisition, data processing, data mapping and management for precision agriculture. The developed software supports acquisition and processing of both digital and analog data streams. The architecture was object-oriented and each component in the architecture was developed as a separate class. In precision agriculture research, the laborious task of manual ground-truth data collection will be avoided using the developed software. In addition, gathering high-density data eliminates the need for interpolation of values for un-sampled areas. This software shows good potential for expansion and compatibility for variable-rate-application (VRA). The FIM (Field Information Management) computer program provides the user with an easy-to-follow process for field information management for precision agriculture.

  • PDF

COMPARISON OF NUMERICAL METHODS FOR TERNARY FLUID FLOWS: IMMERSED BOUNDARY, LEVEL-SET, AND PHASE-FIELD METHODS

  • LEE, SEUNGGYU;JEONG, DARAE;CHOI, YONGHO;KIM, JUNSEOK
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.20 no.1
    • /
    • pp.83-106
    • /
    • 2016
  • This paper reviews and compares three different methods for modeling incompressible and immiscible ternary fluid flows: the immersed boundary, level set, and phase-field methods. The immersed boundary method represents the moving interface by tracking the Lagrangian particles. In the level set method, an interface is defined implicitly by using the signed distance function, and its evolution is governed by a transport equation. In the phase-field method, the advective Cahn-Hilliard equation is used as the evolution equation, and its order parameter also implicitly defines an interface. Each method has its merits and demerits. We perform the several simulations under different conditions to examine the merits and demerits of each method. Based on the results, we determine the most suitable method depending on the specific modeling needs of different situations.

A Basic Study for the Development of Electrio-Cell Fusion Device and Performance-Improvement (전기적 세포융합기의 제작 및 성능 개선을 위한 기초 연구)

  • 이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Electrofusion of cabbage protoplasts was performed with a developed equipment which consists of a parallel wire electrode, a AC field generator, and a pulse generator. Exposure of protoplasts to an alternating current field of 450 KHz causes attraction to each other which leads to chains of protoplasts extending from the electrode. Intra-specific protoplast fusion was effectively induced within the pearl chains by the additional application of a single high-intensity DC square wave pulse of 1 KV/cm for 1-3 msec. To improve the performance, micro fusion electrode fabricated from the semiconductor technology and microcontroller based field an, d pulse generator was proposed. The viability of protoplasts after an application of electric field at optimum condition was reduced by only 5 % compared with that of pre-application. A prototype of fusion electrode, which consists of insulator-structure, was successfully fabricated by using photosensitive polyimide.

  • PDF

Research-Oriented Field Trip Education Facilitated by Mobile Phone (휴대폰을 활용한 탐구지향적 동물원 현장학습의 제안)

  • Kim, You-Min;Kim, Kyung-Min;Lim, Chang-Young
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.91-96
    • /
    • 2008
  • Field trip education is frequently used in a primary education in Korea. However, it fails to provide specific research activities or feedback for students and lacks educational implication. We propose a mission-based field trip education using mobile phone. In this paper, we explain our design process, experiment at the zoo, and discuss the future work.

  • PDF

Review of Recent Advancement of Ultra High Field Magnetic Resonance Imaging: from Anatomy to Tractography

  • Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: Advances of magnetic resonance imaging (MRI), especially that of the Ultra-High Field (UHF) MRI will be reviewed. Materials and Methods: Diffusion MRI data was obtained from a healthy adult young male of age 30 using a 7.0T research MRI scanner (Magnetom, Siemens) with 40 mT/m maximum gradient field. The specific imaging parameters used for the data acquisition were a single shot DW echo planar imaging. Results: Three areas of the imaging experiments are focused on for the study, namely the anatomy, angiography, and tractography. Conclusion: It is envisioned that, in near future, there will be more 7.0T MRIs for brain research and explosive clinical application research will also be developed, for example in the area of connectomics in neuroscience and clinical neurology and neurosurgery.

A Study on the Rheology Characteristics of Magnetic Fluids in a Circular Pipe (원관내 자성유체의 Rheology 특성에 관한 연구)

  • Jeon, Eon-Chan;Park, Joung-Woo;Kim, Tae-Ho;Kim, Soo-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.38-44
    • /
    • 2008
  • In the present paper, we theoretically analyze the flow of magnetic fluids in a circular pipe with a vertical magnetic field and investigate the magnetic response by the external magnetic field. Theoretical study through the governing equation derived by Siliomis is carried out with numerical analysis by the Gauss Elimination Method. Using polar and magnetic effect parameters, theoretical equations and distributions for the velocity, apparent viscosity as the magnetic response are shown. Especially, in the region of strong magnetic field the specific property is appeared by finding a critical magnetic effect parameter for a polar effect parameter.

  • PDF

Analytic Design Procedure of Three-mirror Telescope Corrected for Spherical Aberration, Coma, Astigmatism, and Petzval Field Curvature

  • Lee, Jong-Ung;Yu, Seung-Moon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.184-192
    • /
    • 2009
  • There are total eight degrees of freedom in designing a three-mirror system. If we correct four kinds of third order aberrations and the system should have the specified effective focal length, the remaining three degrees of freedom can be used for selecting a suitable configuration for a specific application. We suggest an analytic design procedure for a three-mirror telescope system which has a suitably sized secondary mirror and proper separations between mirrors, and is corrected for four kinds of third order aberrations, spherical aberration, coma, astigmatism, and field curvature. Two design examples are shown. One has a compact configuration with off-axial field, the other has relatively long configuration with annular ring field.

Design and control of quiet zone (principle and example) (조용한 공간 만들기 (방법론과 예))

  • Kim, Yang-Han;Yun, Du-Byeong;Nam, Gyeong-Uk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.565-570
    • /
    • 2000
  • In order to make a quiet zone, one can consider methods to generate a secondary sound field that cancels a primary sound field. Active noise control (ANC) is one of the kinds. This paper mainly deals with the issues on determining the optimal positions of control sources and sensors for making a desired quiet zone. The issues address the reason why the positions are important, how the positions are optimized, and what the measure on the optimal positions is in an uncertain sound field. It is also shown that a power control is applicable to a specific uncertain sound field. In addition, this paper shows that a control material method, which passively changes a boundary condition, is essentially found to be on the same road of ANC.

  • PDF

DNA Separation Chips Using Asymmetrically-Switched Nonuniform Electric Fields (비대칭 교차전기장의 불균일 분포를 이용한 DNA 분리 소자)

  • Yi, So-Yeon;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.265-268
    • /
    • 2009
  • We present the experimental study to realize a DNA separation chip using asymmetrically-switched nonuniform electric fields. The DNA separation chip redistributes DNA molecules within a specific area based on the size- and field-dependent nonlinearity of DNA drift velocity. The present chip is composed of a width variable channel to distribute nonuniform electric field, a DNA loading slit and a pair of electrodes to apply electric field. We focus on the design of DNA separation chips with identifying the nonlinearity of DNA drift velocity using three different DNA molecules (11.1kbp, 15.6kbp, and 48.5kbp) in the chips. It is demonstrated that different size of DNA shows different net migration in different direction under the asymmetrically-switched nonuniform electric field.

Cellmembrane Electrolyte Flow Research Using Electromagnetic Characteristics of Needle and Magnet (침과 자석의 전자기적 특성을 이용한 세포막 전해질 흐름 연구)

  • Lee, Y.J.;Park, M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.3-6
    • /
    • 2002
  • In this paper, the electrolyte flow treatment is suggested using together with needle and magnet. On account of Lorentz force law, we can not only induce the circulation of body fluids at specific hurt but also apply on the treatment of cell membrane voltage control controlling the electrolyte flow. If electric field is added to human body fluid, electrolyte and then magnetic field is taken by magnet, we can induce local region flow through needle, global region flow with artificial electrical field and magnetic field. Electrolyte flow is excellent treatment in clinical treatment.

  • PDF