• 제목/요약/키워드: space radiation measurement

검색결과 109건 처리시간 0.029초

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권1호
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

방사선학과 학생들의 공간선량 측정 경험이 방사선 안전 인식에 미치는 영향 (Radiological Safety Perception Change after Spatial Dose Measurement of Radiology Department Students)

  • 문재미;박상태;유지현
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.174-180
    • /
    • 2015
  • 예비 방사선 작업 종사자인 방사선학과 대학생을 대상으로 방사선 기초 개념과 공간선량 인식, 방사선 안전 인식에 대해 알아보고자 하였다. X선 촬영 실습실에서 X선 조사 시 발생하는 공간선량을 학생들이 직접 측정함으로써 방사선 기초 개념과 공간선량 인식에 따른 실험 전 후의 방사선 안전 인식 변화를 파악하고자 하였다. 그 결과 실험 후에 학생들의 방사선 안전 인식이 보수적이고 엄격하게 변화하는 것을 알 수 있었다. 그럼에도 불구하고 방사선학과 대학생들의 경우 방사선 안전 인식 보다 직업의식이 앞서는 형태를 볼 수 있었는데 이는 의료적 이용에 따른 이득을 우선적으로 고려한 결과로 생각된다. 이에 따라 의료적 이익의 범위 내에서 방사선 이용에 따른 세분화된 안전교육 프로그램이 필요성이 요구된다. 따라서 시청각 자료를 이용한 단순한 강의 중심의 안전 교육이 아닌, 직접 공간선량 측정 실험과 같은 체험적 안전 교육 프로그램을 제안하는 바이며 방사선 안전 인식의 보수적인 관점과 엄격한 태도를 지향하는 직업의식 교육이 필요한 것으로 파악되었다.

임베디드 시스템에 의한 방사선의 무선계측 (The Wireless Radiation Measurement Using Embedded System)

  • 김형종;박대성;이상복
    • 한국방사선학회논문지
    • /
    • 제2권1호
    • /
    • pp.11-16
    • /
    • 2008
  • 방사선은 의학, 이공학, 농학, 기타 산업분야 등에서 사용영역이 매우 넓고 방사선이용기술의 개발로 방사선의 이용 빈도는 계속 증가되고 있다. 방사선의 인류에 대한 공헌은 지대하지만 생체에 미치는 영향으로 인하여 방사선에 의한 장해 또한 간과할 수 없는 부분이다. 방사선을 유효적절하게 이용하면서 장해를 방지하기 위해서는 방사선을 정확하게 계측하여야 하며 이에 따른 연구와 교육이 철저하게 이루어 져야만 한다. 본 연구에서는 유비쿼터스 컴퓨팅기술을 이용하여 생체에 유해한 작용을 하는 방사선을 방사선선원에 접근하지 않고 무선으로 시간과 장소에 제한 없이 방사선을 계측할 수 있는 방안을 제안하였다. 제안된 방안의 구현은 무선전송 기술은 CDMA망을 이용하였고, 임베디드시스템(embedded system)을 PDA에 내장한 후, 고정된 IP를 가지는 방사선계측시스템에 PDA를 CDMA망에 접속하여 계측값을 디스플레이 하였다. 본 연구에서 제안된 방안을 이용한다면 인간이 유해한 방사선선원에 접근하지 않고 선원에 배치된 고정된 IP를 가지고 있는 방사선계측시스템을 통하여 CDMA망으로 PDA에 표시된 계측값을 읽을 수 있게 될 것이다.

  • PDF

무인 원격 방사선 검출 모듈 개발 (Development of Unmanned Remote Radiation Detection Module)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.795-801
    • /
    • 2021
  • 원전 해체 작업장의 요구에 따라 드론 기반 무인 원격 방사선 검출 모듈을 개발하였다. 사람이 접근해서 방사선을 측정할 수 없는 원자력 발전소 격납용기 내부 상공 및 외부로 누설되는 방사선 측정을 위한 목적으로 저준위에 민감한 GM-tube를 사용하여 제작하였다. 드론 기반 방사선 검출 모듈의 무게는 200g 미만으로 원자력 발전소 격납용기 내부의 상공과 외부 공중에서도 운용이 가능하다. 설계된 장비의 성능 확인을 위해 국제 기준 (IEC60864)을 참고하여 성능평가 실험을 시행하였다. 현장의 요구에 맞게 설계된 방사선 검출 모듈의 안정성은 측정 정확도를 평가하기 위한 변동률 실험에서 반복 측정에 의한 통계적 변동률은 ±4.6%. 선량률 의존성을 평가하기 위한 선형성 실험에서 정확도 ± 7.3%, 전체 선형도는 ± 3.5%이며 성능평가를 위한 국제기준을 만족하였다. 본 연구에서 개발한 무인 원격 방사선 검출 모듈은 원전 해체 작업장 맞춤형 장비로, 방사선 분진이 많은 현장에서 정확한 공간선량률의 측정과 방사선 작업장 안전관리에 도움을 줄 수 있을 것으로 확신한다.

비행고도 상에서의 우주방사선 관측 및 모델 비교 (Radiation Dose Measurement and Model Comparison at the Flight Level)

  • 이원형;김지영;장근일
    • 한국항공운항학회지
    • /
    • 제26권2호
    • /
    • pp.91-97
    • /
    • 2018
  • High-energy charged particles are comprised of galactic cosmic rays and solar energetic particles which are mainly originated from the supernova explosion, active galactic nuclei, and the Sun. These primary charged particles which have sufficient energy to penetrate the Earth's magnetic field collide with the Earth's upper atmosphere, that is $N_2$ and $O_2$, and create secondary particles and ionizing radiation. The ionizing radiation can be measured at commercial flight altitude. So it is recommended to manage radiation dose of aircrew as workers under radiation environment to protect their health and safety. However, it is hard to deploy radiation measurement instrument to commercial aircrafts and monitor radiation dose continuously. So the numerical model calculation is performed to assess radiation exposure at flight altitude. In this paper, we present comparison result between measurement data recorded on several flights and estimation data calculated using model and examine the characteristics of the radiation environment in the atmosphere.

이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구 (Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen)

  • 박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

CURRENT TRENDS IN IONIZING RADIATION DETECTION

  • Wehe David K.
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.311-318
    • /
    • 2006
  • Ionizing radiation is a both a natural and man-made phenomena that plays a major role in contemporary applications. The detection of this radiation has evolved over the past several decades from simple observations to precise measurements in space, time, and energy, even in harsh environmental conditions. Tn this paper, we present a snapshot of the current state-of-the-art in radiation measurement technology, highlighting the major applications and detector developments.

차량 내부에서의 모노폴 안테나 방사패턴 연구 (A Study on Monopole Antenna Radiation Pattern inside Vehicle)

  • 이태학;표성민;박상명;김영식
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4537-4542
    • /
    • 2010
  • 본 논문에서는 차량 내부에서 발생되는 안테나 방사패턴의 변화를 관찰하기 위해 모노폴 안테나를 사용하여 차량 내부에서 안테나의 방사패턴을 측정하였다. 다수의 반사파가 존재하는 좁은 공간에서는 안테나의 특성이 변해 무선 통신 환경에 영향을 끼칠 수 있다. 그러므로 실제 차량 내부에서 제공되는 무선 통신 서비스인 GPS 와 Wibro 동작 주파수 대역에서 안테나 방사패턴에 대한 모의실험과 측정실험을 수행하였다. 모의실험은 광선추적법을 기반으로 하였으며 측정실험은 각 동작 주파수 대역을 중심 주파수로 갖는 두 쌍의 모노폴 안테나를 제작하여 자유공간과 차량 내부에서 주파수에 따라 방사패턴을 측정하였다. 모의실험과 측정실험의 결과를 바탕으로 차량 내부와 자유공간에서의 안테나 방사패턴을 비교하였을 때 안테나의 전방향성 특성을 유지되며, 차량 내부에서 안테나의 수신전력이 자유공간에서의 결과보다 증가하는 것을 확인 할 수 있었다. 또한 주파수가 증가할수록 자유공간과 차량 내부에서의 수신전력 차이가 증가하는 것을 확인하였다.

국립공원의 해발고도에 따른 환경방사선 측정 (Measurement of Environmental Radiation according to Altitude above Sea Level in National Park)

  • 지태정;이인식
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.694-701
    • /
    • 2012
  • 본 연구는 국가환경방사선 자동감시망이 설치되지 않은 국립공원의 산악 지역을 대상으로 환경방사선을 측정하였다. 측정 방법은 지표 1m 높이에서 공간선량과 지표면에서의 지표선량을 측정하였다. 국립공원 선정은 중부지역과 남부지역을 같은 분포로 하여 전국에 10곳을 선정하였다. 측정장비는 감마선측정에 활용되는 INTERCEPTOR$^{TM}$(Thermo, USA, 2006)를 사용하였다. 방사선측정은 국립공원 입구와 정상에서는 필수적으로 측정하였고, 그 외 지점은 해발 고도를 500m 단위로 구분하여 탐방객이 많이 다니는 곳에서 측정하였다. 측정횟수는 각 지점에서 2분간 장비를 안정시킨 후 5회 이상 측정하였다. 측정결과, 공간감마선량의 경우 1,000m 이하 국립공원에서는 해발 고도 500m 지점에서 높은 선량이 측정되었다. 그 중 북한산, 계룡산, 월출산에서 $0.23{\mu}Svh^{-1}$ 이상인 것으로 확인되었다. 1,000m 이상의 국립공원에서는 설악산 1,500m 지점에서 $1.77{\mu}Svh^{-1}$로 측정되어 백그라운드 기준 선량보다 10배 이상 증가하였다. 선량에 유의한 변화를 보이지 않은 국립공원은 내장산, 소백산, 지리산으로 확인되었다. 환경방사선량이 낮게 측정된 산은 가야산 정상(1,430m)에서 $0.04{\mu}Svh^{-1}$, 한라산 정상(1,950m)에서 $0.03{\mu}Svh^{-1}$인 것으로 확인되었다. 지표선량 측정에서도 중간 높이인 500m, 1,000m에서 높게 측정되었다. 지각 구성물질의 종류에 따른 측정에서는 암석으로 구성된 국립공원에서 높은 선량으로 조사되었으며, 화산활동이 일어났던 한라산에서는 환경방사선량이 낮게 측정되었다.