• Title/Summary/Keyword: source analysis

Search Result 9,111, Processing Time 0.03 seconds

Numerical Analysis of Welding Residual Stress Using Heat Source Models for the Multi-Pass Weldment

  • Bae, Dong-Ho;Kim, Chul-Han;Cho, Seon-Young;Hong, Jung-Kyun;Tsai, Chon-Liang
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1054-1064
    • /
    • 2002
  • Numerical prediction of welding-induced residual stresses using the finite element method has been a common practice in the development or refinement of welded product designs. Various researchers have studied several thermal models associated with the welding process. Among these thermal models, ramp heat input and double-ellipsoid moving source have been investigated. These heat-source models predict the temperature fields and history with or without accuracy. However, these models can predict the thermal characteristics of the welding process that influence the formation of the inherent plastic strains, which ultimately determines the final state of residual stresses in the weldment. The magnitude and distribution of residual stresses are compared. Although the two models predict similar magnitude of the longitudinal stress, the double-ellipsoid moving source model predicts wider tensile stress zones than the other one. And, both the ramp heating and moving source models predict the stress results in reasonable agreement with the experimental data.

In-situ Performance Evaluation of a Ground Source Heat Pump for an Air Conditioning System (공조시스템용 지열히트펌프의 실증평가에 관한 연구)

  • Park, Youn-Cheol;Park, Seong-Koo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • In this study, the ground source heat pump was installed at a research center in Jeju Island to verify the performance of the system and to give an information for a economic feasibility. The performance test was conducted until the heat storage tank temperature reached at $5^{\circ}C$ from $50^{\circ}C$ in the cooling operation, and until the storage temperature goes up to $50^{\circ}C$ from $10^{\circ}C$ in the heating mode. As results, the system performance shows that $2.2{\sim}3.5$ for the cooling operation and $2.5{\sim}3.5$ for heating operation. It is found that the underground is good heat source for the heat pump with $3{\sim}10^{\circ}C$ variation range. The ground source heat pump could be connected one of air conditioning system without any problem in system performance. Based on the economic analysis, the initial cost for the ground source heat pump will be compensated after 4 years operation. If the system runs 20 years, approximately 300 million Won will be saved when the air conditioning system adapt the ground source heat pump based on Life Cycle Cost analysis.

The Information Search Behavior for Service Quality of Travel Agents (소비자 정보탐색활동이 여행 서비스품질 인식에 미치는 영향에 관한 연구)

  • Chun, Chang-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1113-1120
    • /
    • 2016
  • The purpose of this study is to find the important travel agency service quality factors in relation to the amount of information search efforts through major information channels of customers such as interpersonal source, retailer source, and external media source. Factor analysis using varimax rotation was performed and 20 service attributes of travel agent was reduced to 6 factors; convenience system, personal service, customer maintaining service, reputation, atmosphere and accessibility. According to MANOVA analysis there are significant differences in the service quality factor due to the type of source and amount of efforts of information search.

Analysis of Connected Operations of PV Source and Li Energy Storage Equipment to Power System (태양광 전원과 리튬 에너지 저장장치의 연계운전시 특성 해석)

  • Kim, Deok Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.106-112
    • /
    • 2014
  • This paper presents the analysis of connected operation of photo voltaic source and Li energy storage system. The micro-grid has been installed and operated for several years at the campus of USF and has been a role of test bed. Photo voltaic source has been strongly influenced by the location, weather and climate of a installed area and Li battery is connected directly to the photo voltaic source to compensate for the limitations. The Li battery is operated to supply power output to the grid by the charging or discharging mode based on the average power output of the PV source which is calculated from monitored data for several years. The load of the PV and Li battery system is operated as a severe loading condition and the operating characteristics of PV source and Li battery are analyzed in detail. In connected operations of PV and Li battery to power system, the PV and Li battery is operated to supply constant power during only day time or peak time to increase load shedding ratio and efficient usage of generation sources in power system.

Internal Resistive Source Modeling Technique for the Efficient Analysis of Planar Microwave Circuits Using FDTD (FDTD를 이용한 평판 구조 마이크로파 회로의 효율적인 해석을 위한 내부 저항 소스 모델링 방법)

  • 지정근;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.227-236
    • /
    • 1999
  • The finite difference time domain method (FDTD) is widely applied to the analysis of various microwave circuits. However, previous source modeling techniques have a lot of constraints and difficulties to apply for general geometries. Therefore, the internal resistive source modeling technique is suggested for efficiently analyzing various types of microwave circuit in this paper. Its efficiency is proved by comparing the computation time with that of hard source modeling. Accuracy is also verified by comparing the scattering parameters with those of previous source modeling methods and measurements for several microwave circuits.

  • PDF

A Study on the Simplified Economics Evaluation Method for Selecting a Heat Source System at the Pre-design Phase (초기계획단계에서 열원시스템 선정을 위한 경제성 간이 평가법에 관한 연구)

  • Park Yool;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1060-1067
    • /
    • 2004
  • To apply an analysis method of life cycle cost when assessing economics of equipment system, we should basically set up preconditions such as useful life, price escalation rate, interest rate, etc. as well as consider a calculation algorism of source energy and heat source system, which is a complex process for life cycle costing. For this reason, equipment designers tend to plan heat source systems, without a thorough investigation on economics of alternative systems at the pre-design phase. In this process, architectural designers should adopt a proper heat source system, which is one of the most important factors for planning an appropriate architectural design, through a discussion with equipment designers in a short time. In order to offer an evaluation method for equipment designers to analyze economics of an alternative heat source system easily at the pre-design phase, this research would define the simplified economics, evaluation method through analysis of existing papers for economics evaluation, and examine validity through comparison of simplified method values ($LCC_{EC}$) and life cycle costing values ($LCC_{15}$) for six alternative heat source systems.

Wind tunnel study of plume dispersion with varying source emission configurations

  • Wittwer, Adrian R.;Loredo-Souza, Acir M.;Schettini, Edith B. Camano;Castro, Hugo G.
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.417-430
    • /
    • 2018
  • The concentration fields in the proximities of a local gas emission source are experimentally analyzed in several combinations of wind incidences and source emissions. These conditions are determined by the plume buoyancy, emission velocity and incident flow wind speed. Concentration measurements are performed by an aspirating probe in a boundary layer wind tunnel. The analysis included the mean concentration values and the intensity of concentration fluctuations in a neutral atmospheric boundary layer flow. Different configurations are tested: an isolated stack in a homogeneous terrain and a stack with a bluff body in close proximity, located windward and leeward from the emission source. The experimental mean concentration values are contrasted with Gaussian profiles and the dilution factor is analyzed with respect to the empirical curves of the minimum dilution. Finally, a study on the plume intermittency is performed in a cross-sectional plane near the emission source. It is possible to highlight the following observations: a) plume vertical asymmetry in the case of an isolated emission source, b) significant differences in the dispersion process related to the relative location of the emission source and bluff body effects, and c) different probabilistic behavior of the concentration fluctuation data in a cross-sectional measurement plane inside the plume.

Determinants of Entirely Retired Men's Main Income Source and the Amount of Income (완전은퇴 남성의 주된 소득원천 및 소득액 결정요인)

  • Kim, Ji-Kyung;Kim, Ha-Nui
    • Journal of Family Resource Management and Policy Review
    • /
    • v.12 no.1
    • /
    • pp.57-89
    • /
    • 2008
  • Using the data of 'middle-and old-aged people' in the 6th year(2003) of KLIPS(Korea Labor and Income Panel Study), this study compared entirely retired men's income source and amount of income divided by the time of retirement and analyzed the determinants of main income source and amount of income level using Multinomial Logit Analysis and Tobit Analysis. The results of these were as following; First, Entirely retired men has average 1.27 income source and the amount of income from main income source is positioned at 85% of total income. This result indicates the lack of variety to get opportunities of income sources for the living and also means high risk associated with the entirely retired men if he looses the main income source. Second, most of income source of entirely retired men is spouse's earned income or private income transfers, however, if we divide those as timing of retirement and characters of each individual, it is represented that the most of income source is differentiated by the position at labor market during work life and the opportunity for building the wealth, and the possibility of obtaining public pension and public support. Third, the income level depends on what sort of income source the retired men has, this shows that there is not a strong relationship between obtaining a Income source and gaining above the certain level of income.

  • PDF

Analysis of inconsistent source sampling in monte carlo weight-window variance reduction methods

  • Griesheimer, David P.;Sandhu, Virinder S.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1172-1180
    • /
    • 2017
  • The application of Monte Carlo (MC) to large-scale fixed-source problems has recently become possible with new hybrid methods that automate generation of parameters for variance reduction techniques. Two common variance reduction techniques, weight windows and source biasing, have been automated and popularized by the consistent adjoint-driven importance sampling (CADIS) method. This method uses the adjoint solution from an inexpensive deterministic calculation to define a consistent set of weight windows and source particles for a subsequent MC calculation. One of the motivations for source consistency is to avoid the splitting or rouletting of particles at birth, which requires computational resources. However, it is not always possible or desirable to implement such consistency, which results in inconsistent source biasing. This paper develops an original framework that mathematically expresses the coupling of the weight window and source biasing techniques, allowing the authors to explore the impact of inconsistent source sampling on the variance of MC results. A numerical experiment supports this new framework and suggests that certain classes of problems may be relatively insensitive to inconsistent source sampling schemes with moderate levels of splitting and rouletting.

Design and Analysis of High Stability Stabilized Power Source (고안정도 안정화전원의 설계와 해석)

  • Kim, Joo-Hong;Bo, Sim-Kwang
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.5
    • /
    • pp.22-28
    • /
    • 1977
  • This is a design and analysis of the D.C. highly stabilized power source. This appratus has 10**-7 order of the voltage regulation and 40V, 1.5A, continuosly variable D.C. output. Authors inspected the effect of the OP Amp, FET and the load circuit to the stationary and transient characteristics of the apparatus. Authors found that it is a useful method for high performance of the stabilized power source to utilize IC OP Amp and FET as the elements of it.

  • PDF