• 제목/요약/키워드: sound vibration

검색결과 2,252건 처리시간 0.029초

에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측 (Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner)

  • 장서일;최진권;손진희;모진용;구형모
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

하부틈새 크기에 따른 도어의 음향감쇠계수 분석 (Sound Reduction Index of Interior Door by Aperture Sizes at Door's Bottom)

  • 김명준
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.834-840
    • /
    • 2010
  • The Sound reduction indices(SRIs) of interior door with 13 different size apertures are measured in acoustic chamber. Also, as a theoretical approach, the SRIs are estimated using Gomperts' theory. In this study, the aperture of interior door is focused on the lower part of door leaf which is well known as a main cause to deteriorate the sound insulation performance of door. The results show that the SRI of door strongly depends on the aperture width and the dip in the measured sound reduction index curve by the resonance effect within aperture is observed at high-frequency. On the whole, the values calculated by theory are in good agreement with the measured values including the position of resonance dip. The average difference between the measured and the calculated values is 0.9 dB for 13 doors with different size aperture in terms of the weighted SRI.

항공기소음에 노출된 학교 교실 창호 설계에 관한 연구 (A Study on the Window Design of School Class Room Exposed to The Aircraft Noise)

  • 송혁;송민정;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.710-717
    • /
    • 2003
  • This study aim to find an appropriate window for class rooms to provide proper sound insulation against aircraft noise and to achieve this, measurements were taken of the sound insulation performance of windows with varying thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of (his study the improvement of the sound insulation performance of windows(single , double and triple window) has been shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide data lot the improvement of the sound insulation performance of windows.

  • PDF

간이 차음시험장치 개발 (Development of a Simplified Test Apparatus for Measuring Sound Transmission Loss)

  • 이해성;전오성;강현주;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.892-897
    • /
    • 2003
  • This study deals with the performance of a simplified test apparatus for measurement of sound insulation of panels. In order to investigate its performance, results from experiment and theory of the sound transmission loss for single and double panels are compared. Comparative results show that in evaluation of the sound insulation performance, the test apparatus has a cumbersome problem at the low frequency region, i.e. below 315 ㎐, presumably because of the poor diffuse sound field in the chambers. Meanwhile at the high frequency, it shows a considerable results comparable to the theoretical prediction. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

차음성능 계측시 터널링 효과에 관한 해석적 연구 (Tunneling Effect on Sound Transmission Loss Measurement)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1228-1233
    • /
    • 2002
  • This study is aimed to evaluate a tunneling effect in association with the measurement of sound transmission loss. Based on the formulation for sound transmission loss of a finite panel in the presence of tunnel, variations of the sound transmission loss with parameters such as the location of panel and tunnel depth are investigated. It can be seen that differences in the sound transmission loss are quite evident below coincidence frequency and the sound transmission loss greatly depends on panel location in the tunnel. In comparison with the case without a tunnel, maximum difference occurs in the case where the panel is placed on the center of the tunnel and the flushing with the end of the tunnel gives the better estimation of transmission loss.

  • PDF

토출소음 저감을 위한 차량 흡기시스템 레이아웃 설계 (Layout design of the vehicle intake system for reducing the radiated noise)

  • 김회전;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.443-446
    • /
    • 2006
  • For the satisfaction of the high engine performance and the low radiated sound pressure simultaneously, the duct length in the vehicle intake/exhaust system should be tuned carefully in the design and development stage of a vehicle. This study was concerned about the effects of intake duct length in clean and dirty sides on the radiated sound emitted from an inlet. An index derived from the existing prediction model of radiated sound pressure was employed to determine which duct was more influential to the radiated sound. Comparing the experimental and predicted results, we found that the change of dirty-side duct length caused a larger change than that in the clean side in the radiated sound level from a tested intake system.

  • PDF

벽체 우회전달음 영향요소에 관한 연구 (A Study on the Factor of Flanking Noise in the Wall)

  • 정진연;정갑철
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.143-148
    • /
    • 2007
  • This study examines the influence factor of flanking noise in the wall. Generally, there is the difference of airborne sound isolation between laboratory and field test. The purpose of this study is examing the cause of droping sound insulation performance in the field and searching the method of improving sound insulation performance. First, we measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the flanking noise and solid transmission. For the flanking noise in the wall, we used intensive method. So, we found the influence of solid transmission.

슬래브 두께 및 강도의 변화에 따른 바닥 충격음 특성에 관한 연구 (A Study on the Reduction of Floor Impact Sound according to the Thickness and Stiffness of Slab)

  • 박인선;김태희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.276-277
    • /
    • 2012
  • This study was carried out in the laboratory of the reverberation. A total of six specimens were fabricated depending on the thickness and strength. Floor impact sound insulation performance was measured in 1/3 octave band center frequency. The results of this study are as follows. Although some differences in the frequency band, the result of evaluating the weight impact sound blocking performance as the thickness increases, the floor impact sound insulation performance is improved. In addition, to increase the strength of the slab, even if the block impact sound performance is improved.

  • PDF

흡음형 방음벽의 내부 구성에 따른 흡음특성 (Sound Absorbing Characteristics According to Interior Configuration of Noise Barrier)

  • 박진규;김상헌;김관주;박희준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.387-392
    • /
    • 2003
  • This study is put a focus on the identification of sound characteristics according to the interior configuration of sound absorption material and air gap. Noise barrier is general consists of front perforated panel, air layer, sound absorption material, air gap and back plate. Noise barrier is required to the NRC value of 0.7. The absorbing performance of the noise barrier relies on the opening ratio of the perforated panel and the efficiency of the absorbing material. This study has observed the effect of opening ratio and hole size, the increase of sound absorbing performance by the configurations of sound absorption material and air gap. New designed noise barrier is achieved the acoustical performance of 0.87 the measurement in a reveration room.

  • PDF

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Sound Barrier)

  • 허영;김홍식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF