• Title/Summary/Keyword: sound vibration

Search Result 2,252, Processing Time 0.027 seconds

Factors for Speech Signal Time Delay Estimation (음성 신호를 이용한 시간지연 추정에 미치는 영향들에 관한 연구)

  • Kwon, Byoung-Ho;Park, Young-Jin;Park, Youn-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.909-915
    • /
    • 2008
  • Researches for time delay estimation had been studied broadly. However studies about factors for time delay estimation are insufficient, especially in case of real environment application. In 1997, Brandstein and Siverman announced that performance of time delay estimation deteriorates as reverberant time of room increases. Even though reverberant time of room is same, performance of estimation is different as the specific part of signals. In order to know that reason, we studied and analyzed the factors for time delay estimation using speech signal and room impulse response. In result, we can know that performance of time delay estimation is changed by different R/D ratio and signal characteristics in spite of same reverberant time.

  • PDF

Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment (주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가)

  • Jeon, Jin-Yong;Kim, Kyong-Ho;Jung, Jeong-Ho;Ryu, Jong-Kwan;Cho, Moon-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

Noise Characteristics of Air Cleaners and Humidifiers (공기청정기와 가습기의 소음특성)

  • Kim, Yong Hee;Park, Ji Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study investigated noise characteristics of air cleaners and humidifiers in terms of frequency domains and measurement directions. Noise levels of 31 air cleaners and 36 humidifiers were measured in an anechoic chamber according to the related group standards. As for air cleaners, 5 receiving points of 1 m off from front, rear, left, right and top surfaces of the product were considered. In case of humidifiers, 4 receiving points without the rear position were considered in the same manner as air cleaners. In each case, A-weighted equivalent continuous sound level was measured three times for 1 min. As a results, most of the measured air cleaners and humidifiers showed the highest noise levels at top directions due to the air ventilating location. In case of air cleaners, averaged noise levels of top and rear positions were 49.9 and 48.2 dB(A), respectively, whereas averaged noise level of other positions was all 45.2 dB(A). In case of humidifiers, averaged noise level of top position was 44.1 dB(A) whereas averaged noise levels of other positions were 38.7 to 39.1 dB(A). In addition, high frequency content of 1 kHz and 3.15 kHz to 4 kHz for air cleaners and middle frequency content of 500 Hz to 1.6 kHz for humidifiers showed significant contribution to determination of overall noise levels with correlation coefficient of 0.9 and above.

Trend of sound quality development in vehicles (자동차 음질 개발 동향)

  • Kang, Koo-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.327-327
    • /
    • 2010
  • 자동차에서 실내음질은 구매결정 요소들 중의 하나로 그 중요성이 점차 증가하고 있다. 따라서 다양한 운전조건에서 운전자가 기대하는 실내음질의 기대 수준을 충족시켜야 한다. 소비자는 운전경험과 습관에 따라 기대하는 음질에 차이가 있고 소리에 대한 표현방식도 모호하기 때문에 이러한 주관적 특성을 하나의 통일된 표현으로 정의 하기가 어렵다. 그러나 지난 이십여 년 동안의 음질개발과 차량 실내소음 주관평가의 통계처리로 통일된 표현을 할 수 있었다. 나아가 심리음향학 및 신호처리기술의 발달과 꾸준한 음질연구결과로 소리특성을 객관적으로 나타내는 소리의 시각화가 가능하였으며, 운전자가 인식하는 주관평가와의 상관관계를 높여 차량의 대표적인 음질인자로 정량화하여 음질목표를 설정할 수 있었다. 실내소음의 구성은 엔진 투과음, 흡배기 소음, 바람 소음, 도로 기인 소음 등으로 다양하므로 소음원에 따라 음의 균형을 맞추어 조화로운 음질개발을 하는 것이 중요했다. 또한 차량 판매되는 지역에 따라 선호음이 상이하여 지역별 실내음질의 차별화가 필요했다. 궁극적으로는 운전자의 감성품질을 만족할 수 있도록 음을 제어하여 브랜드 사운드를 개발하고 있다. 이러한 실내음질을 달성하기 위한 방법으로 소음원과 전달경로에 대해 기여도를 분석하고, 경로를 구성하는 시스템 별로 세분화하여 시스템 목표를 설정하였다. 시스템 개발에 중요한 인자로 차량의 동강성 및 흡차음 성능을 들 수 있다. 특히 디젤차량의 비중이 큰 유럽업체의 차량의 동강성 및 흡차음 개발 능력은 높게 평가되고 있다. 이에 유럽의 부품전문회사가 가지고 있는 해석과 시험적인 개발 방법을 통하여 전달계 특성을 만족하기 위한 시스템의 동강성 및 흡차음 특성을 개발하고 있다. 차량음질 튜닝의 중요한 기법 중 하나로 흡배기 개발을 추진하고 있다. 친환경자동차인 하이브리드차량, 전기차량 및 연료전지차량의 경우 전기구동부품에서 발생하는 각종 이음 발생을 최소화 했다. 보행자를 보호하고 운전의 즐거움을 향상하기 위한 가상사운드 개발을 진행하고 있다. 회사 수익성 향상을 위한 원가절감 및 구조 경량화에 따른 음질악화와 연비 향상 및 배기가스 규제 강화로 고성능 고출력 엔진탑재에 따른 음질악화 요인을 극복해야 했다. 운전자의 청감은 차량의 운전성에 따라서도 크게 영향을 받게 되므로 엔진제어와 변속기제어를 통해 음질과 운전성이 조화를 이룰 수 있도록 개발하고 있다. 향후, 소음원에 따른 시스템 최적화 개발, 운전성과 음질 연계 개발과 친환경차량의 가상사운드 개발 등이 자동차 음질 개발의 중요한 이슈로 생각한다.

  • PDF

A study on the estimation of acoustic performance of exhaust system with 3 dimensional visco-convective wave equation and dopplerized algorithm (3차원 대류 파동 방정식과 도플러 알고리즘을 이용한 배기계의 소음 성능 예측에 관한 연구)

  • Jang, Jin-Man;Kim, June-Wan;Kim, Joong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.821-832
    • /
    • 2011
  • Recently, the noise of vehicle is the one of the key factors for customers to purchase a vehicle and the most important part which is related to the noise is the exhaust system. Thus, car makers have their own ways to assess this exhaust noise not only to decrease the level of noise but to enhance the feeling of it. Typically, to do these things in the early stage of development, the tuning code of the exhaust system has to be made by CAE tool, which is very reliable but expensive, and the prototype parts of this code would be made for the validation test. Then this process can be iterated to meet the target of the performance. In this study, a new algorithm which adapts the '3 dimensional convective sound wave theory 'and 'Doppler effect' has been developed. With this new algorithm, a brand new system for the calculation of tail pipe noise has been developed and validated by acoustic wind tunnel test. As a result of this study, various comparisons and have been carried out, for example, the comparison with other CAE tool has been performed for the validity and the improvement of the new calculation code could be achieved.

  • PDF

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Study on Topology Optimization for Eigenfrequency of Plates with Composite Materials (복합재료판 구조물의 고유진동수 위상최적화에 관한 연구)

  • Kim, Hwa-Ill;Yun, Hyug-Gee;Han, Kyong-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1356-1363
    • /
    • 2009
  • The aim of this research is to construct eigenfrequency optimization codes for plates with Arbitrary Rank Microstructures. From among noise factors, resonance sound is main reason for floor's solid noise. But, Resonance-elusion design codes are not fixed so far. Besides, The prediction of composite material's capability and an resonance elusion by controlling natural frequency of plate depend on designer's experiences. In this paper, First, using computer program with arbitrary rank microstructure, variation on composite material properties is studied, and then natural frequency control is performed by plate topology optimization method. The results of this study are as followed. 1) Programs that calculate material properties along it's microstructure composition and control natural frequency on composite material plate are coded by Homogenization and Topology Optimization method. and it is examined by example problem. 2) Equivalent material properties, calculated by program, are examined for natural frequency. In this paper, Suggested programs are coded using $Matlab^{TM}$, Feapmax and Feap Library with Homogenization and Topology Optimization method. and Adequacy of them is reviewed by performing the maximization or minimization of natural frequency for plates with isotropic or anisotropic materials. Since the programs has been designed for widely use. If the mechanism between composite material and other structural member is identified, extension application may be possible in field of structure maintenance, reinforcement etc. through application of composite material.

Comparison of Track Vibration Characteristics for Domestic Railway Tracks in the Aspect of Rolling Noise (철도 전동 소음의 관점에서 해석한 국내 철도의 진동 특성 비교)

  • Ryue, Jungsoo;Jang, Seungho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • An important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. The main contributors to rolling noise are the sleepers, rail, and wheels. In order to analyze and predict rolling noise, it is necessary to understand the vibrating behaviors of railway tracks, as well as of the wheels. In the present paper, theoretical modeling methods for railway track are reviewed in terms of rolling noise; these methods are applied for the three representative types of domestic railway tracks operated: the conventional ballasted track, KTX ballasted track and KTX concrete track. The characteristics of waves propagating along rails are investigated and compared among the types of tracks. The tracks are modeled as discretely supported Timoshenko beams and are compared in terms of the averaged squared amplitude of velocity, which is directly related to the sound radiation from the rails.

Instantaneous Environmental Noise Simulation of High-speed Train by Quasi-stationary Analysis (준정적 해석을 이용한 고속 열차의 순간 환경소음 시뮬레이션)

  • Cho, Dae-Seung;Kim, Jin-Hyeong;Choi, Sung-Won;Chung, Hong-Gu;Sung, Hye-Min;Jang, Seung-Ho;Koh, Hyo-In
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.1003-1009
    • /
    • 2012
  • An instantaneous environmental noise simulation method emitted by a moving high-speed train by quasi-stationary analysis is proposed in this study. In the method, the propagation attenuations from stationary point sources on segmented railways to a receiver are calculated using a general purpose environmental noise prediction program ENPro based on the ISO 9613-2 method. Then, the instantaneous environmental noise at a receiver due to a moving high-speed train considering convection effect is evaluated with the information on the propagation attenuations from the instantaneous train location to the receiver and the sound power levels and directivity of stationary point sources evaluated by German Schall 03 (2006). To demonstrate the validity of proposed method, simulated and measured time history of instantaneous noise for KTX-I and KTX-II on running are compared and the results show that the method can be utilized for the train noise source identification as well as the simulation of instantaneous environmental noise emitted by a high-speed train.

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.