• Title/Summary/Keyword: solvent engineering

Search Result 2,161, Processing Time 0.024 seconds

Evaluation of the Efficiency of Solvent Systems to Remove Acetic Acid Derived from Pre-pulping Extraction

  • Park, Seong-Jik;Moon, Joon-Kwan;Um, Byung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.447-455
    • /
    • 2013
  • Hemicellulose extract obtained by pre-pulping extraction of woodchips, is very diluted acidic in nature. The major component responsible for this weak acidity is acetic acid, present in levels up to 5~10 g/L. Here, we report an exploratory study on the extract upgrading by reactive solvent extraction of acetic acid as well as ASPEN simulation. In this study, liquid-liquid equilibria for the ternary systems (water + acetic acid + ethyl acetate) were measured at the temperature of 298.15 K and 10 (pH = 2.02), 5 (pH = 2.17), and 1 (pH = 2.48) percent of acetic acid samples were used to carry out liquid-liquid extraction studies using ethyl acetate. In a one-stage batch experiment, 96.0% of acetic acid could be extracted for the solvent when the ratio of organic-to-aqueous phases is 4:1. For simulation results, they were used to estimate the interaction parameters between each of the three compounds of the systems studied for the NRTL and UNIQUAC models. The estimated interaction parameters were successfully used to predict the equilibrium compositions by the two models.

Recovery of Nickel and Cobalt by a Hydrometallurgical Process from Nickel Laterite Ore with High Magnesium Content (마그네슘함량이 높은 니켈 laterite광으로부터 습식공정에 의한 니켈과 코발트 회수)

  • Lee, Manseung;Kim, Sangbae;Choi, Youngyun;Chae, Jonggwee
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.62-70
    • /
    • 2010
  • Leaching and solvent extraction experiments have been performed to develop a hydrometallurgical process for the recovery of nickel and cobalt from nickel laterite ore with high magnesium content. Most of the nickel and magnesium in the laterite ore dissolved at leaching conditions of $80^{\circ}C$ and 100 g/L sulfuric acid concentration. while half of the cobalt and iron were leached at the same conditions. Solvent extraction experiments were carried out with D2EHPA and saponifed D2EHPA from a synthetic solution containing Ni, Co, and Mg. The extraction percentage of Co, Mg. and Ni by D2EHPA was very low in a pH range of 4.4 to 7.3. while the extraction percentage sharply increased by using saponified D2EHPA. The stripping percentage of the metals from the saponified D2EHPA increased with sulfuric acid concentration and reached 99.9% at 1 M $H_2SO_4$ solution.

Kinetic and Thermodynamic Analysis of AChE Inhibition of Solvent Extract Fractions from Inonotus obliquus (차가버섯 용매추출분획의 Acetylcholinesterase 저해활성에 대한 동역학 및 열역학적 해석)

  • Kim, Hak-Kyu;Hur, Won;Hong, Eok Kee;Lee, Shin-Young
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.289-296
    • /
    • 2011
  • Twenty four fractions by solvent extraction and/or acid precipitation from fruit body and culture broth of Inonotus obliquus were prepared, and their inhibitory effect against acetylcholinesterase (AChE) was investigated. Among these fractions, acid (1 M HCl) precipitates from cell-free culture broth and fruit body exhibited the highest inhibitory effect on AChE in vitro. Acid precipitates inhibited AChE activity in a concentration-dependant manner and $IC_{50}$ values of both acid precipitates were 0.53 mg/mL. The inhibition pattern was general non-competitive inhibition. The energetic parameters were also determined by dual substrate/temperature design. Both acid precipitates increased the values of Ea, ${\Delta}H,/;{\Delta}G$ and ${\Delta}H^{\ast}$ decreasing the value of ${\Delta}S$ for AChE. The results implied that the acid precipitates from I. obliquus increased the thermodynamic barrier, leading to the breakdown of ES complex and the formation of products as inhibitory mechanism.

Fabrication and Characteristics of Non-Solvent Silica-Acryl Monomer Hybrid Sol for Optical Device (광학용 무용제 실리카-아크릴 모노머 하이브리드 졸 기반의 코팅액 제조 및 특성 평가)

  • Kang, Woo Kyu;Jang, Gun Eik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.246-251
    • /
    • 2019
  • A solvent free, highly concentrated silica-acryl monomer hybrid sol was synthesized using aqueous colloidal silica as a precursor. The effects of the silica particle size, type of surface treatment agent employed, and silica content on the formation of the hybrid sol were systematically studied. The optical and physical properties of the coating solution prepared using the hybrid sol were also characterized. The viscosity of the hybrid sol tended to decrease as the particle size of the silica and the molecular weight of the surface treatment agent increased. The PET substrate coated with MPTMS-Mix (mixture, 70 wt%) solution showed the highest surface hardness (6 H) and low surface roughness ($Ra=0.044{\mu}m$), which could be attributed to an increase in packing density caused by the infiltration of small particles into the pores formed between larger particles.

Solvent Extraction of Rhodium(III) and Iridium(IV) from Hydrochloric Acid Solution (염산용액에서 로듐(III)과 이리듐(IV)의 용매추출)

  • Lee, Maseung;Lee, Jinyoung;Sun, Panpan
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.5
    • /
    • pp.430-435
    • /
    • 2010
  • Solvent extraction experiments of Rh(III) and Ir(IV) were performed on the HCl solution by using Alamine336 and TBP. The extraction percentage of Rh and Ir by Alamine336 was much higher than that by TBP. For the solvent extraction with Alamine336, the extraction percentage of Rh and Ir decreased with a HCl concentration. However, the extraction percentage of both metals by TBP was below 12% in our experimental range and increased with an increasing HCl concentration of up to 8 M. From the mixed solution of Ir with an excess SnCl$_{2}$, most of the tin was extracted by Alamine336 and TBP. However, the extraction percentage of Ir by Alamine336 was reduced and no iridium was extracted by TBP. The extraction behavior of Ir and Sn was investigated by scrubbing experiments on the loaded Ir with a SnCl$_{2}$ solution.

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

Characterization and Preparation of Polyimide Copolymer Membranes by Non-Solvent Induced Phase Separation Method (비용매 유도 상전이법을 이용한 공중합체 폴리이미드 분리막의 제조 및 특성평가)

  • Lee, Jung Moo;Park, Jeong Ho;Kim, Deuk Ju;Lee, Myung Gun;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.25 no.4
    • /
    • pp.343-351
    • /
    • 2015
  • In this study, we synthesis polyimide with high gas selectivity using 2,2-bis(3,4-carboxylphenyl) hexafluoropropane, 2,4,6-Trimethyl-1,3-phenylenediamine (DAM) and 4,4-Methylenedianiline (p-MDA), and then the asymmetric membrane was fabricated by non-solvent phase separation method. To confirm the property change of the membrane using different solvent, we measured and compared the viscosity of the polymer solution, cloud point and non-solvent phase separation coefficient. The morphology and gas separation property of membrane prepared by phase separation method was confirmed using Field Emission Scanning Electron Microsope and the single gas permeation measurement apparatus. The single gas ($CH_4$, $N_2$, $O_2$, $CO_2$) permeation property and selectivity value of the membrane prepared with NMP was higher than the membrane prepared with DMAc. We confirmed that the gas selectivity of the membrane increased and the permeation property decreased with increasing of the solvent evaporation time.

Investigation of Solvent Effect on the Electrical Properties of Triisopropylsilylethynyl(TIPS) Pentacene Organic Thin-film Transistors (용제에 따른 TIPS(triisopropylsilyl) Pentacene을 이용한 유기박막 트렌지스터의 전기적 특성에 관한 연구)

  • Kim, K.S.;Kim, Y.H.;Han, J.-In;Choi, K.N.;Kwak, S.K.;Kim, D.S.;Chung, K.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.435-441
    • /
    • 2008
  • In this paper, we investigated the electrical properties of triisopropylsilyl (TIPS) pentacene organic thin-film transistor (OTFT) depending on solvent type. We spin coated TIPS pentacene by using chlorobenzene, p-xylene, chloroform, and toluene as solvents. Fabricated OTFT with chlorobenzene shows field-effect mobility of $1.0{\times}10^{-2}cm^2/V{\cdot}s$, on/off ratio of $4.3{\times}10^3$ and threshold voltage of 5.5 V. In contrast, with chloroform, the mobility is $5.8{\times}10^{-7}cm^2/V{\cdot}s$, on/off ratio of $1.1{\times}10^2$ and threshold voltage of 1.7 V. Moreover we measured the grain size of each TIPS pentacene solvent by atomic force microscopy (AFM). From these results, it can be concluded that a solvent with higher boiling point results in better electrical characteristics due to large grain size and high crystallinity of TIPS pentacene layer. In this paper TIPS pentacene with chlorobenzene shows the best electrical properties.

A Study on the Electrochemical Properties of Porous Carbon Electrode according to the Organic Solvent Contents (유기용매의 함량비에 따른 다공성 탄소전극의 전기화학적 특성 연구)

  • Lim, Jung-Ae;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.185-190
    • /
    • 2008
  • In order to increase the surface area of electrodes for electrosorption, porous carbon electrodes were fabricated by a wet phase inversion method. A carbon slurry consisting of a mixture of activated carbon powder (ACP), polyvinylidene fluoride (PVdF), and N-methyl-2-pyrrolidone (NMP) as a solvent was cast directly on a graphite sheet. The cast film was then immersed in pure water for phase inversion. The physical and electrochemical properties of the electrodes were investigated using scanning electron microscopy (SEM), porosimetry, and cyclic voltammetry. The SEM images verified that the pores of various sizes were formed uniformly on the electrode surface. The average pore sizes determined for the electrodes fabricated with various NMP contents ranged from 64.2 to 82.4 nm and the size increased as the NMP content increased. All of the voltammograms showed a typical behavior of charging and discharging characteristic at the electric double layer. The electrical capacitance ranged from 3.88 to $5.87F/cm^2$ depending on the NMP contents, and the electrical capacitance increased as the solvent content decreased. The experimental results showed that the solvent content is an important variable controlling pore size and ultimately the capacitance of the electrode.

Quantitative Extraction Analysis of Brominated Flame Retardant Substances Using Supercritical-Fluid Method for Environmental Assessment (초임계추출법을 이용한 브롬계 난연제 화합물 환경성 평가 추출효율 분석 연구)

  • Oh, Min-Kyung;Yoon, Sang-Hwa;Lee, Young-Kwan;Han, Jae-Sung;Won, Sung-Ho;Nam, Jae-Do
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • For the evaluation of brominated flame retardants included in polymeric electronic devices, we investigated the extraction methods and solvent systems for four different types of polymers of PC (polycarbonate), PP (polyropylene), PET (poly(ethylene terephthalate)) and PBT (poly(butylene terephthalate)) using different solvent systems of hexane/acetone, THF, toluene, and THF/toluene. In order to compare the extraction efficiency of different methods and solvent systems, the deca-BDE (decabromo diphenyl ether) flame retardant was included in PC, PP, PET and PBT systems and subsequently extracted by soxhlet, ultrasonic, accelerated solvent, microwave and supercritical fluid extraction methods. The amount of the extracted flame retardant was monitored to evaluate the extraction efficiency. The ultrasonic extraction method was found not to be acceptable as an extraction method for the polymer systems mainly due to a low salvation efficiency of the organic solvents. Soxhlet, accelerated solvent and microwave extraction methods exhibited over 80% of extraction efficiency for toluene. The supercritical fluid extraction method, which has been used as an extraction method for flame retardants in polymers, showed the extraction efficiencies of ca. 100% for PC and PP in the optimal extraction conditions of $60^{\circ}C$ and 120 bar.