• 제목/요약/키워드: solar tower

검색결과 89건 처리시간 0.024초

설마천 유역 CO2 Flux 실측 자료에 의한 총일차생산성 (GPP)과 MODIS GPP간의 비교 평가 (Evaluation of MODIS Gross Primary Production (GPP) by Comparing with GPP from CO2 Flux Data Measured in a Mixed Forest Area)

  • 정충길;신형진;박민지;조형경;김성준
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.1-8
    • /
    • 2011
  • In this study, In order to evaluate reliable of MODIS GPP, the MODIS GPP and Flux tower measured GPP were compared to evaluate the use of method on 8 days composite MODIS GPP. The 2008 Flux data ($CO_2$ Flux and air temperature) measured in Seolmacheon watershed ($8.48\;km^2$) were used. The Flux tower GPP was estimated as the sum of $CO_2$ Flux and $R_{ec}$ (ecosystem respiration) by Lloyd and Taylor method (1994). The summer Monsoon period from June to August mostly contributed the underestimation of MODIS GPP by cloud contamination on MODIS pixels. The 2008 MODIS GPP and Flux tower GPP of the watershed were $1133.2\;g/m^2/year$ and $1464.3\;g/m^2/year$ respectively and the determination coefficient ($R^2$) after correction of cloud-originated errors was 0.74 (0.63 before correction). Even though effect of Cloud-Originated Errors was eliminated, Solar radiation and Temperature are affected at GPP. Measurement of correct GPP is difficult. But, If errors of MODIS GPP analyze on Cloud Moonsoon Climate in korea and eliminated effect of Cloud-Originated Errors, MODIS GPP will be considered GPP increasing of 9 %. There, Our results indicate that MODIS GPP show reliable and useful data except for summer period in Moonsoon Climate.

고온 태양열 공기식 흡수기의 충진재 변화에 따른 열전달 및 압력강하 성능 분석 (Honeycomb and Laminated Mesh as Open Volumetric Solar Receiver : Performance of Heat Transfer and Pressure Drop)

  • 조자현;이주한;강경문;서태범
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.760-766
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop of several different porous materials which can be used as inserts inside solar volumetric air receivers were experimentally investigated. Generally, porous materials were inserted into solar volumetric air receivers to increase the thermal performance. In the present work, honeycomb (diameter: 100 mm, thickness: 30 mm), laminated mesh (diameter: 100 mm, thickness: 1 mm) are considered as the inserts for the experiment. The experimental apparatus consists mainly of a cylindrical ceramic duct as a receiver and an electric heater as an energy source. This system is an intake open loop, which used as air of working fluid. The temperatures inside the ceramic tube are measured by thermocouples, which are installed at each layer of the porous materials. The pressure-drop experimental apparatus is fabricated alike the above experimental equipment. An acrylic tube is used like as the ceramic tube, which has the same specifications of the ceramic tube. The pressure drop of porous materials inserted in the acrylic tube is measured between front and rear of those by transmitter. The results show that the laminated mesh surpasses the honeycomb of heat transfer and pressure drop increase as the porous material thickness and Reynolds number.

공동주택의 입면 변화에 따른 일조 현황 분석 - Skyline 변화를 중심으로 - (Analysis of the Daylight Condition on Facade Variation in Apartment Housing)

  • 이덕형;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.79-86
    • /
    • 2006
  • As a factor of housing environment, right of light became a subject of discussion as a social issue. Cases on the right of light in properties have been increased. Also many interests in the scape of the city have been increased. This study aims to show the possibility of variation of the shape of the apartment buildings considering the right of light. Reflecting this recent situation, we are setting up the night illumination and constructing a building which acts as Land Mark like the Jong-Ro Tower. And In case of the apartment building, various forms are deviated from an existing standardized form and skyline Existing studies on the sunshine of apartment buildings have dealt with just a standardized apartment building form. So this study analyzed a recently increasing interest for right of light and the changes of sunshine environment of apartment buildings having various forms of skyline.

중국 1 MWe급 태양열발전시스템에 대한 기초 운전해석 (Preliminary Simulation Study on 1 MWe STP System in China)

  • ;;강용혁;김종규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.698-701
    • /
    • 2007
  • DAHAN, the first 1 MWe Solar Power Tower system locates north to Beijing where nearby The Great Wall is now under construction with cooperation between China and Korea. Results in predicting the preliminary performance of this central receiver system are presented in this paper. Operating cycles under some typical weather condition days are simulated and commented. These results can be used to assess the impact of alternative plant designs or operating strategies on annual energy production, with the final objective being to optimize the design of central receiver power plants. Two subsystems are considered in the system simulation: the solar field and the power block. Mathematic models are used to represent physical phenomena and relationships so that the characteristics of physical processes involving these phenomena can be predicted. Decisions regarding the best position for locating heliostats relative to the receiver and how high to place the receiver above the field constitute a multifaceted problem. Four different kinds of field layout are designed and analyzed by the use of ray tracing and mathematical simulation techniques to determine the overall optical performance ${\eta}_{field}$ and the spillage ${\eta}_{spill}$.The power block including a Rankine cycle is analyzed by conventional energy balance methods.

  • PDF

NREL 5MW 풍력터빈의 제어시스템 설계 (Control System Design of NREL 5MW Wind Turbine)

  • 남윤수;임창희
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.31-40
    • /
    • 2012
  • This paper introduces a methodology for NREL 5MW wind turbine, which is the variable speed and variable pitch(VSVP) control system. This control strategy maximizes the power extraction capability from the wind in the low wind speed region and regulates the wind turbine power as the rated one for the high wind speed region. Also, pitch control efficiency is raised by using pitch scheduling.Torque schedule is made of torque table depending on the rotor speed. Torque control is used for vertical region in a torque-rotor speed chart. In addition to these, mechanical loads reduction using a drive train damper and exclusion zone on a torque schedule is tried. The NREL 5MW wind turbine control strategy is comprised by the generator torque and blade pitch control. Finally, proposed control system is verified through GH Bladed simulation.

높이별 기상변화를 고려한 초고층 건축물의 외피종류별 냉난방 부하특성 분석 (Effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height)

  • 최종규;김양수;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.337-344
    • /
    • 2012
  • Today, the number of super tall buildings are under construction or being planed in Middle East and Asian Countries. For example the burj Khalifa, the tallest building in the world, is completed in 2008 and the height of that is about 800m. Also, Lotte World Tower is under construction in Korea. External environmental conditions such as wind speed, air temperature, humidity and solar radiation around the super tall building differs according to the building height due to the vertical micro climate change. However, the meteorological information used for AC design of building is obtained typically from standard surface meterological station data(~2m above the ground). In this paper the effect of the building envelope on heating and cooling load in super tall building considering the meteorological changes with height was analyzed with simulation method. As results of this research, the guideline to select the building envelop alternatives for super tall building will be suggested in this paper.

  • PDF

IEC 61400 풍력표준을 적용한 제주도 김녕 난류강도 특성분석 (Analysis on Turbulence Intensity Characteristics at Gimnyeong, Jejudo by Applying IEC 61400 Wind Turbine Standards)

  • 김현구;정태윤;장문석
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.59-65
    • /
    • 2010
  • Analysis on turbulence intensity profile depending on wind speed is an important process to set up design condition of wind turbine in terms of fatigue load. This paper tests goodness of fit of turbulence intensity empirical equations suggested by the IEC 61400 Standards with Jejudo Gimnyeong met-tower measurement, which is erected at a seashore. Therefore sea breeze and land breeze coexist. Sea breeze case showed apparent increasing trend of turbulence intensity in a high wind speed regime due to increase of sea surface roughness. However, neither inland wind turbine standard IEC 61400-1 nor offshore wind turbine standard IEC 61400-3 fit such a trend adequately. On the other hand, the modified empirical equation of turbulence intensity of IEC 61400-3 derived from Germany FINO1 application study by considering turbulence intensity behavior in a high wind speed regime showed good agreement with the measurement. Therefore, we can reconfirm and conclude that IEC 61400-3 Ed.1 legislated in 2009 needs to be modified.

2MW급 해상용 영구자석 직접 구동형 풍력 발전기의 정상상태 특성 해석 (The Steady-State Characteristic Analysis of 2MW PMSG based Direct-Drive Offshore Wind Turbine)

  • 신평호;최정철;유철;김대진;경남호;고희상
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.9-16
    • /
    • 2015
  • In order to support various studies for assessment of onshore and offshore wind turbine system including foundations, the land-based version of 2MW PMSG direct drive wind turbine has been analyzed using HAWC2 that account for the coupled dynamics of the wind inflow, elasticity, and controls of the turbine. this work presents the steady-state response of the system and natural frequency of the first thirteen structure turbine modes as a function of wind speed. Rotor, generator speeds, pitch angle, power production, thrust force, deflections of tower and blade are compared for one case below and one case above the rated wind speed.

SEBAL 모형과 Terra MODIS 영상을 이용한 혼효림, 논 지역에서의 공간증발산량 산정 연구 (Estimation of spatial evapotranspiration using Terra MODIS satellite image and SEBAL model in mixed forest and rice paddy area)

  • 이용관;정충길;안소라;김성준
    • 한국수자원학회논문집
    • /
    • 제49권3호
    • /
    • pp.227-239
    • /
    • 2016
  • 본 연구는 Surface Energy Balance Algorithm for Land (SEBAL) 모형을 이용해 국내의 혼효림(설마천)과 논(청미천) 유역에 대해 일 증발산량을 산정하고 각 유역의 플럭스 타워 실측 증발산량과 비교하였다. SEBAL 모형의 입력 자료로 위성자료는 2개년(2012-2013)의 Terra MODIS product 중 Albedo, Land Surface Temperature (LST), Normalized Difference Vegetation Index (NDVI)를 활용하였으며, 기상자료는 유역 인근에 위치한 기상청 기상관측소로부터 풍속, 일사량 자료를 제공받아 공간 내삽(Interpolation)하여 활용하였다. 모의결과 플럭스 타워의 연평균 증발산량은 설마천에서 302.8 mm, 청미천에서 482.0 mm, SEBAL 모의 증발산량은 각각 183.3 mm, 371.5 mm로 산정되었다. 전체 모의기간에 대한 SEBAL 모의 증발산량의 실측 증발산량과의 결정계수는 설마천 플럭스 타워에서 0.54, 청미천 플럭스 타워에서 0.79로 나타났다. 두지점에서 SEBAL 모의 증발산량이 과소 추정된 주된 이유로는 일별 hot pixel과 cold pixel로부터 산정한 현열 플럭스의 과대추정으로 인한 것으로 판단된다.

Multitasking Façade: How to Combine BIPV with Passive Solar Mitigation Strategies in a High-Rise Curtain Wall System

  • Betancur, Juan
    • 국제초고층학회논문집
    • /
    • 제6권4호
    • /
    • pp.307-313
    • /
    • 2017
  • This paper outlines the processes and strategies studied and selected by the team during the design stages of the project for the incorporation of BIPV into the tower's façade. The goal was to create a system that helps reduce internal heating and cooling loads while collecting energy through photovoltaic panels located throughout the building. The process used to develop this façade system can be broken down into three stages. 1. Concept: BIPV as design catalyst for a high-rise building. 2. Optimization: Balancing BIPV and Human comfort. 3. Integration: Incorporating BIPV into a custom curtain wall design. The FKI Project clearly illustrates the evolution building enclosures from simple wall systems to high performance integrated architectural and engineering design solutions. This design process and execution of this project represent the design philosophy of our firm.