• 제목/요약/키워드: solar collector

검색결과 442건 처리시간 0.028초

아파트 적용 태양열 난방 및 급탕시스템의 열적 거동에 관한 실험연구 (Experimental Study on the Thermal Behavior of Solar Space Heating & Hot Water System in Apartment)

  • 신우철;백남춘;김종현
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.127-134
    • /
    • 2006
  • In this paper, an experiment was carried out to investigate the thermal behavior and performance on a solar space heating & hot water system in an apartment. Measurement was continued for 6 months between January 1st 2004 and June 31th 2004. The results show that there is no problem in control and operation in case of connection this system with conventional space heating and hot water system, and that the thermal performance of this system and indoor thermal environment is good.

밀폐형 유동층을 이용한 태양광 고온가스가열 장치의 연구 (High Temperature Solar Gas Heating by a Compact Fluidized-Bed Receiver of Closed-Type)

  • 최준섭
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.88-94
    • /
    • 1992
  • 태양광 고온가스가열 장치를 위하여 후레넬렌즈면적 $0.5m^2$을 갖는 소형태양집열 및 추적시스템과 고급의 소형 밀폐형 유동층 태양광 수열기를 개발하였다. 개발된 태양광 수열기는 개방형 유동층의 단점인 SiC입자의 유출과 열사이폰효과를 개선하였다. 공기의 최대 도달온도는 1140K이며, 최대 열효율은 64%얻어졌다. 본 연구에서 개발한 태양광수열기는 기존의 평판이나 관형의 고체표면을 갖는 태양 집열기와 비교할 때 아주 고온에서 효율 좋게 작동된다.

  • PDF

9 kW 출력용 태양열 스털링엔진 발전시스템의 설계와 성능예측 (Design and Performance Prediction of Power System in a Solar Stirling Engine for 9 kW Output)

  • 배명환;강상율
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2198-2204
    • /
    • 2003
  • In order to make a match of the insufficient direct solar radiation, in this study, the target output is lowered to 9 kW smaller than 25 kW in former studies. It is also necessary to match the collector/receiver with engine/generator systems to accomplish the power level of a system. The simulation analyses of a dish solar power system with stirling engine are totally carried out to predict the system performance with the designed values. In addition, an influence of direct solar radiation on system performance and operation control is discussed in simulation. It is found that the diameter of concentrator could be made small to 8 m regardless of slope errors with 2.5 and 5.0 mrad radiation, and the operation range of mean pressure control. is wide even if the direct solar radiation is a quit low.

  • PDF

다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 - (A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system -)

  • 남보현
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

태양열 이용 해양온도차발전시스템의 성능 예측 (Performance Investigation of Solar-Heating Ocean Thermal Energy Conversion (SH-OTEC) in Korea)

  • ;이근식
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.43-49
    • /
    • 2013
  • 전력을 생산하기 위해 해양온도차발전을 이용하는 것은 재생에너지를 이용하고 환경을 보호하는 한 가지 방법이다. 본 연구에서는 울산지역의 기후조건이 태양열 이용 해양온도차발전(SH-OTEC)에 미치는 영향을 조사하기 위하여 시뮬레이션을 수행하였다. 태양열 에너지는 제 2 의 열원으로 사용되었다. SH-OTEC 시스템에 사용할 가장 적합한 작동유체를 선정하기 위하여 여러 작동유체를 수치모사하였다. 해석결과, R152A 가 가장 적합한 작동유체로 나타났으며, R600 와 R600A 가 각각 그 다음 순으로 나타났다. 집열판 출구온도를 $20^{\circ}C$ 증가하였을 때 집열판의 유효면적은 월평균 태양에너지 게인(gain)의 변화로 인하여 $50m^2$ 에서 $97m^2$ 으로 요동함을 볼 수 있었다. 2-4%의 전형적인 해양온도차발전의 효율은 태양열을 이용함으로써 연평균 효율은 6.23%까지 증가하였다.

동적 시뮬레이션을 이용한 태양광열 시스템의 성능특성 분석 (Study on the Analysis Performance of PVT system using the Dynamic Simulation)

  • 김상열;남유진
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: A photovoltaic/thermal system is a solar collector combining photovoltaic module with a solar thermal collector, which produces electricity and heat at the same time. PVT system removes heat from PV module through air or liquid that would help to raise the efficiency of the PV systems performance. Many innovative systems and products have been put forward and their quality evaluated by academics and professionals. However, even though various of PVT system were developed and several systems were applied to practical use, there have been few researches for the performance analysis using the dynamic simulation. Method: In this study, the review of recent research and development trend for PVT systems were conducted. Furthermore, in order to develop the optimum design method, the performance analysis for PVT system was conducted by a dynamic simulation. Result: In the results, it was found that the performance of PVT system significantly depends on the ambient temperature and solar radiation. Moreover, in the weather condition of Seoul, average efficiency of electricity and heat in heating season were 13.79 and 41.85%, and they in cooling season were 14.39% and 26.18%, respectively.

다중 파라볼릭 반사경 방식을 이용한 추적식 집광시스템 개발 (Development of Tracking Daylighting System Using Multi-Parabolic Reflector)

  • 이충식;김종민;박연민;성태경;정채봉;강승훈;김병철
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.56-63
    • /
    • 2013
  • Daylighting system is an alternative lighting system using daylight collecting device, light transformer and light diffuser. In this paper, we developed a daylighting system in which the collecting device composed by dual parabolic reflectors, the silica optical fiber adapted to the light transformer and light diffuser made of the polyglass square sheet. We have estimated the system efficiency and general color rendering index(Ra) of the developed system. The system efficiency measured to 23.8% and Ra was revealed as 95. Ra number of the developed system is bigger than the number(65) of the previous fresnel lens based sunlight collector.

액체식 Glazed PVT 복합모듈의 성능실험 연구 (An Experimental Study of a Water Type Glazed PV/Thermal Combined Collector Module)

  • 김진희;김준태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.260-265
    • /
    • 2008
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic/thermal (PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that converts solar radiation into electricity and heat simultaneously. In general, two types of PVT can be distinguished : glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively low-temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of water type PVT combined module, glass-covered, analyzed. The electrical and thermal performance of the module were measured in outdoor conditions, and the results are analyzed. The results showed that the thermal efficiency of the PVT module was 27.6% average and its PV efficiency was about 10.0% average, both depending on solar radiation, inlet water temperature and ambient temperature.

파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I) (An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section)

  • 이종호;정모;백남춘;오정무
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF