• Title/Summary/Keyword: solar collector

Search Result 442, Processing Time 0.024 seconds

Solar Air Heating System Thermal Performance Simulation and Verification (태양열 외기 난방 시스템의 열성능 시뮬레이션 및 검증 연구)

  • Kang, Dong-Un;Lee, Euy-Joon;Hyun, Myung-Taek
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.152-157
    • /
    • 2001
  • UTC(Unglazed Transpired Collector) system has recently emerged as a new solar air heating technology. It is relatively inexpensive because it has not a glazed material. And it demonstrates efficient particularly for the applications in which larger wall area facilities with a high outdoor air requirement. Mathematical algorithm for UTC thermal modeling has been understood for further improvement of the system. EES and TRNSYS model of actual solar wall panel could be developed for computer simulations under other conditions. Computer models could be validated with the measured data from fixed outdoor test cell in KIER(Korea Institute of Energy Research). Major design parameters could be identified such as panel configuration and absorptivity and emissivity values for UTC design.

  • PDF

The Development of a Computer Simulation Model for Solar Space Heating System Analysis (태양열 난방시스템 해석을 위한 전산시뮬레이션 모델의 개발)

  • Lee Y. S.;Seoh J. I.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.1
    • /
    • pp.63-73
    • /
    • 1987
  • This research, through the analysis of existing programs, presents a simplified logical program which can show the thermal performance of a system, based only on hourly weather data and the system design data. This program is applicable for analyzing a system of direct heating or recirculation heating which may enhance the performance of an existing solar house. Using these system in the existing systems a little raise in performance. The model analysis of a $100\;m^2$ solar house in the seoul region shows that the following figures are the most efficient and suitable; 1. Installation an81e of collector: $45^{\circ}$ 2. Collector size: $34.56\;m^2$ 3. Capacity of main storage tank: $25\;m^3$

  • PDF

Performance Prediction of a Solar Power System with Stirling Engine in Different Test Sites (설치장소에 의한 스털링엔진 태양열 발전시스템의 성능예측)

  • Kazuo Tsuchiya
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.122-128
    • /
    • 2001
  • The simulation analyses of a dish solar power system with stirling engine in this study are applied to system performance prediction if four different test sites; Seoul, Pusan and Cheju in Korea, and Naha in Japan. The effects of difference of concentrator type such as monolithic and stretched-membrane construction on system efficiency are also evaluated. The total amount of generated power for a year depends on the site. However the total maximum system efficiency in every site is approximately 16% and there isnt striking difference. It is also found that the maximum collector efficiency of stretched-membrane concentrator is about 3∼15% lower than that of the monolithic type.

  • PDF

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

State of Arts on the Performance of Collector (집열기 성능향상에 관한 연구현황)

  • Lee, Jong-Ho;Lee, Jin-Kook
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.75-86
    • /
    • 1987
  • In this research, we have analyzed the researches and productions of solar collectors in Korea and U.S.A. In the U.S., collectors are produced by hundreds of manufacturers. The amounts are 23 million sq.ft for the liquid system, 358 thousand sq.ft of the air system and 266 thousand sq.ft for the vacuum tube and focus collectors. In Korea, a very small quantity is produced by several manufacturers. So they have to be largely dependent upon the imports in Korea. In the U.S., research topics include the materials development, design and applications. In Korea, however materials research has been rare and there have been only a few papers on selective coating. Researches have been limited to the system design and collector testing.

  • PDF

Design and Preliminary Performance Test for 5kWt Dish Solar Collector ($5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Han, Gui-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

Experimental Study of a Solar Drying System (태양열 건조시스템의 실험적 연구 (I))

  • Lee, K.D.;Lee, N.H.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.14-22
    • /
    • 1987
  • This paper presents an experimental study of a solar drying system designed and installed by KIER. Experiments have been performed using the KIER system for the drying of marine products, such as squid. Presented in detail are the experimental observations of collector air temperature, solar intensity, absorber plate temperature, drying chamber temperature, humidity and other measures of drying chamber performance with variation of air mass flow rate. As a result, average temperature attained in the drying chamber during autumn weather has been adequated for drying of squids.

  • PDF

Numerical Study on the Flow Distribution Characteristics with Varying Inlet Flow-Rate in Mega Collector Risers (입구 유량변화에 따른 메가 집열기 지관의 유량분포특성에 대한 수치해석)

  • Kim, Hwi-Dong;Baek, Nam-Choon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.150-154
    • /
    • 2009
  • Flow distribution characteristics with varying inlet flow-rate in mega collector risers have been investigated, using commercial code FLUENT. The heat transfer in mega collector was not considered in this numerical study. Through the simulation, the following results were found. First, flow distribution characteristics in mega collector risers show the similar tendency in all cases. Secondly, with increased inlet flow-rate, flow distribution uniformity was getting worse.

  • PDF

Evaluation of seasonal performance for single-stage desalination system with solar energy (1단 증발식 해수담수화 시스템의 계절별 성능 평가)

  • Kwak, Hee-Youl;Joo, Hong-Jin;Joo, Moon-Chang;Kim, Jung-Bae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.221-226
    • /
    • 2008
  • This study was carry out evaluation of seasonal performance for the decentralized desalination system with the solar thermal system and the photovoltaic power system. First operating demonstration system was set up in Cheju in 2006. These system comprises the desalination unit with designed daily fresh water capacity of $2m^3$ and is supplied by a $120m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation supply the electricity for hydraulic pumps to move the working fluids. In a spring season day average $392W/m^2$, the daily fresh water showed to produce about 340liter. In a summer season day average $296W/m^2$, the daily fresh water showed to produce about 328liter. In a autumn season day average $349W/m^2$, the daily fresh water showed to produce about 277liter. In a winter season day average $342W/m^2$, the daily fresh water showed to produce about 271liter.

  • PDF

Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector (태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구)

  • Woo, Jong-Soo;Choi, Kwang-Hwan;Yoon, Jeong-In
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.