• Title/Summary/Keyword: soil model

Search Result 4,496, Processing Time 0.036 seconds

A Study on Estimation of the Delivery Ratio by Flow Duration in a Small-Scale Test Bed for Managing TMDL in Nakdong River (낙동강수계 수질오염총량관리를 위한 시범소유역 유황별 유달율 산정방법 연구)

  • Shon, Tae-Seok;Park, Jae-Bum;Shin, Hyun-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.792-802
    • /
    • 2009
  • The objective of this study is to construct the watershed management system with link of the non-point sources model and to estimate delivery ratio duration curves for various pollutants. For the total water pollution load management system, non-point source model should be performed with the study of the characteristic about non-point sources and loadings of non-point source and the allotment of pollutant in each area. In this study, daily flow rates and delivered pollutant loads of Nakdong river basin are simulated with modified TANK model and minimum variance unbiased estimator and SWAT model. Based on the simulation results, flow duration curves, load duration curves, and delivery ratio duration curves have been established. Then GIS analysis is performed to obtain several hydrological geomorphic characteristics such as watershed area, stream length, watershed slope and runoff curve number. As a result, the SWAT simulation results show good agreements in terms of discharge, BOD, TN, TP but for more exact simulation should be kept studying about variables and parameters which are needed for simulation. And as a result of the characteristic discharges, pollutants loading with the runoff and delivery ratios, non-point sources effects were higher than point sources effects in the small-scale test bed of Nakdong river basin.

Runoff Analysis of Urban Drainage Using DR3M-II (DR3M-II를 이용한 도시배수유역의 유출해석)

  • Min, Sang-Gi;Lee, Kil-Choon
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.9 s.158
    • /
    • pp.699-711
    • /
    • 2005
  • In this study, the U.S. Geological Survey's DR3M-II(Distributed Routing Rainfall-Runoff Model) was applied for small urban drainage. DR3M-II is a watershed model for routing storm runoff through a branched system of pipes and natural channels using rainfall input. The model was calibrated and verified using short term rainfall-runoff data collected from Sanbon basin. Also, the parameters were optimized using Rosenbrock technic. An estimated simulation error for peak discharge was about 7.4 percent and the result was quite acceptable. Results of the sensitivity analysis indicate that the percent of effective impervious area and ${\alpha}$ defining surface slope and roughness were the most sensitive variables affecting runoff volumes and peak discharge for low and high intensity storm respectively. In most cases, soil moisture accounting and infiltration parameters are the variables that give more effects to runoff volumes than peak discharge. Parameter ${\alpha}$ showed the opposite result.

Empirical ground motion model for Vrancea intermediate-depth seismic source

  • Vacareanu, Radu;Demetriu, Sorin;Lungu, Dan;Pavel, Florin;Arion, Cristian;Iancovici, Mihail;Aldea, Alexandru;Neagu, Cristian
    • Earthquakes and Structures
    • /
    • v.6 no.2
    • /
    • pp.141-161
    • /
    • 2014
  • This article presents a new generation of empirical ground motion models for the prediction of response spectral accelerations in soil conditions, specifically developed for the Vrancea intermediate-depth seismic source. The strong ground motion database from which the ground motion prediction model is derived consists of over 800 horizontal components of acceleration recorded from nine Vrancea intermediate-depth seismic events as well as from other seventeen intermediate-depth earthquakes produced in other seismically active regions in the world. Among the main features of the new ground motion model are the prediction of spectral ordinates values (besides the prediction of the peak ground acceleration), the extension of the magnitudes range applicability, the use of consistent metrics (epicentral distance) for this type of seismic source, the extension of the distance range applicability to 300 km, the partition of total standard deviation in intra- and inter-event standard deviations and the use of a national strong ground motion database more than two times larger than in the previous studies. The results suggest that this model is an improvement of the previous generation of ground motion prediction models and can be properly employed in the analysis of the seismic hazard of Romania.

A Study for Influence Range of Ground Surface due to Sewer Fracture in Various Relative Density of Sand by Laboratory Model Test (실내모형시험을 통한 상대밀도가 다양한 사질토 지반에서의 하수도관 파손에 따른 지표침하의 영향범위에 관한 연구)

  • Oh, Dong-Wook;Ahn, Ho-Yeon;Lee, Yong-Joo
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.2
    • /
    • pp.19-30
    • /
    • 2016
  • It is well known that water leakage from decrepit sewer pipe mainly causes frequent occurrence of ground subsidence in urban area. Thus, laboratory model tests were carried out to investigate ground behaviour according to location of sewer fracture and various relative densities of surrounding soil. The portion of fractured pipe was assumed to be 20% compared to the circumference of pipe, and to be positioned at the top and bottom of the pipe. Ground conditions were made as loose sand ($D_r=30%$) and dense sand ($D_r=70%$). In addition, comparison and analysis with results of model tests were carried out by Finite Element analysis. As a result, not only water leakage from the bottom of pipe (scenario 2) caused greater ground behaviour than leakage from the top of pipe (scenario 1), but also much greater surface settlement occurred when the ground condition is loose.

Analysis of the Inundation Potential by Elevation for the Land Evaluation in the Potentially Inundated Farms - A Case Study in Ibang-myeon, Changnyeong-gun, Kyungsangnamdo - (상습침수 농경지의 토지평가를 위한 고도별 침수 잠재성 분석 - 경상남도 창녕군 이방면을 대상으로 -)

  • Park In-Hwan;Jang Gab-Sue;Seo Dong-Joe
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.71-82
    • /
    • 2005
  • A large scale of riverside rearrangement has been recently done in the major rivers in Korea. So inundation possibility in agricultural area closed by these rivers has been higher than the possibility a few years ago. However, land use in this area has not been adjusted to a change of this situation near the rivers. Therefore, when typhoon or heavy rain is happened on this area, it can cause a large damage in agricultural area. This study analyzed inundation potentiality in agricultural area at Ibang-myeon, Changnyeong-gun, Kyeongnam-province, Korea by using the logistic regression model and the piecewise regression model. The first thing we did was to transfer the inundation area per elevation to the accumulated inundation area per elevation. This accumulated inundation area per elevation as an distribution function could be described by the logistic regression model(LRM), and piecewise regression model(PRM) could make it much more accurate to analyze the inundation area per elevation. As a result, the regression models derived from LRM and PRM showed $R^2$ over 0.950. The models derived from LRM and PRM in Ibang-myeon noted that frequently inundated area(FIA) was shown up to 12.12m in elevation, and potentially inundated area(PIA) was shown up to 14.60m in elevation. In FIA, regular agricultural activity would be impossible. And It would be not easy to continue the regular agricultural activity in PIA. So, this land should be rearranged to be used for a buffer zone for ecosystem protection, landscape conservation and things like that in riverside.

A Study on Ground Vehicle Mechanics for Steep Slope Forest Operations - Rubber-Tired Log Skidding Tractor Operations - (급경사지 산림작업을 위한 차량의 역학분석에 관한 연구 -차륜형 집재작업 트랙터를 중심으로-)

  • Chung, Joo Sang;Chung, Woo Dam
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.2
    • /
    • pp.218-225
    • /
    • 1995
  • In this paper, a mechanical analysis model for steep-slope log-skidding operations of a rubber-tired tractor is discussed and the applicability of the model is investigated. The model largely consists of mathematical analysis models for log drag, dynamic vehicle weight distributions and soil-vehicle traction. For the case study, a theoretical data set for log skidding operations is used in investigating the effect of the factors influencing the results of mechanical analysis or the productivity of skidding operations. The analyses include 1) the effect of log choking methods on tangential log-skidding force, 2) the effects of the change in travel speed and log load on the required input power to the wheels and 3) the log skidding performance of a two-wheel drive compared with that of a four-wheel drive.

  • PDF

Characteristics of Runoff on Urban Watershed in Jeju island, Korea (제주도 도심하천 유역의 유출특성 해석)

  • Jung, Woo-Yul;Yang, Sung-Kee;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.555-562
    • /
    • 2013
  • Jeju Island, the heaviest raining area in Korea, is a volcanic Island located at the southernmost of Korea, but most streams are of the dry due to its hydrological/geological characteristics different from those of inland areas. Therefore, there are limitations in applying the results from the mainland to the studies on stream run-off characteristics analysis and water resource analysis of Jeju Island. In this study, the SWAT(soil & water assessment tool) model is used for the Hwabuk stream watershed located east of the downtown to calculate the long-term stream run-off rate, and WMS(watershed modeling system) and HEC-HMS(hydrologic modeling system) models are used to figure out the stream run-off characteristics due to short-term heavy rainfall. As the result of SWAT modelling for the long-term rainfall-runoff model for Hwabuk stream watershed in 2008, 5.66% of the average precipitation of the entire basin was run off, with 3.47% in 2009, 8.12% in 2010, and root mean square error(RMSE) and determination coefficient($R^2$) was 496.9 and 0.87, respectively, with model efficient(ME) of 0.72. From the results of WMS and HEC-HMS models which are short-term rainfall-runoff models, unless there was a preceding rainfall, the runoff occurred only for rainfall of 40mm or greater, and the run-off duration averaged 10~14 hours.

Prediction Technique of Vibration Induced Settlement -On the Basis of Case Studies (지반 진동에 의한 주변침하 예측기법 사례 연구를 중심으로)

  • 김동수;이진선
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.103-116
    • /
    • 1996
  • Man-made vibrations from traffic and construction activities are important because they may cause damage to structures. The current literature provides that damages in the urban areas were not caused by direct transmission of vibration, but rather through subsequent settlement caused by soil densification. In this paper. prediction technique of ground borne vibration induced settlement was introduced on the basis of case studies. In situ application technique of the settlement prediction model developed in laboratary was described, and the predicted settlement was compared with the measured settlement from case studies. The settlement from case studies hlatched well with the settlement calculated from the model. The parametric studies of settlement in typical urban site conditions were performed to determine the sensitive parameters and to develop reliable vibration monitoring and interpretation schemes. These demonstrated the potential usefulness of the model for the evaluation and prediction of the vibration induced in-situ settlement of sands.

  • PDF

Fundamental Study on Oscillating Tillage -Model Test on Draft Force, Torque, Power and Moment (진동경운(振動耕耘)에 관(關)한 기초연구(基礎硏究) -견인력(牽引力), 토오크, 소요동력(所要動力) 및 모멘트에 관(關)한 모형실험(模型實驗)-)

  • Kim, Y.H.;Kim, S.T.;La, W.J.;Min, Y.B.;Lee, S.K.
    • Journal of Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 1981
  • A laboratory model test was carried out with a newly designed model to figure out the vibration characteristics of the vibratory tillage tool according to the method of forced vibration, i.e., horizontally and vertically forced vibrations. The results are summarized as follows: 1. The reduction ratios of the draft force of the vibratory blade were 14.2-42.6% for the case where the vibration was forced parallel to the travelling direction of the blade, and 15-54.5% for the vertically forced vibration. And it was thought that the method of vertically forced vibration was preferable to the reduction of the draft force. 2. The ratio of the draft force of a vibratory blade to that of a static one could be represented as a function of V/At. It was found to be possible to reduce the draft force by taking a lower value of (V/Af) and this meant that the effictiveness of tillage practice using the vibratory system would be limited. 3. The torque to the main rotating shaft to vibrate the model blade increased frequency and amplitude. This tendency varied according to the physical properties of tested soil. In case of horizontally forced vibration, the torque was 8~34% less than in case of vertically forced vibration. 4. With the increase of frequency, the total power requirement increased linearly, and also the portion of oscillating power requirement in the total power tended to increase. The magnitude of the total power requirement was 1.4-13 times greater than that of a static one for the case of horizontal vibration, and 1.5-15 times greater for the case of vertical vibration. It was thought that the horizontal vibration of the blade was preferable to the vertical vibration in view of the power requirement. 5. A linearity was found between the amplitude of moment oscillogram and magnitude of oscillating acceleration. Only positive values of moment occurred when the blade was forced to vibrate vertically, but negative values occurred in rarity in the case of amplitude A3 when the blade was forced to vibrate horizontally.

  • PDF

Comparison between the Spatially Integrated Model and the Spatially Distributed Model in the Nonpoint Source Contaminants of Groundwater (지하수 분산오염원에 대한 공간적분모형과 공간분포모형의 비교)

  • Lee, Do-Hun;Lee, Eun-Tae;Jeong, Sang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.177-187
    • /
    • 1998
  • The spatially integrated model (SIM) which can evaluate temporal variation of groundwater quality is proposed in the stream-aquifer setting entered by nonpoint source contaminants. And the developed SIM included unsaturated soil zone and was tested against the spatially distributed model (SDM) of the coupled advection-dispersion and Richards equations for the various hydrologic and aquifer simulating conditions. The result of the comparison showed that the average concentration responses of saturated aquifer and groundwater outflow between the SIM and the SDM was in good agreement, except for the case of the large dispersivity ratio and thick aquifer system. And it is shown that for the cases of the large dispersivity ratio and thick aquifer system the performance of the nonlinear SIM is better than that of the linear SIM for evaluating the average concentration of groundwater outflow response.

  • PDF