• Title/Summary/Keyword: soil model

Search Result 4,496, Processing Time 0.035 seconds

A Study on Parameter Estimation for SWAT Calibration Considering Streamflow of Long-term Drought Periods (장기 가뭄기간의 유출량을 고려한 SWAT 보정 매개변수 추정 연구)

  • Kim, Da Rae;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.2
    • /
    • pp.19-27
    • /
    • 2017
  • Recently, the hydrological model Soil Water Assessment Tool (SWAT) has been applied in many watersheds in South Korea. This study estimated parameters in SWAT for calibrating streamflow in long-term drought periods. Therefore, we focused on the continuous severe drought periods 2014~2015, and understand the model calibrated parameters. The SWAT was applied to a $366.5km^2$ Gongdo watershed by using 14 years (2002~2015) daily observed streamflow (Q) including two years extreme drought period of 2014~2015. The 9 parameters of CN2, CANMX, ESCO, SOL_K, SLSOIL, LAT_TIME, GW_DELAY, GWQMN, ALPHA_BF were selected for model calibration. The SWAT result by focusing on 5 normal years (2002~2006) calibration showed the 14 years average Nash-Sutcliffe model efficiency (NSE) for Q and 1/Q with 0.78 and 0.58 respectively. On the other hand, the 14 years average NSEs of Q and 1/Q by focusing on 2 drought years (2014~2015) calibration were 0.86 and 0.76 respectively. Thus, we could infer that the SWAT calibration trial by focusing on drought periods data can be a good approach to calibrate both high flow and low flow by controlling the 9 drought affected parameters.

Experimental study on vacuum preloading with flocculation for solid-liquid separation in waste slurry

  • Wu, Yajun;Kong, Gangqiang;Lu, Yitian;Sun, De'an
    • Geomechanics and Engineering
    • /
    • v.13 no.2
    • /
    • pp.319-331
    • /
    • 2017
  • This vacuum preloading combined with polyacrylamide (PAM) flocculation was proposed to separating solid-liquid in waste slurry and to improving bearing capacity of soft soil ground. By using waste slurry taken from drilled shaft construction site in Shanghai, China, a series of settling column tests with four typical flocculants and one normal for waste slurry were carried out for comparative analysis. The optimal amounts for each flocculant were obtained from the column tests. Then, model tests on vacuum preloading with anionic polyacrylamide (APAM) flocculation and without flocculants were carried out. The out of water and the settlement of slurry surface ground were monitored during the model tests, and the changes in water content, particle-size and pore-size distributions in different positions after the model tests were measured and discussed. It is found that water content of the waste slurry without APAM flocculation changed from 204 to 195% by 24 hours standing and 15 hours vacuum preloading, while the water content of the waste slurry with APAM flocculation was declined from 163 to 96% by 24 hours standing, and was further reduced into 37% by 136 hours vacuum preloading, which shows that the combined method is feasible and effective.

Comparison of the Rainfall-Runoff Models for Flood Forecasting in Watershed (하천 수계의 홍수 예측을 위한 강우-유출 모형의 비교)

  • 심순보;박노혁
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.237-247
    • /
    • 1996
  • In this study two rainfall-runoff models, the NWS-PC model and the Storage Function Model (SFM), were compared to see their applicability in the flood forecasting at the river system. The SFM has been adopted in the flood-forecasting and warning system for the major rivers in Korea since 1974, and the NWS-PC model, a physically based model, has been developed to simulate soil moisture changing as well as the surface and subsurface flow at the watershed and in the river streams. Case studies were carried out using flood event data observed at the Mihochun watershed in Geum-river basin during 1985 to 1995. Simulated results from both models were compared with the observed data with respect to the RMS errors and relative errors for peak flow discharges and total runoff volumes to show the advantages and disadvantages of both models and to suggest the way to improve their performances.

  • PDF

Assessment of MODIS Leaf Area Index (LAI) Influence on the Penman-Monteith Evapotranspiration Estimation of SLURP Model (MODIS 위성영상으로부터 추출된 엽면적지수(LAI)가 SLURP 모형의 Penman-Monteith 증발산량 추정에 미치는 영향 평가)

  • Ha, Rim;Shin, Hyung-Jin;Hong, Woo-Yong;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1087-1091
    • /
    • 2008
  • Evapotranspiration (ET) is an important factor while simulating daily streamflow in hydrological models. The LAI (Leaf Area Index) value reflecting the conditions of vegetation generally affects considerably in the estimation of ET, for example, when using FAO Penman Monteith equation. Recently in evaluating the vegetation condition as a fixed quantity, the remotely sensed LAIs from MODIS satellite data are avaliable, and the time series values of spatial LAI coupled with land use classes are utilized for ET evaluation. The 4 years (2001-2004) MODIS LAI data were prepared for the evaluation of continuous hydrological model, SLURP (Semi-distributed Land Use-based Runoff Processes). The model was applied for simulating the dam inflow of Chungjudam watershed ($6661.58\;km^2$) located in the upstream of Han river basin of South Korea. From the model results, the FAO Penman Monteith ET was affected by the MODIS LAIs. Especially for the ET of deciduous forest, the Total ET was 33.9 % lager than coniferous forest for the 3.8 % lager of LAI. The watershed average LAI caused a 7.0 % decrease in average soil moisture of the watershed and 14.3 % decrease of ground water recharge.

  • PDF

The prediction of the critical factor of safety of homogeneous finite slopes subjected to earthquake forces using neural networks and multiple regressions

  • Erzin, Yusuf;Cetin, T.
    • Geomechanics and Engineering
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2014
  • In this study, artificial neural network (ANN) and multiple regression (MR) models were developed to predict the critical factor of safety ($F_s$) of the homogeneous finite slopes subjected to earthquake forces. To achieve this, the values of $F_s$ in 5184 nos. of homogeneous finite slopes having different slope, soil and earthquake parameters were calculated by using the Simplified Bishop method and the minimum (critical) $F_s$ for each of the case was determined and used in the development of the ANN and MR models. The results obtained from both the models were compared with those obtained from the calculations. It is found that the ANN model exhibits more reliable predictions than the MR model. Moreover, several performance indices such as the determination coefficient, variance account for, mean absolute error, root mean square error, and the scaled percent error were computed. Also, the receiver operating curves were drawn, and the areas under the curves (AUC) were calculated to assess the prediction capacity of the ANN and MR models developed. The performance level attained in the ANN model shows that the ANN model developed can be used for predicting the critical $F_s$ of the homogeneous finite slopes subjected to earthquake forces.

A Study on the Negative Skin Friction Depending upon the Locations of Piles in a Group Using Model Test (모형시험을 통한 무리말뚝 내 단독말뚝의 위치별 부주면마찰력에 관한 연구)

  • Lim, Jong-Seok;Park, Jong-Hee;Sim, Jong-Sun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1077-1087
    • /
    • 2010
  • Generally most of pile foundations are constructed with group pile rather than single pile. The study on efficiency and bearing capacity which are major elements for rational design of this group pile has been actively progressed, whereas there are truly only a few studies of negative skin friction working on group pile due to the consolidation of ground. The purpose of this study is to determine, among the elements of negative skin friction applied to pile, the occurrence modality of negative skin friction at center, side, and corner of $3{\times}3$ group pile using model test and, based on those observations, to propose the effective design direction of group pile.

  • PDF

A Study on Behavior of Horizontal Pull-out Loaded suction pile in Sands (사질토지반에서 수평인발하중을 받는 석션말뚝에 관한 연구)

  • Kim, Jin-Bok;Park, Joung-Un;Jin, Hong-Min;Kwon, Oh-Kyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1120-1131
    • /
    • 2010
  • In this thesis the model tests were performed to the horizontal pull-out characteristics of a suction pile subjected to a pull in sands. For this model tests, soil conditions ($D_r$=65), three pile diameters (D=100, 150, 200mm) and five loading points (h/L=0, 0.25, 0.5, 0.75, 1) were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate horizontal pull-out resistance by the model test increased as the loading point (h/L) moved downwards from the pile top, and the maximum value reached at the h/L=0.75. The theoretical ultimate horizontal pull-out resistance by Broms(1964) and Hong(1984) agreed well with that by the model test at h/L=0 and 0.25, but their results overestimated the experimental result at lower part of pile and the differences between the theoretical and experimental results were of great. While the horizontal loading applied at the upper part of pile, the pile moved to the horizontal direction with rotating clockwise. As the loading point moved downwards from the pile top, the rotating angle of pile was smaller.

  • PDF

Undrained Behaviour of Normally Consolidated Clay Foundation Using Single-Hardening Constitutive Model (단일황복면 구성모델을 이용한 정규압밀 점토지반의 비배수 거동해석)

  • Jeong, Jin Seob;Lee, Kang Ill;Park, Byung Kee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1229-1241
    • /
    • 1994
  • This study aims at investigating the undrained behavior of the normally consolidated clay foundation using single hardening constitutive model based on elasticity and plasticity theories. The specimen employed was sampled at Mooan near the down stream of Young San river and remolded into consolidation apparatus. 11 soil parameters for the model was determined from simple tests such as isotropic compression and consolidation undrained triaxial compression tests. FEM program to predict the undrained behavior of the foundation was developed and back analysis was performed to verify prediction ability of the FEM program. Finally plate load test on the 2-dimensional model foundation was carried out in order to compare numerical analysis and observed values on the foundation.

  • PDF

Physical and numerical modeling of drag load development on a model end-bearing pile

  • Shen, R.F.;Leung, C.F.;Chow, Y.K.
    • Geomechanics and Engineering
    • /
    • v.5 no.3
    • /
    • pp.195-221
    • /
    • 2013
  • A centrifuge model study is carried out to investigate the behavior of pile subject to negative skin friction induced by pile installation, ground water drawdown and surcharge loading. A single end-bearing pile is examined as the induced negative skin friction would induce the most severe stress on the pile structural material as compared to friction piles. In addition, the behavior of the pile under simultaneous negative skin friction and dead/live loads is examined. To facilitate detailed interpretations of the test results, the model setup is extensively instrumented and involves elaborate test control schemes. To further examine the phenomenon of negative skin friction on an end-bearing pile, finite element analyses were conducted. The numerical analysis is first validated against the centrifuge test data and subsequently extended to examine the effects of pile slenderness ratio, surcharge intensity and pile-soil stiffness ratio on the degree of mobilization of negative skin friction induced on the pile. Finally experimental and numerical studies are conducted to examine the effect of applied transient live load on pile subject to negative skin friction.

Development of engineering software to predict the structural behavior of arch dams

  • Altunisik, Ahmet Can;Kalkan, Ebru;Basaga, Hasan Basri
    • Advances in Computational Design
    • /
    • v.3 no.1
    • /
    • pp.87-112
    • /
    • 2018
  • In this study, it is aimed to present engineering software to estimate the structural response of concrete arch dam. Type-1 concrete arch dam constructed in the laboratory is selected as a reference model. Finite element analyses and experimental measurements are conducted to show the accuracy of initial model. Dynamic analyses are carried out by spectrum analysis under empty reservoir case considering soil-structure interaction and fixed foundation condition. The displacements, principal stresses and strains are presented as an analysis results at all nodal points on downstream and upstream faces of dam body. It is seen from the analyses that there is not any specific ratio between prototype and scaled models for each nodal point with different scale values. So, dynamic analyses results cannot be generalized with a single formula. To eliminate this complexity, the regression analysis, which is a statistical method to obtain the real model results according to the prototype model by using fitting curves, is used. The regression analysis results are validated by numerical solutions using ANSYS software and the error percentages are examined. It is seen that 10% error rates are not exceeded.