• Title/Summary/Keyword: soft start

Search Result 91, Processing Time 0.023 seconds

A CEPHALOMETRIC STUDY ON THE SOFT TISSUE PROFILE CHANGES BY ORTHODONTIC TREATMENT IN FEMALE PATIENTS (여자 부정교합자의 치료전후 연조직 측모 변화에 관한 두부 방사선학적 연구)

  • Park, Sook-Kyu;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.21 no.1 s.33
    • /
    • pp.113-130
    • /
    • 1991
  • This study was undertaken to investigate soft tissue profile changes by orthodontic treatment in female patients. Traditional cephalometric appraisal yields data of dubious scientific value, the soft tissue profile forms were evaluated by finite element method. The subject was divided into three groups according to Angle's classification and each group was composed of 25 female patients averaged aged 12-14 years at the start of treatment. The changes in soft tissue form were evaluated by computing the degree of distortion in each triangle after treatment compared with the triangle before treatment. The conclusions were as follows; 1. The soft tissue profile forms were evaluated by finite element method and independent evaluation of each element by local changes was possible. 2. Maximum and minimum principal strains showed marked variability depending on the particular finite element and each group and Class II, III sample was greater than Class I sample. 3. Soft tissue size changes as a result of orthodontic treatment was not related to those of shape. 4. Soft tissue changes by orthodontic treatment were variable in individual patient, and were not related to Angle's classification.

  • PDF

Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit (전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

Research on the Multi - purpose Nd:YAG Laser Power System using LLC Converter (LLC 공진형 컨버터를 사용한 다용도 Nd:YAG 레이저 전원장치 설계)

  • Zheng, Tao;Kim, Hee-Je;Lee, Jae-cheol;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.885-890
    • /
    • 2015
  • LLC resonant converter has been widely used because of its high efficiency and high energy density. In this paper, we designed a LLC resonant converter as the main power supply of the Nd:YAG pulse laser. First harmonic approximation (FHA) is used to model the LLC resonant converter. FHA equivalent circuit model and the transfer function of the LLC resonant converter is proposed. Soft start technology is also used to suppress the surge current. The laser output simulation test result is identical with the practical test, the laser energy of every pulse can reach up to 2.5J, and the pulse per second (PPS) can be adjusted from 6 to 18. The power system is verified stable and reliable by both of the simulation and experiment results.

Design of monolithic DC-DC Buck converter with on chip soft-start circuit (온칩 시동회로를 갖는 CMOS DC-DC 벅 변환기 설계)

  • Park, Seung-Chan;Lim, Dong-Kyun;Lee, Sang-Min;Yoon, Kwang-Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7A
    • /
    • pp.568-573
    • /
    • 2009
  • This paper presents a step-down DC-DC converter with On-chip Compensation for battery-operated portable electronic devices which are designed in O.13um CMOS standard process. In an effort to decrease system volume, this paper proposes the on chip compensation circuit using capacitor multiplier method. Capacitor multiplier method can minimize error amplifier's compensation capacitor size by 10%. It allows the compensation block of DC-DC converter be easily integrated on a chip and occupy less layout area. But capacitor multiplier operation reduces DC-DC converter efficiency. As a result, this converter shows maximum efficiency over 87.2% for the output voltage of 1.2V (input voltage : 3.3V), maximum load current 500mA, and 25mA output ripple current. This voltage mode controled buck converter has 1MHz switching frequency.

A Digital Self-Sustained Phase Shift Modulation Control Strategy for Full-Bridge LLC Resonant Converters

  • Zheng, Kai;Zhou, Dongfang;Li, Jianbing;Li, Li;Zhao, Yujing
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.915-924
    • /
    • 2016
  • A digital self-sustained phase shift modulation (DSSPSM) strategy that allows for good soft switching and dynamic response performance in the presence of step variations is presented in this paper. The working principle, soft switching characteristics, and voltage gain formulae of a LLC converter with DSSPSM have been provided separately. Furthermore, the method for realizing DSSPSM is proposed. Specifically, some key components of the proposed DSSPSM are carefully investigated, including a parameter variation analysis, the start-up process, and the zero-crossing capture of the resonant current. The simulation and experiment results verify the feasibility of the proposed control method. It is observed that the zero voltage switching of the switches and the zero current switching of the rectifier diodes can be easily realized in presence of step load variations.

Development of an Electronic Starting Controller for Starting Motor of Packaged Power Systems (이동식발전설비의 기동전동기용 전자식 시동 제어장치 개발)

  • Kim, Jong-Su;Yoon, Kyoung-Kuk;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.700-706
    • /
    • 2012
  • The core technology of a starting device in the packaged power system is the pinion gear shifting device and to limit the initial starting voltage. Although the conventional products have been used the starting controller using mechanical contactor, these have a big problem such as the uncertainty for the start of starting motor after a pinion gear is completely shifted or the arc demage due to high current. In this study, in order to solve these problems, we designed and fabricated a new product to achieve the safety and reliability as follows: the pinion gear-shifting control circuits to eliminate the uncertainty of the start, the starting control system using semiconductor device to prevent the arc demage of contactor caused by high current, a start safety devices for soft starting of series motor. In addition, we obtained the electrical safety by separating the pinion gear control circuit and the source circuit of motor.

Effects of a Prefabricated Functional Orthodontic Appliance on Children with Class II Division 1 Malocclusion

  • So-Youn An;Eun-Hee Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.2
    • /
    • pp.112-122
    • /
    • 2023
  • Background: This study aimed to evaluate the effect of a prefabricated functional appliance (Myobrace®) on skeletal, dental, and soft tissue components in children with Class II, division 1 malocclusion. Methods: Thirteen patients with Class II, division 1 malocclusion (9 girls and 4 boys; mean age, 8.2±0.9 years at the start and 9.3±1.0 years at the end of the treatment) were treated with Myobrace® for a mean period of 12.9±4.0 months. Patients were instructed to use the appliance daily for 1 hour and overnight while sleeping. A control group of 10 patients with untreated Class II, division 1 malocclusion (3 girls and 7 boys; mean age, 9.0±1.6 years at the start and 10.4±2.1 years at the end of the observation) was included to eliminate possible growth effects. The mean observation period for this group was 17.7±11.2 months. Lateral cephalograms were taken at the start and end of the treatment, and findings from 41 measurements were analyzed using the V-CephTM program. The mean and standard deviation of cephalometric measurements were analyzed using paired and independent sample t-tests. Results: The treatment group showed significant changes in SNB, ANB, maxillary protrusion, ramus height, proclination of upper anterior teeth, interincisal angle, overjet, and upper lip protrusion compared with the control group. However, only decrease in ANB, maxillary protrusion, overjet, upper lip protrusion, and increase in interincisal angle were significantly higher in the treatment group than in the control group. Conclusion: The prefabricated functional appliance induced skeletal, dentoalveolar, and soft tissue changes, resulting in a significant reduction in anteroposterior discrepancy.

Soft Load Balancing Using the Load Sharing Over Heterogeneous Wireless Networks (이기종 무선 환경에서 Load sharing을 이용한 Soft Load Balancing 기술)

  • Son, Hyuk-Min;Lee, Sang-Hoon;Kim, Soo-Chang;Shin, Yeon-Seung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7A
    • /
    • pp.757-767
    • /
    • 2008
  • Start Ongoing next generation networks are expected to be deployed over current existing networks, in the form of overlayed heterogeneous networks, in particular, in hot spot areas. Therefore, it will be necessary to develop an interworking technique such as load balancing, to achieve increased overall resource utilization in the various heterogeneous networks. In this paper, we present a new load balancing mechanism termed 'soft' load balancing where the IP(Internet Protocol) traffic of a user is divided into sub-traffic, each of which flows into a different access network. The terminology of soft load balancing involves the use of both load sharing and handover techniques. Through a numerical analysis, we obtain an optimal LBR (Load Balancing Ratio) for determining the volume of traffic delivered to each network over an overlayed multi-cell environment. Using the optimal LBR, a more reliable channel transmission can be achieved by reducing the outage probability efficiently for a given user traffic.

A Method for Suppression of Drain Current during Start-up and Short-Circuit Condition of Output Terminals (초기 기동과 출력단 단락시 드레인 전류의 과도한 상승 방지 방법)

  • Koo Gwan-Bon;Kim Jin-Tae;Lee J.Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.43-45
    • /
    • 2006
  • 대부분의 컨버터들은 초기 기동시에 MOSFET 전류와 전압의 과도한 상승을 막아주기 위해서 Soft Start 기능을 갖고 있다. 하지만 제어기 내부의 지연시간이나 LEB(Leading Edge Blanking) 시간 등으로 인해 MOSFET은 무시할 수 없는 상당한 기간의 최소 턴온 시간(Minimum Turn-on Time)을 갖게 되고, 이로 인해 드레인 전류가 과도하게 상승하는 현상을 보이게 된다. 본 논문에서는 이런 현상이 발생할 수 있는 초기 기동이나 출력단 단락시에 과도한 드레인 전류의 상승을 막아주는 방법을 제시하고자 한다.

  • PDF

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.