• Title/Summary/Keyword: smooth curve

Search Result 236, Processing Time 0.03 seconds

Inhibition of voltage-dependent K+ channels by antimuscarinic drug fesoterodine in coronary arterial smooth muscle cells

  • Park, Seojin;Kang, Minji;Heo, Ryeon;Mun, Seo-Yeong;Park, Minju;Han, Eun-Taek;Han, Jin-Hee;Chun, Wanjoo;Park, Hongzoo;Park, Won Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.26 no.5
    • /
    • pp.397-404
    • /
    • 2022
  • Fesoterodine, an antimuscarinic drug, is widely used to treat overactive bladder syndrome. However, there is little information about its effects on vascular K+ channels. In this study, voltage-dependent K+ (Kv) channel inhibition by fesoterodine was investigated using the patch-clamp technique in rabbit coronary artery. In whole-cell patches, the addition of fesoterodine to the bath inhibited the Kv currents in a concentration-dependent manner, with an IC50 value of 3.19 ± 0.91 μM and a Hill coefficient of 0.56 ± 0.03. Although the drug did not alter the voltage-dependence of steady-state activation, it shifted the steady-state inactivation curve to a more negative potential, suggesting that fesoterodine affects the voltage-sensor of the Kv channel. Inhibition by fesoterodine was significantly enhanced by repetitive train pulses (1 or 2 Hz). Furthermore, it significantly increased the recovery time constant from inactivation, suggesting that the Kv channel inhibition by fesoterodine is use (state)-dependent. Its inhibitory effect disappeared by pretreatment with a Kv 1.5 inhibitor. However, pretreatment with Kv2.1 or Kv7 inhibitors did not affect the inhibitory effects on Kv channels. Based on these results, we conclude that fesoterodine inhibits vascular Kv channels (mainly the Kv1.5 subtype) in a concentration- and use (state)-dependent manner, independent of muscarinic receptor antagonism.

Analysis of the First Time User Experience of the online memorial platform and suggestion of service developments (온라인 장례 플랫폼의 초기 사용자 경험 분석및서비스 개발 제안)

  • Jueun Lee;Jindo Hwang
    • Journal of Service Research and Studies
    • /
    • v.14 no.1
    • /
    • pp.44-62
    • /
    • 2024
  • The development of online funeral services and social issues of eco-friendly funeral culture have raised awareness of the new need for online funeral culture. There have been several attempts to revitalize online funeral services in domestic institutions and companies, but the effect is weak. The purpose of this study is to propose a design that can improve the accessibility and usability of online memorial services by analyzing the usability problem factors through a First Time User Experience analysis of the online memorial platform. Therefore, in this study, in order to identify the problem factors of the online memorial platform, a literature review on the UX, OOBE, and FTUE theories was conducted. The subject of the study was the app 'Memorial'. Before analyzing the First-Time User-Experience, IA was compared and analyzed with other similar services to understand the characteristics of the UX service of the app 'Memorial', which is the subject of the study. In addition, tasks corresponding to the Unpack-Setup/Configure-First Use stage were performed on 10 subjects who had no experience using the online memorial platform. The experimental process was expressed as the UX Curve to identify factors that caused negative experiences. As a result, the major problem factors included unnecessary UI elements, the need for sensitive personal information at the membership stage, and lack of immersion in the service. The improvements included strengthening community functions to facilitate the sharing of emotions and promote smooth communication between users. We proposed UI/UX service developments that enhanced the app by incorporating these insights. In order to verify the effectiveness, serviceability, and value of the developed prototype, an interview with a expert was conducted. The interviewes consisted of three service design experts. This study was conducted to contribute to the quality improvement and activation of the recently emerging online funeral services. The study is significant as it aims to understand the current status of these services and identify the factors necessary to improve service accessibility and usability. Subsequent studies require in-depth user verification of how much the proposed improvement plan affects the actual user experience.

Spatial and Temporal Analyses of Cervical Cancer Patients in Upper Northern Thailand

  • Thongsak, Natthapat;Chitapanarux, Imjai;Suprasert, Prapaporn;Prasitwattanaseree, Sukon;Bunyatisai, Walaithip;Sripan, Patumrat;Traisathit, Patrinee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.5011-5017
    • /
    • 2016
  • Background: Cervical cancer is a major public health problem worldwide. There have been several studies indicating that risk is associated with geographic location and that the incidence of cervical cancer has changed over time. In Thailand, incidence rates have also been found to be different in each region. Methods: Participants were women living or having lived in upper Northern Thailand and subjected to cervical screening at Maharaj Nakorn Chiang Mai Hospital between January 2010 and December 2014. Generalized additive models with Loess smooth curve fitting were applied to estimate the risk of cervical cancer. For the spatial analysis, Google Maps were employed to find the geographical locations of the participants' addresses. The Quantum Geographic Information System was used to make a map of cervical cancer risk. Two univariate smooths: x equal to the residency duration was used in the temporal analysis of residency duration, and x equal to the calendar year that participants moved to upper Northern Thailand or birth year for participants already living there, were used in the temporal analysis of the earliest year. The spatial-temporal analysis was conducted in the same way as the spatial analysis except that the data were split into overlapping calendar years. Results: In the spatial analysis, the risk of cervical cancer was shown to be highest in the Eastern sector of upper Northern Thailand (p-value <0.001). In the temporal analysis of residency duration, the risk was shown to be steadily increasing (p-value =0.008), and in the temporal analysis of the earliest year, the risk was observed to be steadily decreasing (p-value=0.016). In the spatial-temporal analysis, the risk was stably higher in Chiang Rai and Nan provinces compared to Chiang Mai province. According to the display movement over time, the odds of developing cervical cancer declined in all provinces. Conclusions: The risk of cervical cancer has decreased over time but, in some areas, there is a higher risk than in the major province of Chiang Mai. Therefore, we should promote cervical cancer screening coverage in all areas, especially where access is difficult and/or to women of lower socioeconomic status.

Effects of $Ca^{++}$, Verapamil and $La^{+++}$ on the Spontaneous Contraction and K-contracture in the Isolated Rat Uterine Smooth Muscle (칼슘, 베라파밀, 란타눔이 흰쥐 자궁근의 자발적 수축과 칼륨 경축에 미치는 효과)

  • Hwang, Sang-Ik
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.37-50
    • /
    • 1984
  • The effects of $Ca^{++}$ and its antagonists (verapamil and $La^{+++}$) upon the spontaneous contraction and the contracture induced by 60 mM K-Tyrode solution were studied in the isolated uterine muscle. Longitudinal muscle strips were prepared from the rat uteri at estrous stage. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2$ and kept at 35^{\circ}$. The results obtained were as follows: 1) In the uterine strips contracting spontaneously, both the amplitude of peak tension and the area of contraction curve increased dose-dependently in the range of $0.5${\sim}8$ mM $Ca^{++}$. The frequency of contraction increased as the concentration of $Ca^{++}$ increased up to 2 mM, but above this concentration the frequency decreased. In $Ca^{++}-free$ media, however, contraction did not develop. In the contracture induced by 60 mM K-Tyrode solution, the developed tension increased dose-dependently as the concentration of external $Ca^{++}$ increased to 8 mM. In the absence of external $Ca^{++}$ K-contracture appeared, but it was not sustained. 2) The spontaneous contraction of rat uterus was suppressed by verapamil in proportion to an increase of its concentration and totally abolished at the concentration of $3{\times}10^{-4}\;g/l$, but the spontaneous contraction re-appeared by addition of $Ca^{++}$. The amplitude of peak tension recovered completely but the recovery of frequency was incomplete. K-contracture decreased in a dose-dependent manner after the treatment with verapamil and totally disappeared at its concentration of $3{\times}10^{-4}\;g/l$. Even in this case contracture developed again by extra $Ca^{++}$. 3) The spontaneous contractile activity was inhibited by $La^{+++}$. At the concentration of $10^{-4}$M $La^{+++}$, fibrillation appeared. In the strip inhibited by $10^{-5}M\;La^{+++}$, contractility recovered completely by extra $Ca^{++}$ while in the $10^{-4}M\;La^{+++}$ treated preparation, the rhythmic spontaneous contraction did not develop even at the concentration of 16 mM $Ca^{++}$. After the initial transient depression of contracture tension by $10^{-3}M$ of $La^{+++}$, the strip stowed considerably large size of contracture, hardly influenced by external $Ca^{++}$ or verapamil. The results obtained in this experiment suggest that in the rat uterine muscle there would be some competitive actions between $Ca^{++}$ and its antagonists. It is speculated that $Ca^{++}$ plays an important role in the conduction of excitation, and $La^{+++}$ influences upon cellular $Ca^{++}$ mobilization and re-uptake process as well as transmembrane $Ca^{++}$ transport in a K-depolarized state.

  • PDF

Induces Vasodilatation of Rat Mesenteric Artery in vitro Mainly by Inhibiting Receptor-Mediated $Ca^{2+}$ -Influx and $Ca^{2+}$ -Release

  • Cao Yong-Xiao;Zheng Jian-Pu;He Jian-Yu;Li Jie;Xu Cang-Bao;Edvinsson Lars
    • Archives of Pharmacal Research
    • /
    • v.28 no.6
    • /
    • pp.709-715
    • /
    • 2005
  • The purpose of this study was to investigate the effect of atropine on peripheral vasodilation and the mechanisms involved. The isometric tension of rat mesenteric artery rings was recorded in vitro on a myograph. The results showed that atropine, at concentrations greater than 1$\mu$M, relaxed the noradrenalin (NA)-precontracted rat mesenteric artery in a concentration-dependent manner. Atropine-induced vasodilatation was mediated, in part, by an endothelium-dependent mechanism, to which endothelium-derived hyperpolarizing factor may contribute. Atropine was able to shift the NA-induced concentration-response curve to the right, in a non-parallel manner, suggesting the mechanism of atropine was not mediated via the ${\alpha}_1$-adrenoreceptor. The $\beta$-adrenoreceptor and ATP sensitive potassium channel, a voltage dependent calcium channel, were not involved in the vasodilatation. However, atropine inhibited the contraction derived from NA and $CaCl_2$ in $Ca^{2+}$-free medium, in a concentration dependent manner, indicating the vasodilatation was related to the inhibition of extracellular $Ca^{2+}$ influx through the receptor-operated calcium channels and intracellular $Ca^{2+}$ release from the $Ca^{2+}$ store. Atropine had no effect on the caffeine-induced contraction in the artery segments, indicating the inhibition of intracellular $Ca^{2+}$ release as a result of atropine most likely occurs via the IP3 pathway rather than the ryanodine receptors. Our results suggest that atropine-induced vasodilatation is mainly from artery smooth muscle cells due to inhibition of the receptor-mediated $Ca^{2+}$-influx and $Ca^{2+}$-release, and partly from the endothelium mediated by EDHF.

On the Reclamation Earthwork Calculation using the Hermite and Spline Function (Hermite와 Spline 함수를 이용한 매립토공량 계산)

  • Mun, Du-Yeoul;Lee, Yong-Hee;Lee, Mun-Jae
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.473-479
    • /
    • 2002
  • The estimation of the volume of a pit excavation is often required in many surveying, soil mechanics, highway applications and transportation engineering situations. The calculation of earthwork plays a major role in plan or design of many civil engineering projects such as seashore reclamation, and thus it has become very important to improve the accuracy of earthwork calculation. In this paper the spot height method, proposed formulas(A, B, C), and chen and Line method are compared with the volumes of the pits in these examples. And we proposed an algorithm of finding a terrain surface with the free boundary conditions and both direction spline method drawback, i.e., the modeling curves form peak points at the joints. To avoid this drawback, the cubic spline polynomial was chosen as the methematical model of the new method. From the characteristics of the cubic spline polynomial, the modeling curve of the new method was smooth and matched the ground profile well. As a result of this study, algorithm of proposed three methods to estimate pit excavation volume provided a better accuracy than spot height, chamber, chen and Lin method. And the mathematical model mentioned makes is thought to give a maximum acccuracy in estimating the volume of a pit excavation.

Electrical Characteristic of IGZO Oxide TFTs with 3 Layer Gate Insulator

  • Lim, Sang Chul;Koo, Jae Bon;Park, Chan Woo;Jung, Soon-Won;Na, Bock Soon;Lee, Sang Seok;Cho, Kyoung Ik;Chu, Hye Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.344-344
    • /
    • 2014
  • Transparent amorphous oxide semiconductors such as a In-Ga-Zn-O (a-IGZO) have advantages for large area electronic devices; e.g., uniform deposition at a large area, optical transparency, a smooth surface, and large electron mobility >10 cm2/Vs, which is more than an order of magnitude larger than that of hydrogen amorphous silicon (a-Si;H).1) Thin film transistors (TFTs) that employ amorphous oxide semiconductors such as ZnO, In-Ga-Zn-O, or Hf-In-Zn-O (HIZO) are currently subject of intensive study owing to their high potential for application in flat panel displays. The device fabrication process involves a series of thin film deposition and photolithographic patterning steps. In order to minimize contamination, the substrates usually undergo a cleaning procedure using deionized water, before and after the growth of thin films by sputtering methods. The devices structure were fabricated top-contact gate TFTs using the a-IGZO films on the plastic substrates. The channel width and length were 80 and 20 um, respectively. The source and drain electrode regions were defined by photolithography and wet etching process. The electrodes consisting of Ti(15 nm)/Al(120 nm)/Ti(15nm) trilayers were deposited by direct current sputtering. The 30 nm thickness active IGZO layer deposited by rf magnetron sputtering at room temperature. The deposition condition is as follows: a rf power 200 W, a pressure of 5 mtorr, 10% of oxygen [O2/(O2+Ar)=0.1], and room temperature. A 9-nm-thick Al2O3 layer was formed as a first, third gate insulator by ALD deposition. A 290-nm-thick SS6908 organic dielectrics formed as second gate insulator by spin-coating. The schematic structure of the IGZO TFT is top gate contact geometry device structure for typical TFTs fabricated in this study. Drain current (IDS) versus drain-source voltage (VDS) output characteristics curve of a IGZO TFTs fabricated using the 3-layer gate insulator on a plastic substrate and log(IDS)-gate voltage (VG) characteristics for typical IGZO TFTs. The TFTs device has a channel width (W) of $80{\mu}m$ and a channel length (L) of $20{\mu}m$. The IDS-VDS curves showed well-defined transistor characteristics with saturation effects at VG>-10 V and VDS>-20 V for the inkjet printing IGZO device. The carrier charge mobility was determined to be 15.18 cm^2 V-1s-1 with FET threshold voltage of -3 V and on/off current ratio 10^9.

  • PDF

Effects of Arachidonic Acid on the Calcium Channel Current $(I_{Ba})$ and on the Osmotic Stretch-induced Increase of $I_{Ba}$ in Guinea-Pig Gastric Myocytes

  • Xu, Wen-Xie;Kim, Sung-Joon;So, In-Suk;Suh, Suk-Hyo;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.4
    • /
    • pp.435-443
    • /
    • 1997
  • We employed the whole-cell patch clamp technique to investigate the effects of arachidonic acid (AA) on barium inward current through the L-type calcium channels ($I_{Ba}$) and on osmotic stretch-induced increase of $I_{Ba}$ in guinea-pig antral gastric myocytes. Under isosmotic condition, AA inhibited $I_{Ba}$ in a dose-dependent manner to $91.1{\pm}1.4,\;72.0{\pm}3.2,\;46.0{\pm}1.8,\;and\;20.3{\pm}2.3%$ at 1, 5, 10, 30 mM, respectively. The inhibitory effect of AA was not affected by 10 ${\mu}M$ indomethacin, a cyclooxygenase inhibitor. Other unsaturated fatty acids, linoleic acid (LA) and oleic acid (OA) were also found to suppress $I_{Ba}$ but stearic acid (SA), a saturated fatty acid, had no inhibitory effect on $I_{Ba}$. The potency sequence of these inhibitory effects was AA ($79.7{\pm}2.3%$) > LA ($43.1{\pm}2.7%$) > OA ($14.2{\pm}1.1%$) at 30 ${\mu}M$. On superfusing the myocyte with hyposmotic solution (214 mOsm) the amplitude of $I_{Ba}$ at 0 mV increased ($38.0{\pm}5.5%$); this increase was completely blocked by pretreatment with 30 mM AA, but not significantly inhibited by lower concentrations of AA (1, 5 and 10 ${\mu}M$) (P>0.05). Unsaturated fatty acids shifted the steady-state inactivation curves of $I_{Ba}$ to the left; the extent of shift caused by AA was greater than that caused by LA. The activation curve was not affected by AA or LA. The results suggest that AA and other unsaturated fatty acids directly modulate L-type calcium channels and AA might modulate the hyposmotic stretch- induced increase of L-type calcium channel current in guinea-pig gastric smooth muscle.

  • PDF

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load (편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향)

  • Lee, Young Ho;Chung, Heon Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.95-104
    • /
    • 2007
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns subjected to eccentric compressive loads. The twenty-four concrete columns with $200mm{\times}200mm$ square cross-section were tested. The main variables were concrete strength, spacing and configuration of lateral ties, and eccentricity ratios. From the experiment, the followings were investigated ; 1) In all cases, it was observed that the increase of concrete compressive strength led to the decrease of ductility. Also, as the eccentricity ratios increased, the effect of ductility enhancement by lateral ties decreased. 2) As the ties spacing decreased from 100mm to 30mm, the magnitude of axial load acting on the concrete column showed an enhancement of 1.1~1.2 times and the descending curve after a peak moment presented a smooth decline. 3) The high-strength concrete columns required a design of lateral ties to increase the volumetric ratios and density of tie spacing to sustain a proper strength and ductility. Accordingly, regardless of concrete strength, the current AIK design code to specify the maximum tie spacing of concrete columns was proven to lead to the poor strength and ductility for seismic design. Therefore, it is necessary to develop a new seismic design code that connects volumetric ratios and tie spacing of concrete columns with concrete strength.

- The Review of the Collar Consideration of G go-ri to Improve Drafting Method - (제도법 개선을 위한 저고리 깃 구성의 재고찰)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.4
    • /
    • pp.249-263
    • /
    • 1996
  • According to the design method for constructing the G gori(the traditional Korean jacket)collar, there are differences in form after its completion. In the construction design of the midsection of the gusset as in that of the basic G gori, not only was the positioning of the two sides of the collar not smooth, but also, when the collar strip was attached, there would be an imbalance on one side or the other so that it was difficult to achieve symetry. Therefore in this project, by applying the pattern design of the gusset midsection to that of the collar midsection, not only did attaching the collar and the collar strip create a visual effect by equalizing the lengths of the tow sides, but the construction was also easy. This method of construction introduces the three-dimensional aspect of the human form in its conic, spherical and cylindrical aspects, so that, through schematizing the scientific character of Korea's clothing, its appropriateness is verified. As a matter of fact, since th-ere in no standardization of pattern whether for educational use or for mass-produced clothing, so that even the patterns used in computer-assisted design are executed according to the designer's personal skill, the reality is that after completion of construction the quality has not been uniform. For this schematization, inverse calculation of measurements pertaining to the calculation formula and of teaching materials has been referenced. In particular, the partial requlation of the calculation formula pertaining to the basic pattern construction, the method of making the collar midsection, and the construction method of the extreme and mean ratio adjustment can be adjusted for all measurements, thereby providing the establishment of a design criterion and the possibility of the standardization of construction methods. The production method for the pattern design is as follows: 1) The conic angle for the G gori's girth, length and neck width is fixed at 70 degrees. 2) The radius of the cone is B/2. 3) The calculation formula is B/4 + 1.5cm 4) The armhole formula is B/4, the same as in the basic method. 5) The width formula is B/10. 6) The ratio of the collar junction(width of collar + width of collar strip)to the gusset length is 5:8. 7) The length of the side seam is a length intersecting the armhole line and the conic radius (B/2), that is an arc that exceeds the length of the G gori's midsection; the component ratio of this length to the collar junction is accordingly 13:5. 8) The curve frame length of the back midsection is an arc exceeding B/4(the armhole line). 9) The ratio of the sleeve opening calculation formula to the armhole length is 8:5, forming an arc with the midsection length.

  • PDF