• Title/Summary/Keyword: smooth

Search Result 6,576, Processing Time 0.034 seconds

Design and Implementation of ASTERIX Parsing Module Based on Pattern Matching for Air Traffic Control Display System (항공관제용 현시시스템을 위한 패턴매칭 기반의 ASTERIX 파싱 모듈 설계 및 구현)

  • Kim, Kanghee;Kim, Hojoong;Yin, Run Dong;Choi, SangBang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.89-101
    • /
    • 2014
  • Recently, as domestic air traffic dramatically increases, the need of ATC(air traffic control) systems has grown for safe and efficient ATM(air traffic management). Especially, for smooth ATC, it is far more important that performance of display system which should show all air traffic situation in FIR(Flight Information Region) without additional latency is guaranteed. In this paper, we design a ASTERIX(All purpose STructured Eurocontrol suRveillance Information eXchange) parsing module to promote stable ATC by minimizing system loads, which is connected with reducing overheads arisen when we parse ASTERIX message. Our ASTERIX parsing module based on pattern matching creates patterns by analyzing received ASTERIX data, and handles following received ASTERIX data using pre-defined procedure through patterns. This module minimizes display errors by rapidly extracting only necessary information for display different from existing parsing module containing unnecessary parsing procedure. Therefore, this designed module is to enable controllers to operate stable ATC. The comparison with existing general bit level ASTERIX parsing module shows that ASTERIX parsing module based on pattern matching has shorter processing delay, higher throughput, and lower CPU usage.

Optimal Payment Contracts in Agent-Owner Relationship (대리인-선주간의 최적보상계약에 관한 연구)

  • 육근효
    • The Journal of Fisheries Business Administration
    • /
    • v.18 no.1
    • /
    • pp.37-57
    • /
    • 1987
  • This article discussed the characteristics of several Pareto-optimal incentive contracts between owner and labor, more specifically, four situations: reporting output jointly observable by labor ana owner; reporting both output and effort; incorporating other endogenous elements (like capital) that affect the production process and Pareto-optimal fee schedules; and ascertaining the effects of private pre-decision information private- decision information, and per-contact informational asymmetries. Also presented were several extensions of the basic contractual model, and the different components of agency costs associated with labor-owner contractual relations. In a single-period model, the agency problem exists because the uncertainty prevents the owner from using the cash flow to determine unambiguously the labor's action. Holmstrom(1979) suggests that "when the same situation repeats itself over time, the effects of uncertainty tend to be reduced and dystunctional behavior is more accurately revealed, thus alleviating the problem of moral hazard. " Under these conditions, if the labor selects the first-best level of effect in each period, the cash flow will be independent and identically distributed over time. As the number of periods increases, the variance of the labows average output, if he selects the first-best level of effort in each period, gets smaller. Note that for this diversification effect to occur, it is necessary that the owner evaluate the labor's effort over the entire history of his employment, rather than evaluate each period's performance separately. Radner(1980) and Rubinstein and Yaari(1980) consider the extreme case in which there are an infinite number of observations. They show that the owner can eventually detect and systematic shirking on the part of the labor by comparing the labor's average output with what would be expected if the labor had been selecting the first-best level of effort in each period. In a dynamic model with incentive problems we have demonstrated that the labor's second-period compensation will depend on his first-period performance. This allows the owner to diversify away some of the uncertainty surrounding the labor's actions. In addition, this allows the owner to smooth the labor's income over time by spreading the risk of the first-period outcome over both periods. At least some unexplored avenves in this area invite future accounting research: situations where owner has different incompatible objectives and negotiates a contract with labor; circumstances in which owner deals with multiple objectives and negotiates contracts with several labors simultaneously; the value of costly accounting information systems and communication in establishing, Pareto-optimal incentive contracts, and the value and effects of inside information, Thorough theoretical or empirical research on each of these topics not only would increase our knowledge about the role and significance of accounting information but could also provide explanations of the inherent differences among various organizations and in their economic behavior. behavior.

  • PDF

EEFFECTS OF TOPICAL AND INTRAVENOUS HEPARIN ON THROMBOSIS OF MICROVASCULAR ANASTOMOSES (미세혈관문합시 헤파린의 국소 및 전신 투여가 혈전 형성에 미치는 영향)

  • Kim, Sung-Youl;Ryu, Seong-Hee;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kim, Ok-Joon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.232-238
    • /
    • 2003
  • This study was performed to evaluate the effect of topical and intravenous heparin on thrombosis and patency in the microvascular anastomosis of the traumatized veins. Nine white rabbits weighing about 2 kg were used. After exposure of both femoral veins, the veins were crushed by the jaws of smooth needle holder in order to create a thrombosis model. Transectional incision was made in the vein. The animals were then divided into 3 groups based on the administration method of heparin: 1) Experimental Group I, topical irrigation of lumen with heparin saline solution (n=6); 2) Experimental Group 2, topical irrigation of lumen with heparin saline solution and intravenous injection of heparin (0.75 mg/kg) via the marginal ear vein for 3 days; 3) Control Group, topical irrigation of lumen with saline solution (n=6). The patency was evaluated with empty-and-refill test and thrombus formation was judged by surgical microscope. The results were as follows: 1. Thirty minutes after microvascular anastomosis, the patency of all Experimental Groups was better than Control group. However, there was no significant difference among groups. 2. Three days after anastomosis, the patency of all Experimental Groups was much more improved than that of Control Group (P<0.05). There was no significant difference between Experimental Group 1 and 2. 3. Three days after anastomosis, the amount of thrombus in all Experimental Groups was much less than that of Control Group (P<0.05). 4. In histologic findings a lot of luminal thrombus were observed around sutured area in Control Groups. Few luminal thrombus was observed in all Experimental Groups. Mild necrosis in the vessel wall was observed around sutured area in all specimens. These results indicate that topical irrigation of heparin may improve the patency and inhibit the formation thrombus in the microvascular anastomosis of the traumatized veins.

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT (임플랜트 표면처리가 생체활성에 미치는 영향)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Yoon, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

A STUDY ON SURFACE ROUGHNESS OF METALS ACCORDING TO FINISHING AND POLISHING PROCEDURES - AN ATOMIC FORCE MICROSCOPE ANALYSIS - (연마방법에 따른 금속의 활택도에 관한 연구 - Atomic Force Microscope를 이용한 -)

  • Park Won-Kyu;Woo Yi-Hyung;Choi Boo-Byung;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.1-19
    • /
    • 2003
  • The surface of metals should be as smooth as possible for optimum comfort, oral hygiene, low plaque retention, and resistance to corrosion. In this study five specimens of each precious metal(type III gold alloy, ceramic gold alloy, and Ag-Pd alloy) were divided into five groups according to finishing and polishing procedures : group 1(sandblaster), group 2(group 1+stone), group 3(group 2+brown rubber), group 4(group 3+green rubber), and group 5(group 4+rouge). Six specimens of each non-precious metal(Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy) were divided into six groups: group 1(sandblaster), group 2(group 1+hard stone), group 3(group 2+electrolytic polisher), group 4(group 3+brown hard rubber point), group 5(group 4+green hard rubber point), and group 6(group 5+rouge). Considering factors affecting the rate of abrasion, the same dentist applied each finishing and polishing procedure. In addition, the surface roughness of enamel, resin, and porcelain was evaluated. The effect of finishing and polishing procedures on surface roughness of precious and non-precious metals, enamel, resin, and porcelain was evaluated by means of Atomic Force Microscope(AutoProbe CP. Park Scientific Instruments, U.S.A.) that can image the three dimensional surface profile and measure average surface roughness values of each sample at the same time. The obtained results were as follows : 1. According to finishing and polishing procedures, the surface roughness of type III gold alloy, ceramic gold alloy, and Ag-Pd alloy was decreased in the order of group 1, 2, 3, 4, and 5 (P<0.01). 2. According to finishing and polishing procedures. the surface roughness of Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy was decreased in the order of group 1, 2, 3, 4, 5, and 6 (p<0.01). 3. There was not statistically significant difference in the surface roughness among three metals of precious metals in group 1 but was significant difference in group 2, 3, 4, and 5 (P<0.05). 4. There was not statistically significant difference in the surface roughness among three metals of non-precious metals in all groups. 5. When the surface roughness of the smoothest surface of each metal, enamel. porcelain, and resin was compared, porcelain was the smoothest and the surface roughness was decreased in the order of Ni-Cr alloy. Co-Cr alloy. Co-Cr-Ti alloy, resin. Ag-Pd alloy, ceramic gold alloy type III gold alloy, and enamel (P<0.01). The results of this study indicate that the finishing and polishing procedures should be carried out in a logical, systematic sequence of steps and the harder non-precious metals may be less resistance to abrasion than are the softer precious metals.

CELLULAR RESPONSES ON ANODIZED TITANIUM DISCS COATED WITH $1{\alpha}$,25-DIHYDROXYVITAMIN D3 INCORPORATED POLY (D,L-LACTIDE-CO-GLYCOLIDE) (PLGA) NANOPARTICLES

  • Cho, Young-Jin;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.620-627
    • /
    • 2008
  • STATEMENT OF PROBLEM: A biochemical approach for surface modification has offered an alternative for physicochemical and morphological methods to obtain desirable bone-implant interfaces. PURPOSE: The purpose of the present study was to investigate cell responses to poly (D,L-lactide-co-glycolide) (PLGA)/$1{\alpha}$,25-(OH)$_2D_3$ coating with reference to cellular proliferation and differentiation in vitro. MATERIAL AND METHODS: 96 titanium discs were fabricated and divided into four groups. Group 1 was anodized under 300 V as control. Group 2, 3 and 4 were anodized then coated with 3 ml PLGA/$1{\alpha}$,25-(OH)$_2D_3$ solutions. Amount of the solutions were 2 ul, 20 ul and 200ul respectively. The osteoblast-like Human Osteogenic Sarcoma (HOS) cells were seeded and cultured for 1, 3 and 7 days. MTSbased cell proliferation assay and ALPase activity test were carried out. RESULTS: PLGA nanoparticles were observed as fine, smooth and round and HOS cells attached to the anodized surfaces through strand-like and sheet-like filopodia. After 3 days of culture, the dendritic filopodia were exaggerated and sheet-like cytoplasmic projections covered the coated titanium surfaces. After 3 days of culture, all of the groups showed increased cellular proliferation and the lowest proliferation rate was measured on group 2. Higher amount of incorporated $1{\alpha}$,25-(OH)$_2D_3$ (Group 3 and 4) improved cellular proliferation but the differences were not significant statistically (P > .05). But they increased the rate of ALP activities than the control group at day 3 (P < .05). CONCLUSION: Biodegradable PLGA nanoparticles incorporated with vitamin D metabolite positively affected proliferation and differentiation of cells on the anodized titanium surface.

Microleakage Assessment of Resin Infiltration Combined Restoration in Artificial Decalcified-Cavitated Lesion (인공 우식 수복시 레진 침투법 전처리의 미세누출에 대한 효과)

  • Jang, Eunjeong;Park, Soyoung;Shin, Jonghyun;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.257-265
    • /
    • 2020
  • This study was performed to evaluate the restoration combined with resin infiltration (RI) of early cavitated smooth surface caries lesion in terms of microleakage. Flowable resin and resin-modified glass ionomer cement (RMGIC) were compared. Sound 20 extracted 3rd molars were divided into 2 groups randomly. Artificial decalcified lesion was induced. Cavities were prepared on the mesial and distal surfaces, and randomly set as experimental and control group. RI was applied to the experimental group before cavity restoration. The control group was restored without RI. In group I and II, flowable resin and RMGIC was used for restoration respectively. After thermocycling and silver nitrate immersion, microleakage was assessed by μ-CT. Depth of microleakage was lower in experimental group than control group only in group II (p = 0.05). Microleakage depth was lower in group II than group I in both experimental and control groups (p = 0.05). RI pretreatment before restoration of early cavitated caries lesions might reduce the microleakage and help long-term maintenance of restoration. In this study, RMGIC was less polymerization shrinkage. Restoration with RMGIC after RI pretreatment reduced the microleakage of the restoration compared to the flowable resin.

Effects of Leveler on the Trench Filling during Damascene Copper Plating (전해전착시 상감 구리 배선의 충전에 미치는 레벨러의 효과)

  • Lee, Yu-Young;Park, Young-Joon;Lee, Jae-Bong;Cho, Byung-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.3
    • /
    • pp.153-158
    • /
    • 2002
  • The effects of leveler on the copper trench filling were investigated during damascene plating process. To investigate the trench filling effect with the addition of a leveler, a cross-section images of the electroplated trenches with the width of$0.37{\mu}m,\;and\;0.18{\mu}m$ were observed by field emission scanning electron microscope (FE-SEM). Polyethylene glycol(PEG), 3-mercapto-1-propanesulfonic acid and Janus Green B were used as a carrier, an accelerator and a leveler. $0.37{\mu}m$ trenches were superfilled without voids, but there was voids formation in $0.18{\mu}m$ trenches when the leveler was not added into the electrolyte. On the other hand $0.18{\mu}m$ trenches were superfilled without voids with the addition of the leveler due to the reduction growth rate of copper at protrusions and edges, which yield smooth final deposit surface. The leverer effect becomes more significant as the width of trenches becomes smaller when trenches are filed.

Comparative Study of the Clinicopathologic Characteristics between Gastrointestinal Stromal Tumors Arising from the Stomach and Small Bowel (위와 소장에 생긴 위장관 간질종양의 임상병리학적 비교)

  • Heo, Geon-Woong;Shin, Dong-Woo;Paik, So-Ya;Kim, Il-Dong;Kim, Ki-Ho;Suh, Byung-Sun;Park, Jin-Soo;Kim, Sang-Wook
    • Journal of Gastric Cancer
    • /
    • v.7 no.4
    • /
    • pp.254-260
    • /
    • 2007
  • Purpose: The purpose of this study is to compare the clinicopathological characteristics of stomach and small bowel gastrointestinal stromal tumors and to determine the risk factors and treatment guidelines. Materials and Methods: Among 38 patients who were diagnosed with a gastrointestinal stromal tumor from August 1998 to May 2006, 29 patients at the Pundang Jesaeng General Hospital, Daejin Medical Center were evaluated. The clinicopathological characteristics of gastrointestinal stromal tumors arising from stomach and small bowel were compared. Immunohistochemical staining for CD117, CD34, smooth muscle actin, desmin, and S-100 protein was performed and classified according to NIH criteria. Prognosis between groups was analyzed according to NIH criteria. Results: There was no significant difference in the clinicopathological characteristics and prognosis between gastrointestinal stromal tumors arising from the stomach and small bowel. Recurrence of the disease occurred in four (13.8%) patients. Classification of gastrointestinal stromal tumors according to NIH criteria was predictive of recurrence (P=0.030). Conclusion: NIH criteria were predictive of recurrence, but the location of the primary site was not predictive of recurrence. A further study involving multi center data and a long-term follow-up will be needed for formulating diagnostic and therapeutic guidelines.

  • PDF