• Title/Summary/Keyword: smoke detector

Search Result 106, Processing Time 0.024 seconds

Smoke Density and Operation of Fire Detector Influenced by Air Stream (기류순환이 연기농도와 감지기 작동에 미치는 영향)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.28-32
    • /
    • 2002
  • The performance based design in fire detection system, the effect of high airflow and dilution of smoke produced in any fire situation serve to increase the response time of point-type smoke detectors. This study investigated the smoke density of ceiling, under the air stream and in normal status when fire type is smoldering fires. The result of study, smoke generated in the fire was swept away from nearby spot type smoke detector which failed to actuate because dispersed in diluted form around the room. The concept of performance based design in fire detection system of protected area influenced by high airflow provided the need of active fire detection system such as air sampling smoke detection system.

Optical Properties for Smoke Particles of Fire Sources According to UL 268 (UL 268 화원에 의한 연기입자의 광학적 특성)

  • Jee, Seung-Wook;Lee, Jong-Hwa
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.9-13
    • /
    • 2014
  • This paper is basic study for development of the photoelectric-type smoke detector that is able to distinguish fire source as well as fire detection. For this subject, Light source and sensor which is normally used for the conventional smoke detector are assembled for the optical chamber. Using 3 type of the test fires (the paper fire, the wood fire, the flammable liquid fire) this paper attempts to find optical properties of each fire. These 3 type of fire are used in the testing of smoke detector according to UL 268 standard. As the result, there are disambiguated between the paper fire and the wood fire in scattering and reason of extinction in the flammable liquid fire is different from that of the paper and the wood fire.

A Study on the Problem and Improvement of Fire Detector Test in the Field Inspection (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Cha, Ha-Na;Ok, Kyung-Jae;Kim, Shi-Kuk;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.50-53
    • /
    • 2008
  • This study has been conducted for the purpose of considering the problems expected when checking the smoke detector at site and how to improve the smoke detector. We have conducted this study focused on checking the problems expected upon site inspection and finding out the way of improving the site inspection by analyzing the reliability and performance of instrument used upon site inspection. The test results show that some problems exist in the reliability and performance of instrument used for the site inspection of smoke detector way of inspecting the inspection instrument.

A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House (주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.67-72
    • /
    • 2009
  • This paper is for response feature of fire detectors not only to analysis response feature of fire detector, but also to observe flame spread of inside-building and fire enlargement by using the row house which is supposed to be broken up. Many kinds of popular detectors such as heat type detector(differential type, fixed temperature type, Analogue type)and smoke type(light scattered type, Analogue type, single alarm type) were installed in the house in order to check for the change of temperature by installing of thermocouples. As a result, smoke detectors are better than heat detectors when it comes to making effective fire-detect system in the row house.

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

Test Method Using Shield-cup for Evaluating Response Characteristics of Fire Detectors (화재감지기의 응답특성 평가를 위한 Shield-cup이 적용된 시험방법)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.36-44
    • /
    • 2020
  • It is necessary to predict the activation time of fire detectors accurately to improve the reliability for evaluating the required safe egress time (RSET) in performance-based fire safety design. In this study, problems of the plunge test, which is widely applied in assessing fire detectors, were examined through experiments and numerical simulations. In addition, a new shield-cup test method was proposed to address these problems. A fire detector evaluator (FDE) developed in a previous study was applied to ensure measurement accuracy and reproducibility. During the plunge tests, a significant measurement error was observed in the activation time of the smoke detector because of the rapid flow change when the detector was input. However, during the shield-cup tests, slight changes occurred in the flow inside the FDE when the detector as exposed to smoke. In conclusion, the proposed shield-cup test method is expected to be useful for evaluating the response characteristics of fire detectors more accurately in simulated fire environments.

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

An Experimental Study of Flow Behaviour in Underground Stairway Fire (지하계단 화재에서 유동에 대한 실험연구)

  • 정진용;홍기배;이재하;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.821-827
    • /
    • 2003
  • Reduced-scale experimental study was carried out on the heat flow behavior which flows under the sloped ceiling in underground fire. Temperature and flow velocity were measured to characterize the ceiling jet along the sloped stairway ceiling. The methanol fuel was used as a model fire source giving 2.2 and 3.4 kW, with changing the slope angle of stairway adopting of 15, 25, 35, and 45 deg. Based on the experimental data, excess temperature and velocity along the sloped stairway ceiling were examined which are usefully applicable to estimate the activating conditions of heat detector and sprinkler head mounted on the sloped ceiling. Excess temperature in upper exit of the sloped stairway was also examined to analyze the soffit which delays the smoke diffusion. The result shows that the activating conditions of heat detector and sprinkler in the sloped stairway ceiling have to be considered differently in a point of about 30 deg.