• Title/Summary/Keyword: small water system

Search Result 1,317, Processing Time 0.034 seconds

A Large Scale Separation & Purification of Cyanobacterial Toxins (남조류 독성물질의 대량분리 및 정제)

  • Yoon, Suk Chang;Park, Keun Young;Pyo, Dong Jin
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.1
    • /
    • pp.51-56
    • /
    • 1998
  • It is very difficult to separate and purify the microcystins, cyanobacterial toxins since it exist in a trace level in natural lakes. In this paper, we developed a new analytical method to separate and purify the microcystin RR and LR from the freeze-dried cyanobacterial cells in natural lakes. We used 7.5 g silica gel as a stationary phase and ethyl acetate: isopropanol: water (30: 45: 25) as a mobile phase and microcystins were eluted using an open column. The eluting solvent was collected in a small bottle at the intervals of 3 mL and the fractions were chromatographed with HPLC to confirm the microcystin RR and LR.

  • PDF

A Study on the Wearing Comfort of Firefighter's Protective Clothing (한국 소방방수피복의 착용만족도 및 개선방안에 관한 조사연구)

  • Chung Jung-Sook;Lee Youn-Soon
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.12 s.142
    • /
    • pp.59-67
    • /
    • 1999
  • This study analyzed firefighter's actual wearing condition of turnout gear The results are as fellows: 1. When a firefighter is employed, Korea applies only the minimum of firefighters stature and weight but America applies both the minimum and the maximum. The choice of size is highly related with stature more than chest circumference. 2. The satisfaction degree of thermal barrier is very low, 3%. They used rubber gloves rather than heatproof gloves. This is more serious in small country like 'up', 'myun' than in cities. For laundering, they used sprinkling method with firefighting hose. Firefigthers hoped that their clothes could be classified tv the seasons and fire places. 3. frefighter had high unsatisfaction with the movement of hands and leges in the aspect of movement adjustability, air permeability, weight, body temperature regulation, and breathing in the hygenic aspect, fire resistance, thermal resistance property, water proof, chemical reactivity and electrical conductivity. Thev were also unsatisfied with water proof boots and gloves. They were generally satisfied with helmets but firefighters over 90kg of weight were rather unsatisfied. 4. The satisfaction degree for physical fitness was very low and the items with which they were not satisfied depend on physical features. 5. To develop turnout gear, they wanted changes in design, material and size. Reflection tape need to be replaced with high quality products and they wanted the use of velcro and zipper in fastening system.

  • PDF

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Design of an Organic Simplified Nuclear Reactor

  • Shirvan, Koroush;Forrest, Eric
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.893-905
    • /
    • 2016
  • Numerous advanced reactor concepts have been proposed to replace light water reactors ever since their establishment as the dominant technology for nuclear energy production. While most designs seek to improve cost competitiveness and safety, the implausibility of doing so with affordable materials or existing nuclear fuel infrastructure reduces the possibility of near-term deployment, especially in developing countries. The organic nuclear concept, first explored in the 1950s, offers an attractive alternative to advanced reactor designs being considered. The advent of high temperature fluids, along with advances in hydrocracking and reforming technologies driven by the oil and gas industries, make the organic concept even more viable today. We present a simple, cost-effective, and safe small modular nuclear reactor for offshore underwater deployment. The core is moderated by graphite, zirconium hydride, and organic fluid while cooled by the organic fluid. The organic coolant enables operation near atmospheric pressure and use of plain carbon steel for the reactor tank and primary coolant piping system. The core is designed to mitigate the coolant degradation seen in early organic reactors. Overall, the design provides a power density of 40 kW/L, while reducing the reactor hull size by 40% compared with a pressurized water reactor while significantly reducing capital plant costs.

Spud-can penetration depending on soil properties: Comparison between numerical simulation and physical model test

  • Han, Dong-Seop;Kim, Moo-Hyun
    • Ocean Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.107-120
    • /
    • 2017
  • Spud-can is used for fixing jack-up rig on seabed. It needs to be inserted up to the required depth during the installation process to secure enough soil reaction and prevent overturning accidents. On the other hand, it should be extracted from seabed soils as fast as possible during the extraction process to minimize the corresponding operational cost. To achieve such goals, spud-can may be equipped with water-jetting system including monitoring and control. To develop such a smart spud-can, a reliable numerical simulation tool is essential and it has also to be validated against physical model tests. In this regard, authors developed a numerical simulation tool by using a commercial program ANSYS with extended Drucker-Prager (EDP) formula. Authors also conducted small-scale (1/100) physical model tests for verification and calibration purpose. By using the numerical model, a systematic parametric study is conducted both for sand and K(kaolin)-clay with varying important soil parameters and the best estimated soil properties of the physical test are deduced. Then, by using the selected soil properties, the numerical and experimental results for a sand/K-clay multi-layer case are cross-checked to show reasonably good agreement. The validated numerical model will be useful in the next-stage study which includes controllable water-jetting.

DEVELOPMENT OF INTERFACIAL AREA TRANSPORT EQUATION

  • ISHII MAMORU;KIM SEUNGJIN;KELLY JOSEPH
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.525-536
    • /
    • 2005
  • The interfacial area transport equation dynamically models the changes in interfacial structures along the flow field by mechanistically modeling the creation and destruction of dispersed phase. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport mechanism for various sizes of bubbles, the transport equation is formulated for two characteristic groups of bubbles. The group 1 equation describes the transport of small-dispersed bubbles, whereas the group 2 equation describes the transport of large cap, slug or chum-turbulent bubbles. To evaluate the feasibility and reliability of interfacial area transport equation available at present, it is benchmarked by an extensive database established in various two-phase flow configurations spanning from bubbly to chum-turbulent flow regimes. The geometrical effect in interfacial area transport is examined by the data acquired in vertical fir-water two-phase flow through round pipes of various sizes and a confined flow duct, and by those acquired In vertical co-current downward air-water two-phase flow through round pipes of two different sizes.

The Development of an Event Rainfall-Runoff Model in Small Watersheds (홍수 사상에 대한 소유역 강우-유출 모형 개발)

  • 이상호;이길성
    • Water for future
    • /
    • v.27 no.3
    • /
    • pp.145-158
    • /
    • 1994
  • The linear reservoir rainfall-runoff system was developed as a rainfall-runoff event simulation model. It was achieved from large modification of runoff function method. There are six parameters in the model. Hydrologic losses consist of some quantity of initial loss and some ratio of rainfall intensity followed by initial loss. The model has analytical routing equations. Hooke and Jeeves algorithm was used to model calibration. Parameters were estimated for flood events from '84 to '89 at Seomyeon and Munmak stream gauges, and the trends of major parameters were analyzed. Using the trends, verifications were performed for '90 flood event. Because antecedent fainfalls affect initial loss, future researches are required on such effects. The estimation method of major parameters should also be studied for real-time forecasting.

Experimental and Numerical Methods for Thermal Conductivity of Backfill Soils for Subsea Pipeline (해저배관 뒤채움 흙의 열전도율 산정에 관한 실험 및 수치 해석적 연구)

  • Park, Dong-Su;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.103-110
    • /
    • 2017
  • The temperature of subsea pipeline, approximately as high as $100^{\circ}C$, is significantly higher than the temperature of surrounding sea water and sediment. In this reason, heat can be lost from the subsea pipeline to cause serious operation problem. Therefore it is important that the subsea pipeline must be designed to ensure that heat loss is small enough. Heat loss of unburied pipeline is higher than buried pipeline. For that purpose, trenching and backfilling system is a commonly used method for maintaining flow assurance in subsea pipeline installation. For this commonly used method, knowing thermal conductivity of backfill is essential to protect a heat loss of pipeline. This paper presents thermal conductivity of backfill soil using laboratory model test and numerical analysis for various backfill. In conclusion, it can be seen that higher the sand content of the man-made backfill sample, the higher the thermal conductivity. On the other hand, as the water content increases, the thermal conductivity becomes smaller.

서울시 지하철구간내 지하수위강하에 따른 지하공간 환경오염 감시의 필요성 및 대책

  • 이기철;김윤영;이주영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.167-172
    • /
    • 2002
  • Seoul subway system has been constructed to solve traffic difficulties of Seoul metropolitan, and now is the major public transportation. However, the more line has added in the system the deeper the bottom of the tunnel base. And a huge amount of groundwater along the line has seeping into the tunnel. Several subway stations has pumping system to extract the groundwater to the outside and consequently, groundwater table along the line has declined gradually. Groundwater table has dropped about 40 meters at some areas, There was some study for the proper usage of the abstracted groundwater and the project to use the groundwater has launched already by the local government. However. more serious problem is expected on quality degradation of soil and groundwater as the decline of groundwater table along the subway line. This study suggests that the detailed groundwater environmental study should be made as soon as possible for this. If there is any pollution leaking at the surface area of the groundwater depression, the pollution will be seep into the subway tunnel in some day even though the time will be different with the soil material and hydraulic characteristics of the aquifer. And the polluted area of the soil and groundwater would be enlarged along the pathway The study on possibility of the soil subsidence and reducing surface water flow in small creek were also needed. This study suggest one of the counter measurement that restoring the declined groundwater table after groundwater environmental study

  • PDF

A Framework for Investment Justification and Economic Operation- (한국의 다목적댐 수력발전 체계-투자의 정당화와 경제적 운영-)

  • 이승규;박용삼
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.12 no.1
    • /
    • pp.157-157
    • /
    • 1987
  • Hydro-electric power generation from multi-purpose dams has been playing important roles in the electric power supply network in Korea. Although the total share of hydro power in national electricity supply now becomes very small, the peak-shaving and frequency control capability of hydro power helps the power company enormously in maintaining the quality of power. But since the company that builds and operates the multi-purpose dams in Korea has to sell all the electricity produced to the monopolistic utility, there have been various problems in justifying the investment, designing pricing mechanism, and controlling operations of the power plants. In addition, economic evaluation of the hydro power has been distorted by a variety of reasons and hence it has been very difficult to encourage effective development and utilization of national water resources. To make the problem worse, both parties are public companies with X-inefficiency problems. Thus, changing environment requires to reengineer the system that governs hydro power generation. We address the problems of Korean hydro-electric power generation system in four areas: the investment justification process, the operations decison right of the hydro power plants, the pricing of the purchased-power, and the negotiation of contract revision. Then we propose improvement directions of new hydro-electric power system in view of static and dynamic efficiency, X-inefficiency and equity.