• 제목/요약/키워드: small water system

검색결과 1,317건 처리시간 0.035초

세종의 자격루 : (2)자격보시장치 (The King Sejong′s String Clepsydra: (2) Bay and Night Time Announcing System)

  • 남문현;서문호;한영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.702-706
    • /
    • 1996
  • The King Sejong's Striking water-clock was named for its distictive day and night time announcing system. Its time announcing system generates acoustic and visual signals for the twelve double hour, and combinations of two different acoustic signals for the five night watches, The mechanism of this signal generation system is triggered by a copper ball which is mechanically digitized time keeping signal, and is generated from the water clock. The time announcing system consisted four parts: 1) the mechanical amplifier which changes small copper to heavy steel ball, 2) day time announcing system, 3) night time announcing system, 4) sounding mechanism. The time announcing system of King Seong's Striking Clepsidra is remotely related to the Arabic clock system, however, it does have world-widely distictive mechanisms of its era, such as mechanical amplifier, self-weight rachet mechanism, and resetable mechanical computer etc.

  • PDF

소형 암모니아 흡수식 냉난방기의 난방성능 특성 (The Characteristics of Heating Performance on Small Sized Ammonia Absorption System)

  • 진병주;오승택;윤정인;황준현;진심원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.120-123
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

소형 암모니아 흡수식 냉난방기의 냉방성능 특성 (The Characteristics of Heating Performance on Small Sized Ammonia Absorption System)

  • 진병주;오승택;윤정인;황준현;진심원;경익수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.198-202
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발 (Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant)

  • 조병옥;박철원
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.

소규모수도시설 지하수의 라돈저감 특성 (Characteristics of Radon Reduction of Small-scale Water Supply System)

  • 조병욱
    • 지질공학
    • /
    • 제29권1호
    • /
    • pp.37-50
    • /
    • 2019
  • 지하수를 원수로 이용하는 소규모수도시설의 라돈 저감은 주로 저수조에서의 정치와 폭기에 의해 일어난다. 여름철 정치에 의한 32개 소규모수도시설 저수조와 꼭지수의 라돈 저감율은 -69.3~62.7%(평균 25.7%)와 -64.3%~83.1%(평균 30.3%), 가을철 정치에 의한 16개 소규모수도시설 저수조와 꼭지수의 라돈 저감율은 21.3%~78.0%(평균 42.8%)와 17.7%~66.9%(평균 44.8%)로 나타났다. 여름철보다 가을철의 라돈 저감률이 더 높은 것은 가을철의 지하수 사용량이 더 적어서 정치효과가 더 컸기 때문으로 판단된다. 폭기시설이 설치된 12개 저수조의 라돈 저감률은 47.4~94.0%(평균 78.9%)로 나타났는데 이 저감률에는 정치에 의한 라돈 저감률이 합쳐져 있다. 소규모수도시설 지하수의 라돈 저감을 위해서는 정치와 폭기를 이용할 수 있는데 보다 효율적인 활용을 위하여 지하수의 라돈 함량 변동성, 저수조의 크기와 형태, 지하수 사용량 변화, 폭기량, 환기시설 등을 고려한 라돈 저감 연구가 필요하다.

$\small{D}$-Lactic Acid Production by Sporolactobacillus inulinus Y2-8 Immobilized in Fibrous Bed Bioreactor Using Corn Flour Hydrolyzate

  • Zhao, Ting;Liu, Dong;Ren, Hengfei;Shi, Xinchi;Zhao, Nan;Chen, Yong;Ying, Hanjie
    • Journal of Microbiology and Biotechnology
    • /
    • 제24권12호
    • /
    • pp.1664-1672
    • /
    • 2014
  • In this study, a fibrous bed bioreactor (FBB) was used for $\small{D}$-lactic acid ($\small{D}$-LA) production by Sporolactobacillus inulinus Y2-8. Corn flour hydrolyzed with ${\alpha}$-amylase and saccharifying enzyme was used as a cost-efficient and nutrient-rich substrate for $\small{D}$-LA production. A maximal starch conversion rate of 93.78% was obtained. The optimum pH for $\small{D}$-LA production was determined to be 6.5. Ammonia water was determined to be an ideal neutralizing agent, which improved the $\small{D}$-LA production and purification processes. Batch fermentation and fed-batch fermentation, with both free cells and immobilized cells, were compared to highlight the advantages of FBB fermentation. In batch mode, the $\small{D}$-LA production rate of FBB fermentation was 1.62 g/l/h, which was 37.29% higher than that of free-cell fermentation, and the $\small{D}$-LA optical purities of the two fermentation methods were above 99.00%. In fe$\small{D}$-batch mode, the maximum $\small{D}$-LA concentration attained by FBB fermentation was 218.8 g/l, which was 37.67% higher than that of free-cell fermentation. Repeate$\small{D}$-batch fermentation was performed to determine the long-term performance of the FBB system, and the data indicated that the average $\small{D}$-LA production rate was 1.62 g/l/h and the average yield was 0.98 g/g. Thus, hydrolyzed corn flour fermented by S. inulinus Y2-8 in a FBB may be used for improving $\small{D}$-LA fermentation by using ammonia water as the neutralizing agent.

LAND FARMING OF WATER PLANT ALUM SLUDGE ON ACID MINERAL SOIL AFFECTED BY ACID WATER

  • Lee, Seung-Sin;Kim, Jae-Gon;Moon, Hi-Soo;Kang, Il-Mo
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.182-186
    • /
    • 2001
  • An acid forest surface soil as a land farming medium was treated with a water plant alum sludge at 0 to 18%. Indian mustard was grown in the treated soil in a greenhouse for 5 weeks and watered with pH 4 tap water adjusted with a mixed acid (1HNO$_3$: 2H$_2$SO$_4$) during plant growth. Changes in soil property, leachate chemistry, plant growth, and plant uptake of elements by the sludge treatment were determined. The alum sludge treatment increased buffer capacity to acidity, hydraulic conductivity, water holding capacity, and phosphate adsorption of the soil and decreased bulk density and mobility of small particles. The sludge treatment reduced leaching of Al, Mg, K, Na, and root elongation. Plant did uptake less amount of the cations and P but more Ca with the sludge treatment.

  • PDF

이동식 미분무수 소화장비의 소화능력 향상에 관한 연구 (A Study on Improving Extinguishing Capacity of Mobile Water Mist Equipment)

  • 공하성;김종진
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.15-26
    • /
    • 2009
  • This research has so far found out problems including the second damage of extinguishant and the short time of emission when using the existing dry chemical extinguisher and gas type extinguisher, and impossibility of constant extinguishing due to the inability of recharge at the field. To solve such problems, a mobile water mist system was developed and used. However, it is judged that more improved mobile water mist system is necessary because the force of the fire changed diversely and remote villages in mountains or islands where the force of fire extinguishing is short or delayed, require high capacity of fire extinguishing. Therefore a new equipment was developed and tested focusing on the improvement of extinguishing capacity and the performance of extinguishing was found out to be improved, compared to the existing mobile water mist system. It also showed a superior extinguishing capacity to dry chemical extinguisher or gas type extinguisher. Afterward an additional research is required of simplification of equipment, price cutting and the development of additive to enable high performance even with just small extinguishant.

Development of an on-demand flooding safety system achieving long-term inexhaustible cooling of small modular reactors employing metal containment vessel

  • Jae Hyung Park;Jihun Im;Hyo Jun An;Yonghee Kim;Jeong Ik Lee;Sung Joong Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2534-2544
    • /
    • 2024
  • This paper proposes a flooding safety system (FSS) and its operation strategy that can provide long-term safety and effective maintenance for modules of small modular reactor (SMR) and metal containment maintained at dried environment during normal operation. During hypothesized accidents, the FSS re-collects the evaporated steam into the common pool by the condenser installed above the common water pool and provides an emergency coolant for the cavities and auxiliary pools. This study suggested that the condensate re-collection strategy using the FSS can effectively delay the depletion of available water in response to the accidents. Without recollection, the achievable grace periods ranged from 44 to 1507 days for six-module and one-module accidents, respectively. However, with a full re-collection (ratio = 1.0), the time to total depletion of emergency coolant was estimated indefinite. Even with a partial re-collection ratio of 0.3, a grace period of 83.5 days could be ensured for a six-module transient. This study reported the effectiveness of condensate re-collection and the FSS as an innovative safety management strategy and system. Employing a condensate re-collection strategy with a high re-collection ratio can enhance the long-term safety and effective convenience of SMR operations and maintenance.

모세구동 소형 냉각시스템의 실험적 연구 (An Experimental Study on Small Capillary Pumped Cooling System)

  • 양재경;이규정;이정현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.234-239
    • /
    • 2000
  • The capillary pumped cooling system (CPCS) is a cooling system which controls temperature of the small electronic devices, such as IC device systems, notebook computers, etc. An important feature of CPCS is that a working fluid circulates in a system by capillary force in tubes instead of mechanical input power. The cooling effect of CPCS is investigated with respect to heat flux, condensation temperature under different working fluids (water, ethanol, methanol). Capillary pumped flows are visualized under various conditions and mass flow rate and temperature are experimentally measured. It is shown that the increasing tendency of mass flux for each working fluid is observed as the temperature of evaporator increases, and that the cooling possibility of CPCS depends on the performance of evaparator and condenser which sustains the steady state temperature continuously.

  • PDF