• 제목/요약/키워드: small water system

검색결과 1,317건 처리시간 0.025초

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

  • Hossam H. Abdellatif;Palash K. Bhowmik;David Arcilesi;Piyush Sabharwall
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2375-2387
    • /
    • 2024
  • The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

미나리와 돌미나리의 돌연변이 유발 억제작용과 항산화 효과 (Antimutagenic and Antioxidative Effects of Water Dropwort and Small Water Dropwort)

  • 이경임;이숙희;박건영
    • 한국지역사회생활과학회지
    • /
    • 제15권1호
    • /
    • pp.49-55
    • /
    • 2004
  • The purpose of this study is to research the antimutagenic and antioxidative effects of water dropwort and small water dropwort by Ames test and by measuring malondialdehyde(MDA) production. Water dropwort and small water dropwort were extracted with methanol and then further fractionated to hexane, chloroform, ethyl acetate, butanol and water, stepwise. The methanol extracts from both samples reduced the mutagenicities by aflatoxin $B_1(AFB_1)$ in Salmonella typhimurium TA 98. The production of MDA also decreased when the methanol extracts were added to the system. The hexane, chloroform and ethyl acetate fractions revealed higher antimutagenic activities against $AFB_1$ than the butanol and water fractions. Among the five fractions, the ethyl acetate fraction showed the highest level of antioxidant activity. From the results of the experiment, water dropwort and small water dropwort seem to be good antimutagenic and antioxidative sources of food.

  • PDF

영산강IV지구 농업용수 통합관리시스템 개발 (Development of the Irrigation Water Management System in Yongsan river Fourth District)

  • 주욱종;김진택;박재흥
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1238-1241
    • /
    • 2004
  • Yongsan river 4th agricultural comprehensive development project is being developed in order to strengthen the competitiveness in the southwest sea-side district, to construct the area for the special product and so on. Different from other development project, this project is to use water from its watershed by means of using regulating reservoirs, small reservoirs and farm ponds. but the number or regulating reservoirs, small reservoirs and farm ponds involved in this project are 7, 147 and 13 respectively. So it is necessary to develope the irrigation water management system for the purpose of efficient water use in Yougsan river fourth district. In this study, the irrigation water management system was developed and by using this system. efficient water using plans could be established.

  • PDF

소규모수도시설의 보안시설 설치지침 개발 (Development of Guidelines for Physical Security Systems of Small-scale Water Supplies)

  • 김영일;이상진;이두진;이원태
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안 (The Optimum Control Study for Improving Efficiency of the small hydropower generation in water pipe)

  • 홍정조;임동희;김수상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.126-129
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with Sung-Nam and Bo-Ryong small hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

소형 건축 벽면의 냉수 패널에 의한 냉방시스템에 관한 연구 (A Study on Cooling Systems with Cold Water Panels in the Walls of Small Buildings)

  • 조동현;조명기
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.20-26
    • /
    • 2019
  • This study was conducted on cooling systems in which, for the first time at home and abroad, cold water panels are embedded in the walls of small buildings for radiant cooling by heat absorption with cold water. In summer, cold water is circulated through cold water (chiller) circulation tubes embedded in three walls (two side walls and one rear wall) of a building to implement radiant cooling by the coldness of the water. From the results of this study, the experimental and theoretical natural convection heat transfer coefficients were relatively well-matched over the entire experimental range, thereby verifying the reliability of the experimental results. The surface temperature reduction rate of the walls in which cold water panels are embedded was large whereas that of the walls where no cold water panels are embedded was very small.

농촌지역 소규모 소택형습지의 유형분류 및 기능평가 연구 (The Type Classification and Function Assessment at Small Palustrine Wetland in Rural Areas)

  • 손진관;김남춘;강방훈
    • 한국환경복원기술학회지
    • /
    • 제13권6호
    • /
    • pp.117-131
    • /
    • 2010
  • This study was conducted to utilize as basic information for the construction of conservation and estimation system for Palustrine wetland, which was badly managed and imprudently reclaimed, through the analysis of distribution characteristics and the estimation of conservation value for sample sites (eight wetlands) in rural area. As the result of wetland type classification, these wetlands was classified by 4 types (Permanent freshwater marshes/pools, ponds, Aquaculture ponds, and Seasonally flooded agricultural land) by Ramsar system, 3 types (Emergent Wetland, Aquatic Bed, and Scrub-Shrub Wetland) by NWI (Cowardin) System, 5 types (Farm Pond Depression, Under-flow wetland, Man-made Pond Depression, Abandoned Paddy Fields Wetland, and Reservoir Shore) by National Wetland's Categorical System, and 3 types (Aquatic Bed Wetland, Emergent Wetland, and Forested Wetland) by Lee (2000) System. These results suggest us developing the new type classification system for small Palustrine wetland in Korean rural areas. The score of function assessment (The Modified RAM) for small Palustrine wetlands was high at the wetlands nearby hills and rice paddy fields, and low at those nearby upper fields, which was mainly affected by land-use and vegetation. The functions as 'Flood/Storm Water Storage', 'Runoff Attenuation', 'Water Quality Protection' were resulted by the structural difference of inflow and outlet. Some functions as 'Wetland size', 'Wetland to immediate watershed ratio', 'Presence of boat traffic', 'Maximum water depth', 'Fetch of water's body' of RAM were not appropriate in evaluation of small wetlands in rural area. Which suggest us developing the new function assessment system for small Palustirne wetland in Korean rural areas.

통합 수질계측 시스템 개발 (A development of integrated water-quality measurement system)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제8권3호
    • /
    • pp.211-216
    • /
    • 2007
  • 대형 정수장에서 개인수도꼭지까지 전체 급수 설비에서 수질은 반드시 먹는 물 수질기준을 만족해야 한다. 그러나 현재까지도 수돗물의 공급과정은 과학적으로 모니터링 되거나 관리되지 못하고 있다. 수돗물 특히 대부분의 작은 규모의 정수장은 항상 다양한 오염원 및 불순물 등에 노출되어 있다. 최근 일부 대형 정수장이나 배수지 등에 수질감시 시스템이 사용되고 있다. 특히 인터넷을 이용한 수질 모니터링 방법이 일부 지방자치단체에 도입되었으며 이 시스템은 해당 지역주민들이 언제 어디서나 수질을 확인할 수 있도록 되어있다. 그러나 이 시스템, 즉 대형 시스템에 사용되는 이 방법은 매우 높은 비용을 필요로 하고 이로 인해 아파트, 공공시설, 소규모의 지하저수조 및 고가(高架)저수조와 같은 소규모 급수설비에는 적용하기가 곤란하다. 따라서 본 연구에서는 저가의 개별 수질측정 센서모듈에 대한 통합시스템을 제안한다. 개발된 통합 시스템과 인터넷상에서 동작하는 모니터링 프로그램을 이용하여 저수조 시스템 관리자는 음용수에 대한 수질 특성치를 실시간으로 관리할 수 있다. 또한 제안된 시스템이 모듈화 되어있기 때문에 크고 작고의 규모에 관계없이 저비용으로 다양한 저수조나 정수장에 쉽게 설치할 수 있다.

  • PDF

침지형 다항목 수질계측기 및 원격 모니터링 시스템 개발 (A development of submerged type multiprobe water-quality measuring instrument and remote monitoring system)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제10권3호
    • /
    • pp.207-213
    • /
    • 2009
  • 정수장에서 수도꼭지까지 전체적인 물 공급 체계에서 수돗물의 수질은 먹는 물 기준에 적합해야 하지만 수돗물 공급과정에서 수질 모니터링과 충분한 관리가 이루어지지 않고 있다. 특히 대부분의 소규모 저수조(지하저수조 또는 고가(高架)저수조)의 수도관은 다양한 오염원에 노출되어 있다. 최근의 수질 모니터링 시스템은 몇몇 대형 정수장과 배수지 등에 설치되어 운영하고 있다. 특히 인터넷을 이용한 수질 모니터링은 언제 어디서나 주민들이 확인할 수 있도록 몇몇 지방자치단체에서 채택하고 있다. 이러한 시스템을 구축하는 것은 대규모 시설을 필요로 하기 때문에, 아파트, 공공건물, 소규모 지하저수조 또는 고가저수조와 같은 규모가 적은 물 공급시설에는 제한적으로 적용된다. 본 연구에서는 저렴한 각각의 수질센서 모듈을 집적화하여 개발한 다항목 수질계측기를 이용하여 인터넷에서 운용되는 온라인 모니터링 프로그램을 개발하였다. 저수조 관리자는 온라인으로 먹는 물의 수질 측정값을 모니터링할 수 있다. 제안된 다항목 수질측정기를 집적화하였으며, 저수조의 크기와 관계없이 저가로 다양한 저수조에 쉽게 적용할 수 있는 시스템이다.

  • PDF

소수력 발전설비의 성능시험센터 구축 (Establishing performance test center for a small hydropower)

  • 김영준;김상균;이동근;박주영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.660-663
    • /
    • 2009
  • Currently in Korea, the lack of facilities and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic small hydropower turbine, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore Korean institute of water and environment in K-water planned making a basis of performance test of small hydropower by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system. Improving the efficiency of small hydropower system can achieve the additional development benefit about 1.5 billion won per year.

  • PDF