• 제목/요약/키워드: small water system

Search Result 1,317, Processing Time 0.032 seconds

Automatic Distress Notification System Working with an External VHF Device in Small Ship (비상재난 발생 시 외부 VHF 장비와 연동하는 소형선박용 재난자동속보장치)

  • Jeong, Heon
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • In this paper, I have developed an automatic distress notification system (ADNS) working with an external VHF device in small ship. The proposed system is as part of a small ship disaster analysis system which can detect and quickly respond to the small ship disaster. The automatic notification system receives the location information signal from the disaster analysis system, and the signal will be converted into voice signal to broadcast of the accident position through external VHF device. It will be sending a distress message as form of voice information through VHF device until sinking under the water. Through this research, I expect we'll be make a quick response and prevent a terrible loss of human life.

A Development of Integrated Control System for Platform Equipments of Unmanned Surface Vehicle (USV) (무인수상정 플랫폼 장비의 통합 제어 시스템 개발)

  • Hwang, Hun-Gyu;Kim, Hyun-Woo;Kim, Bae-Sung;Woo, Yun-Tae;Shin, Il-Sik;Shin, Ji-Hwan;Lee, Young-Jin;Choi, Byung-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1611-1618
    • /
    • 2017
  • Recently, the development for USV-related technologies are actively growing up in military domain. The USV (unmanned surface vehicle) conducts various missions for national defense at maritime environment. For succeed the missions, the USV essentially needs an automatic and remote control platform which includes propulsion system, steering system, control system, power system and so on. In this paper, we developed an integrated control system for the platform equipments and verified effectiveness of the developed system. To do this, we designed a system architecture and implemented a main control system that processes and controls platform equipments by received command. Also we developed components of designed architecture such as engine control device, water-jet control device and power control device. For test and verify the developed system, we designed and made a test-bed of engine and water-jet with related parts, and proceeded a basin test for verifying the developed system based on the test-bed.

A Study on the Solar Water Heating System in the Military Facilities (병영시설의 태양열급탕시스템에 관한 연구)

  • Kim, Doo-Chun;Seo, Jin-Seok
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.4
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses (공동주택용 태양열원 급탕시스템의 운전성능 연구)

  • 이윤규;황인주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

Waterproof Characteristic for Environmental Water Flows in Small Streams (소규모 하천 친환경 물흐름을 위한 차수특성)

  • Park, Min-Cheol;Kim, Seong-Goo;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.192-199
    • /
    • 2010
  • This research produced internal model tester ($2.0m{\times}2.0m{\times}1.0m$) to evaluate the field application of Paju Unjeong District water recycling system for small streams eco-friendly river bed disparity method for the first time in Korea and conducted comparative analysis of the Paju Unjeong District water recycling system field test results and infiltration rate result of internal tests by each rainfall intensity following surface material. Infiltration rate result of internal tests concrete pavement by rainfall intensity following surface material, asphalt pavement, bentonite mate, stabilized soil construction and mixed soil construction manifested low infiltration rate. On the contrary, compaction soil, grassland and water permeable packaging materials resulted in significant amount of infiltration rate. As for the field permeability test results, they were manifested similar tendency as indoor permeability test results and they satisfied the standard for standard of water permeability of domestic disparity facility (less than $1.0{\times}10-7cm$/sec). As compaction rate increased, unconfined compression strength increased as well while coefficient of water permeability decreased.

  • PDF

Development of Water Quality Management Model for Rural Area Using Decision Support System (의사결정지원기법을 이용한 농촌유역 수질관리모형의 개발)

  • 양영민;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.783-788
    • /
    • 1999
  • In this study, a decision support system (DSS) was developed to calculate optimal wastetreatment cost, treatment level and treatment quantity of various pollutants for applying for in rural basin. The DSS includes a gegraphic informatino system (GIS), relational database system (RDBS), water quality models(Loading function , WASP5), watershed pollution load calculation module(SPLC), optimal water quality management plan to satisfy the water quality regulations. The system can be modified by user to trace the optimal condition for decision. The effort was conducted to apply the developed DSS to select the for optimal water quality management plan small rural basin called Kwanri Stream.

  • PDF

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

Prediction of Motion State of a Docking Small Planing Ship using Artificial Neural Network

  • Hoang Thien Vu;Thi Thanh Diep Nguyen;Hyeon Kyu Yoon
    • Journal of Navigation and Port Research
    • /
    • v.48 no.2
    • /
    • pp.116-124
    • /
    • 2024
  • Automatic docking of small planing ship is a critical aspect of maritime operations, requiring accurate prediction of motion states to ensure safe and efficient maneuvers. This study investigates the use of Artificial Neural Network (ANN) to predict motion state of a small planing ship to enhance navigation automation in port environments. To achieve this, simulation tests were conducted to control a small planing ship while docking at various heading angles in calm water and in waves. Comprehensive analysis of the ANN-based predictive model was conducted by training and validation using data from various docking situations to improve its ability to accurately capture motion characteristics of a small planing ship. The trained ANN model was used to predict the motion state of the small planning ship based on any initial motion state. Results showed that the small planing ship could dock smoothly in both calm water and waves conditions, confirming the accuracy and reliability of the proposed method for prediction. Moreover, the ANN-based prediction model can adjust the dynamic model of the small planing ship to adapt in real-time and enhance the robustness of an automatic positioning system. This study contributes to the ongoing development of automated navigation systems and facilitates safer and more efficient maritime transport operations.

A Water Environment Management and Evaluation Systems for a Small Watershed (II) - Operation and Applications - (소유역에서의 수계환경관리 및 평가시스템의 개발(II) - 시스템의 운용과 적용 -)

  • Kang, Moon-Seong;Park, Seung-Woo;Her, Young-Gu
    • Journal of Korean Society of Rural Planning
    • /
    • v.7 no.1 s.13
    • /
    • pp.15-25
    • /
    • 2001
  • This paper described the overall operations and applications of the water environment management and evaluation systems (WEMES) for environmental management, conservation, and evaluation for a small watershed. WEMES was to be applied with field data from small watersheds ranging from 0.4 to 29.79km2 in size which have steep topography and complex landuses. WEMES was a computer aided decision support system, that was comprised of the database subsystem, the simulation model subsystem, the environmental evaluation model subsystem, and the graphic user interface subsystem that visualizes the simulated results. The water environment management and evaluation with WEMES was successfully performed.

  • PDF

Overview and Trend of Small Hydropower Development in Korea (국내 소수력 발전 기술현황과 전망)

  • Lee, Gyeong-Bae;Kim, Young-Gue;Paik, Doo-Hyun;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.762-764
    • /
    • 2003
  • In Korea, over 97% of local energy demand is imported from other countries. And we have to lift the energy independence level up to 5% with replacement energy (renewable energy) such as solar, small hydropower, etc. by 2011 according to the energy agreement made in Kyoto Protocol. So, we proposed some opinions such as the better improvement of small hydropower industry the people' view, cooperation among industry/university/research institutes, remote control/maintenance and goverment's legislature and supporting system etc.

  • PDF